asbestos survey report - BBI Projects

Report 0 Downloads 40 Views
ASBESTOS SURVEY REPORT

Southwest Tower Apartment (ID: Alice) SOUTHWEST TOWER APARTMENTS 1501 Alice Street Oakland, CA 94612

Prepared for: CHRISTIAN CHURCH HOMES 1501 Alice Street Oakland, CA 94612

Prepared by: ACC Environmental Consultants, Inc. November 20, 2009 Project Number: 1299-005.00 Prepared By:

Matt Chin a California Certified Asbestos Consultant Cal/OSHA #08-4332

Reviewed By:

Mark A. Sanchez a California Certified Asbestos Consultant Cal/OSHA #92-0082

Table of Contents Section: Executive Summary 1

Introduction

2

Description of Building Construction and Systems

3

Summary of Findings for Suspect Materials

4

Material Information Tables

5

Removal Cost Estimate Summary

Appendices: A

Definitions of Terms and Assessment Criteria

B

Bulk Sampling Protocol and Analytical Methods

C

Laboratory Bulk Sampling Reports

D

Summary of Regulatory Requirements

Executive Summary ACC Environmental Consultants, Inc. (ACC) was retained by Christian Church Homes to perform an Asbestos Hazard Emergency Response Act (AHERA) style asbestos survey of the Southwest Tower Apartment (Building ID: Alice), to determine the locations of accessible and to the extent feasible, inaccessible friable and non-friable asbestos containing building materials (ACBM). Friable materials are materials that can be reduced to powder with hand pressure such as fireproofing, sprayed-on acoustic ceilings, ceiling tile, pipe insulation, and other thermal systems insulation. All other materials such as floor tile, adhesives, plaster, stucco, and sheet rock mudding compounds are considered non-friable materials. Because friable materials are more likely to release asbestos fibers into the air when disturbed than non-friable materials, friable materials are considered a greater health concern. No friable asbestos-containing materials were observed in the building. Asbestos was detected or assumed in the following non-friable materials: Ceramic Tile Underlayment Floor Tile And Adhesive Sheet Vinyl Flooring Tile Grout

Site ID: Alice Building ID: Alice Southwest Tower Apartment Asbestos Survey Report

Executive Summary Page

1

Section 1 Introduction ACC Environmental Consultants, Inc. (ACC) performed an Asbestos Hazard Emergency Response Act (AHERA) style asbestos survey of the Southwest Tower Apartment located at 1501 Alice Street, Oakland, CA, to identify ACBM. This report identifies the locations and asbestos content of friable and non-friable ACBM, provides assessment of the friable ACBM in relation to the material's hazard potential to building occupants and provides removal cost estimates. Friable materials are materials that can be reduced to powder with hand pressure such as fireproofing, sprayed-on acoustic ceilings, ceiling tile, pipe insulation, and other thermal systems insulation. All other materials such as floor tile, adhesives, plaster, stucco, and sheet rock mudding compounds are considered non-friable materials. Because friable materials are more likely to release asbestos fibers into the air when disturbed than non-friable materials, friable materials are considered a greater health concern. All identified suspect asbestos-containing materials are summarized in Section 3. Materials testing positive for asbestos including material assessments, recommended response actions, and quantities are described in Section 4. Removal cost estimates are for budgeting purposes only and should not be used as a quote for removal of the materials. It is not our recommendation to remove these materials unless they are beyond repair, or planned demolition or renovation activities will disturb the materials. Estimates are based on recent pricing we have received from contractors performing similar work and may vary from actual prices obtained due to the actual scope of work, quantity of material removed, control measures specified and contractor work loads. On Monday, November 9, 2009, Matt Chin (Cal/OSHA #08-4332), a California Certified Asbestos Consultant, from ACC, performed an asbestos survey of the building(s) in accordance with the Asbestos Hazard and Emergency Response Act of 1987 (AHERA). DISCLAIMER This report is prepared for the express use and benefit of Christian Church Homes, its agents and employees. The information in this report or portions thereof may be required to be included in notifications to employees, contractors or other visitors to the building(s). This report is not intended to be used as a specification or work plan for any of the work suggested or recommended in this report. This report is based upon conditions and practices observed at the property and information made available to the surveyor. This report does not intend to identify all hazards or unsafe practices, nor to indicate that other hazards or unsafe practices do not exist at the premises. ACC made their best effort to determine the location of inaccessible ACBM. ACC shall not be responsible for identifying all ACBM located behind walls and/or columns, beneath flooring, above solid ceilings, underground or any other inaccessible areas.

Site ID: Alice Building: Southwest Tower Apartment Asbestos Survey Report

Section 1 Page

1

Section 2 Description of Building Construction and Systems Number of Floors: 9

Year Built: 1978

Total Square Footage: Structural components consist of: Concrete Foundation Exterior Wall construction components consist of: Concrete Stucco Interior Wall construction components consist of: Drywall Concrete Interior ceiling components consist of: Ceiling Tile Drywall Roofing construction components consist of: Tar&Felt Heating and mechancial systems include: Boilers Ducted Supply

114,000

Building Description/Comments: Eight story apartment building containing 130 units. Ground floor contains the building office, social hall, commercial kitchen, rental units, maintenance shop, storage, compactor, and laundry rooms. Floors two through eight contain rental units. The boiler for the building is located on the 9th floor (roof). Comments: 1. ACC surveyed 16 representative units and all common areas. 2. ACC surveyed the exteriors and roofs of all buildings and carports. 3. Asbestos containing materials identified in units/areas inspected may be found in other units/areas at the complex. 4. Additional suspect asbestos containing materials not identified in this report may be found in units/areas not inspected.

Site ID: Alice Building: Southwest Tower Apartment Asbestos Survey Report

Section 2 Page

1

Section 3 Summary of Findings for Suspect Materials The following table is a list of all materials at this building which were tested for the presence of asbestos or were assumed to contain asbestos along with overall sample results. Complete information on asbestos containing materials is included in Section 4 of this report. Each unique material within the building is assigned a unique HM number by the surveyor at the time the survey is performed. Section 3 and Section 4 are organized by building, surfacing, thermal systems insulation, flooring, walls, ceilings, roofing and miscellaneous materials. Site Information

Client Information

Southwest Tower Apartment (Site ID: Alice) 1501 Alice Street Oakland, CA 94612

Christian Church Homes 1501 Alice Street Oakland, CA 94612

Survey Performed By

Inspector

Inspection Date

Job Number

ACC Environmental Consultants, Inc.

Matt Chin

Monday, November 9, 2009

1299-005.00

Suspect Material

Category

HM Number

Material Location(s)

Asbestos Present?

Orange Peel Wall Texturing Compound

Surfacing

WT-1

Walls in Units and Hallways Floor(s): 1-8

No

Acoustical Ceiling Material

Surfacing

SA-2

Ceilings in Units and Social Hall Floor(s): 1-8

No

Drywall And Joint Compound

Miscellaneous

JC-3

Wall throughout Building and Ceilings in Kitchen and Bathrooms on 1st Floor and other possible areas of building. Floor(s): 1-8

No

Miscellaneous

FA-4

Floors in Kitchens and Bathrooms of Units Yes 108, 109, 201, 203, 305, 404, 417, 504, 516, 613 and other possible units not inspected. Floor(s): 1-6

Brown Baseboard and Baseboard Miscellaneous Adhesive (Brown)

BA-5

Walls of 1st Floor and Units: 108, 109, 201, No 203, 306, 404, 417, 504, 516, 613, 617, 704, 705, 707, 801, 818 and other possible units not inspected. Floor(s): 1-8

2’x2’ Pinholed Ceiling Tile

Miscellaneous

CT-6

Kitchen Ceilings in Units: 108, 109, 201, 203, No 306, 404, 417, 504, 516, 613, 617, 704, 705, 707, 801, 818 and other possible units not inspected. Floor(s): 1-8

Beige Sheet Vinyl Flooring

Miscellaneous

SV-7

Kitchen and Bathroom Floors of Units: 617, 704, 707, 801, 818 and other possible units not inspected. Floor(s): 6-8

No

12”x12” Red/Orange Streaked Floor Tile And Adhesive (Black)

Miscellaneous

FA-8

Social Hall and Kitchen Pantry. Floor(s): 1

Yes

12”x12” Beige Floor Tile And Adhesive (Yellow)

Section 3 Summary of Findings for Suspect Materials Page 1 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

November 9, 2009

Suspect Material

Category

HM Number

Red Mosaic Sheet Vinyl Flooring

Miscellaneous

SV-9

Rear Entry near Kitchen and other possible areas of building Floor(s): 1

Yes

2’x4’ Fissured Ceiling Tile

Miscellaneous

CT-10

1st Floor Halls, Lobby, Offices, Ping Pong Room, Laundry Room, Recycle Room, and Hallways on 2-8 Floors Floor(s): 1-8

No

Green Sheet Vinyl Flooring

Miscellaneous

SV-11

1st Floor Laundry Room and Bathrooms and other possible areas of building Floor(s): 1

No

Blue Carpet with Carpet Adhesive Miscellaneous (Yellow)

CA-12

Ping Pong Room Floor(s): 1

No

Multiple Purple Shaded Carpet with Carpet Adhesive (Yellow)

Miscellaneous

CA-13

Front of Laundry Room Floor(s): 1

No

Purple with Pink Spots Carpet with Carpet Adhesive (Yellow)

Miscellaneous

CA-14

Lobby Floor(s): 1

No

Purple/Pink with Blue Spots with Carpet Adhesive (Yellow)

Miscellaneous

CA-15

Lobby Floor(s): 1

No

Miscellaneous

TG-16

1st Floor West Restroom Floor(s): 1

No

Ceramic Tile Underlayment for 1” Miscellaneous Ceramic Tile

CU-17

1st Floor West Restroom Floor(s): 1

No

Grey Sheet Vinyl Flooring

Miscellaneous

SV-18

Unit 404 Bathroom and other possible areas of building Floor(s): 4

No

White Sink Undercoating

Miscellaneous

SK-19

Unit 201 Kitchen and other possible areas of building Floor(s): 2

No

Large Knock Down Wall Texturing Surfacing Compound

WT-20

Storage and Trash Rooms Floor(s): 1-8

No

Mauve Carpet with Carpet Adhesive (Yellow)

Miscellaneous

CA-21

Elevator Lobbys Floor(s): 2-8

No

Grey-Red Carpet with Carpet Adhesive (Yellow)

Miscellaneous

CA-22

8th Floor at East and West Ends Floor(s): 8

No

Tile Grout for 1” Ceramic Tile

Material Location(s)

Asbestos Present?

Section 3 Summary of Findings for Suspect Materials Page 2 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

November 9, 2009

Suspect Material

Category

HM Number

Red Brick Patterned Floor Tile And Adhesive (Yellow)

Miscellaneous

FA-23

Trash Rooms Floor(s): 2-8

No

Grey/Red Carpet with Green Trim Miscellaneous and Carpet Adhesive (Yellow)

CA-24

7th Floor at East and West Ends Floor(s): 7

No

Grey/Red Carpet with Blue Trim and Carpet Adhesive (Yellow)

Miscellaneous

CA-25

4th and 6th Floor at East and West Ends Floor(s): 4,6

No

Grey/Red Carpet with Red Trim and Carpet Adhesive (Yellow)

Miscellaneous

CA-26

5th Floor at West and East Ends Floor(s): 5

No

Grey/Red Carpet with Orange Trim Miscellaneous and Carpet Adhesive (Yellow)

CA-27

3rd Floor at East and West Ends Floor(s): 3

No

Grey/Red Carpet with Purple Trim Miscellaneous and Carpet Adhesive (Yellow)

CA-28

2nd Floor at East and West Ends Floor(s): 2

No

Surfacing Material ES-29

Unit Balconies, 1st Floor Front and Rear Entrances, and Penthouse Roof Floor(s): 1-8, Roof

No

Miscellaneous

RT-30

Roof Floor(s): Roof

No

Roof Patching Compound

Miscellaneous

RP-31

Vents and Penetrations Floor(s): Roof

No

Tile Grout for Red Tile

Miscellaneous

TG-32

Commerical Kitchen on 1st Floor Floor(s): 1

Yes (assumed)

Miscellaneous

CU-33

Commerical Kitchen on 1st Floor Floor(s): 1

Yes (assumed)

Exterior Stucco

Gravel and Roofing Tar

Ceramic Tile Underlayment for Red Tile

Material Location(s)

Asbestos Present?

Section 3 Summary of Findings for Suspect Materials Page 3 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Client Information

Southwest Tower Apartment (Site ID: Alice) 1501 Alice Street Oakland, CA 94612

Christian Church Homes 1501 Alice Street Oakland, CA 94612

Survey Performed By

Inspector

Inspection Date

Job Number

ACC Environmental Consultants, Inc.

Matt Chin

November 9, 2009

1299-005.00

Material Description

Material Number

Asbestos Present?

Orange Peel Wall Texturing Compound

WT-1

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Miscellaneous

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

Walls in Units and Hallways Floor(s): 1-8 Sample ID(s)

Sample Location(s)

Floor

Analyzed

WT-1-1

Unit 504 Bedroom Behind Bathroom Door

5

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-2

Unit 707 Entry Closet

7

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-3

Unit 704 Bedroom

7

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-4

Kitchen Pantry

1

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-5

Laundry Room

1

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-6

Mail Room Door

1

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-7

Office

1

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-8

Unit 801 Bedroom

8

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-9

Unit 818 Bedroom

8

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-10

Unit 617 Living Room

6

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-11

Unit 613 Bedroom

6

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-12

Unit 516 Bedroom

5

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-13

Unit 417 Bedroom

4

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-14

Unit 404 Bedroom

4

Yes

Negative

WT-1-15

Unit 305 Bedroom

3

Yes

Negative

1) Texture NONE DETECTED 2) Paint NONE DETECTED 3) Section 4 Page 1 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621 1) Texture NONE DETECTED

Overall Result

Layer(s) Reported by Lab

Results by Layer

WT-1-12

Unit 516 Bedroom

5

Yes

Negative

Section 4 Material Information Tables WT-1-13

Unit 417 Bedroom

Site Information

4

Southwest Tower Apartment (Site ID: Alice) WT-1-14 Unit 404 Bedroom

4

WT-1-15

Unit 305 Bedroom

WT-1-16

Yes

1) Texture 2) Paint 3)

1) Texture Negative Survey Performed By 2) Paint 3) ACC Environmental Consultants,

NONE DETECTED NONE DETECTED NONE DETECTED NONE DETECTED Inspection Date

Inc.

November 9, 2009

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

3

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

Unit 306 Bedroom

3

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-17

Unit 201 Bedroom

2

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-18

Unit 203 Bedroom

2

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-19

Unit 109 Entry

1

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-20

Unit 108 Entry

1

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-1-21

7th Floor Hallway

7

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

Section 4 Page 2 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

Material Description

Acoustical Ceiling Material

November 9, 2009

Material Number

Asbestos Present?

SA-2

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Surfacing

Friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

Ceilings in Units and Social Hall Floor(s): 1-8 Sample ID(s)

Sample Location(s)

Floor

Analyzed

SA-2-1

Unit 504 Living Room

5

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-2

Unit 707 Bedroom

7

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-3

Unit 704 Living Room

7

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-4

Social Hall North West Corner 1

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-5

Social Hall Center

1

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-6

Social Hall South East Corner 1

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-7

Social Hall North East Corner 1

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-8

Unit 801 Living Room

8

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-9

Unit 818 Living Room

8

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-10

Unit 617 Living Room

6

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-11

Unit 613 Bedroom

6

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-12

Unit 516 Living Room

5

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-13

Unit 417 Living Room

4

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-14

Unit 404 Living Room

4

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-15

Unit 305 Living Room

3

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-16

Unit 306 Bedroom

3

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED Section 4 Page 3 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621 3)

Overall Result

Layer(s) Reported by Lab

Results by Layer

3)

SA-2-14

Unit 404 Living Room

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

4

Yes

Unit 305 Living Room

3

Yes

SA-2-16

Unit 306 Bedroom

3

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-17

Unit 201 Living Room

2

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-18

Unit 203 Bedroom

2

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-19

Unit 109 Living Room

1

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

SA-2-20

Unit 109 Living Room

1

Yes

Negative

1) Acoustical Ceiling Material NONE DETECTED 2) Paint NONE DETECTED 3)

Section 4 Material Information Tables Site Information SA-2-15

Southwest Tower Apartment (Site ID: Alice)

Survey Performed By Inspection Date 1) Acoustical Ceiling Material NONE DETECTED Negative 2) Paint Consultants, Inc. NONE November DETECTED 9, 2009 ACC Environmental 3)

Section 4 Page 4 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

Material Description

Drywall And Joint Compound

November 9, 2009

Material Number

Asbestos Present?

JC-3

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Miscellaneous

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

Wall throughout Building and Ceilings in Kitchen and Bathrooms on 1st Floor and other possible areas of building. Floor(s): 1-8 Sample ID(s)

Sample Location(s)

Floor

Analyzed

Overall Result

Layer(s) Reported by Lab

JC-3-1

Unit 504 Bedroom

5

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

Results by Layer

JC-3-2

Unit 707 Living Room

7

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-3

Lobby

1

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-4

Kitchen

1

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-5

Handicap Restroom

1

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-6

Recycle Room

1

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-7

Office

1

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-8

Unit 801 Bedroom

8

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-9

Unit 818 Bedroom

8

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-10

Unit 617 Living Room

6

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-11

Unit 613 Bedroom

6

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-12

Unit 516 Bedroom

5

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-13

Unit 417 Bedroom

4

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-14

Unit 414 Bathroom

4

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-15

Unit 305 Bedroom

3

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-16

Unit 306 Bedroom

3

Yes

Negative

1) Drywall NONE DETECTED 2) Joint Compound NONE DETECTED Section 4 Page 5 Licensed to: ACC Environmental Inc., Oakland, CA, 94621 3) Paint NONEConsultants, DETECTED

JC-3-14

Unit 414 Bathroom

4

Yes

3

Yes

Section 4 Material Information Tables Site Information JC-3-15

Unit 305 Bedroom

Southwest Tower Apartment (Site ID: Alice)

Negative

3) Paint

NONE DETECTED

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

Survey Performed By 1) Drywall Negative 2) Joint Compound ACC Environmental Consultants, 3) Paint

Inspection Date NONE DETECTED

DETECTED 9, 2009 Inc.NONE November NONE DETECTED

JC-3-16

Unit 306 Bedroom

3

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-17

Unit 201 Bathroom

2

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-18

Unit 203 Bedroom

2

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-19

Unit 109 Entry

1

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-20

Unit 108 Entry

1

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

JC-3-21

4th Floor Storage

4

Yes

Negative

1) Drywall 2) Joint Compound 3) Paint

NONE DETECTED NONE DETECTED NONE DETECTED

Material Description

Material Number

Asbestos Present?

12”x12” Beige Floor Tile And Adhesive (Yellow)

FA-4

Yes

Material Category

Friable Classification

EPA Category

Total Quantity

Unit of Measure

Flooring

Non-friable

Category I

600

Square Feet

General Condition

Overall Material Assessment

Recommended Response

Good

Not Assessed under AHERA

Abate Prior To Disturbance

General Material Comments

Material Location(s)

Floors in Kitchens and Bathrooms of Units 108, 109, 201, 203, 305, 404, 417, 504, 516, 613 and other possible units not inspected. Floor(s): 1-6 Sample ID(s)

Sample Location(s)

FA-4-1

Unit 504 Kitchen

Floor

5

FA-4-2

Unit 613 Bathroom

FA-4-3

Unit 203 Kitchen

Analyzed

Overall Result

Layer(s) Reported by Lab

Results by Layer

Yes

2%

1) Tile 2) Adhesive 3)

2 % Chrysotile NONE DETECTED

6

No

Not Analyzed

1) Tile 2) Adhesive 3)

NOT ANALYZED (PRIOR POSITIVE) NOT ANALYZED (PRIOR POSITIVE)

2

No

Not Analyzed

1) Tile 2) Adhesive 3)

NOT ANALYZED (PRIOR POSITIVE) NOT ANALYZED (PRIOR POSITIVE)

Section 4 Page 6 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

November 9, 2009

Material Description

Material Number

Asbestos Present?

Brown Baseboard and Baseboard Adhesive (Brown)

BA-5

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Flooring

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Linear Feet

General Material Comments

Material Location(s)

Walls of 1st Floor and Units: 108, 109, 201, 203, 306, 404, 417, 504, 516, 613, 617, 704, 705, 707, 801, 818 and other possible units not inspected. Floor(s): 1-8 Sample ID(s)

Sample Location(s)

Floor

Analyzed

BA-5-1

Unit 504 Entry

5

Yes

Negative

1) Baseboard 2) Baseboard Adhesive 3)

NONE DETECTED NONE DETECTED

BA-5-2

Unit 707 Living Room

7

Yes

Negative

1) Baseboard 2) Baseboard Adhesive 3)

NONE DETECTED NONE DETECTED

Overall Result

Layer(s) Reported by Lab

Results by Layer

Material Description

Material Number

Asbestos Present?

2’x2’ Pinholed Ceiling Tile

CT-6

No

Material Category

Friable Classification

EPA Category

Total Quantity

Unit of Measure

Ceilings

Friable

N/A

1,024

Square Feet

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

General Material Comments

Material Location(s)

Kitchen Ceilings in Units: 108, 109, 201, 203, 306, 404, 417, 504, 516, 613, 617, 704, 705, 707, 801, 818 and other possible units not inspected. Floor(s): 1-8 Sample ID(s)

Sample Location(s)

Floor

Analyzed

Overall Result

Layer(s) Reported by Lab

Results by Layer

CT-6-1

Unit 504 Kitchen

5

Yes

Negative

1) Ceiling Tile 2) Paint 3)

NONE DETECTED NONE DETECTED

CT-6-2

Unit 704 Kitchen

7

Yes

Negative

1) Ceiling Tile 2) Paint 3)

NONE DETECTED NONE DETECTED

CT-6-3

Unit 617 Kitchen

6

Yes

Negative

1) Ceiling Tile 2) Paint 3)

NONE DETECTED NONE DETECTED

Section 4 Page 7 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

November 9, 2009

Material Description

Material Number

Asbestos Present?

Beige Sheet Vinyl Flooring

SV-7

No

Material Category

Friable Classification

EPA Category

Total Quantity

Unit of Measure

Flooring

Non-friable

N/A

300

Square Feet

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

General Material Comments

Unit 818 has two layers of inseperable sheet vinyl Material Location(s)

Kitchen and Bathroom Floors of Units: 617, 704, 707, 801, 818 and other possible units not inspected. Floor(s): 6-8 Sample ID(s)

Sample Location(s)

Floor

Analyzed

SV-7-1

Unit 707 Kitchen

7

Yes

Negative

1) Sheet Vinyl Flooring 2) Fibrous Backing 3) Mastic

NONE DETECTED NONE DETECTED NONE DETECTED

SV-7-2

Unit 818 Bathroom

8

Yes

Negative

1) Sheet Vinyl Flooring 2) Fibrous Backing 3) Mastic

NONE DETECTED NONE DETECTED NONE DETECTED

Overall Result

Layer(s) Reported by Lab

Results by Layer

Material Description

Material Number

Asbestos Present?

12”x12” Red/Orange Streaked Floor Tile And Adhesive (Black)

FA-8

Yes

Material Category

Friable Classification

EPA Category

Total Quantity

Unit of Measure

Flooring

Non-friable

Category I

1,300

Square Feet

General Condition

Overall Material Assessment

Recommended Response

Good

Not Assessed under AHERA

Abate Prior To Disturbance

General Material Comments

In addition, any other black floor tile mastic observed throughout the building should be assumed as asbestos containing. Material Location(s)

Social Hall and Kitchen Pantry. Floor(s): 1 Sample ID(s)

FA-8-1

Sample Location(s)

Floor

Social Hall

1

Analyzed

Yes

Overall Result

2%

Layer(s) Reported by Lab

Results by Layer

1) Tile 2) Adhesive 3)

NONE DETECTED 2 % Chrysotile

Material Description

Material Number

Asbestos Present?

Red Mosaic Sheet Vinyl Flooring

SV-9

Yes

Material Category

Friable Classification

EPA Category

Total Quantity

Unit of Measure

Flooring

Non-friable

Category I

250

Square Feet

General Condition

Overall Material Assessment

Recommended Response

Good

Not Assessed under AHERA

Abate Prior To Disturbance

General Material Comments

Material Location(s)

Rear Entry near Kitchen and other possible areas of building Floor(s): 1 Sample ID(s)

Sample Location(s)

Floor

Analyzed

SV-9-1

Rear Entry Near Kitchen

1

Yes

Overall Result

70%

Layer(s) Reported by Lab 1) Sheet Vinyl Flooring 2) Fibrous Backing 3) Mastic

Results by Layer

NONE DETECTED 70 % Chrysotile NONE DETECTED

Section 4 Page 8 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

November 9, 2009

Material Description

Material Number

Asbestos Present?

2’x4’ Fissured Ceiling Tile

CT-10

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Ceilings

Friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

1st Floor Halls, Lobby, Offices, Ping Pong Room, Laundry Room, Recycle Room, and Hallways on 2-8 Floors Floor(s): 1-8 Sample ID(s)

Sample Location(s)

Floor

Analyzed

CT-10-1

Rear Entry - Kitchen

1

Yes

Negative

1) Ceiling Tile 2) Paint 3)

NONE DETECTED NONE DETECTED

CT-10-2

Ping Pong Room

1

Yes

Negative

1) Ceiling Tile 2) Paint 3)

NONE DETECTED NONE DETECTED

CT-10-3

Lobby Hallway

1

Yes

Negative

1) Ceiling Tile 2) Paint 3)

NONE DETECTED NONE DETECTED

CT-10-4

8th Floor Hallway

8

Yes

Negative

1) Ceiling Tile 2) Paint 3)

NONE DETECTED NONE DETECTED

CT-10-5

6th Floor Hallway

6

Yes

Negative

1) Ceiling Tile 2) Paint 3)

NONE DETECTED NONE DETECTED

CT-10-6

4th Floor Hallway

4

Yes

Negative

1) Ceiling Tile 2) Paint 3)

NONE DETECTED NONE DETECTED

CT-10-7

2nd Floor Hallway

2

Yes

Negative

1) Ceiling Tile 2) Paint 3)

NONE DETECTED NONE DETECTED

Overall Result

Layer(s) Reported by Lab

Results by Layer

Material Description

Material Number

Asbestos Present?

Green Sheet Vinyl Flooring

SV-11

No

Material Category

Friable Classification

EPA Category

Total Quantity

Unit of Measure

Flooring

Non-friable

N/A

800

Square Feet

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

General Material Comments

Material Location(s)

1st Floor Laundry Room and Bathrooms and other possible areas of building Floor(s): 1 Sample ID(s)

Sample Location(s)

Floor

Analyzed

SV-11-1

Laundry Room

1

Yes

Overall Result

Negative

Layer(s) Reported by Lab 1) Sheet Vinyl Flooring 2) Fibrous Backing 3) Mastic

Results by Layer

NONE DETECTED NONE DETECTED NONE DETECTED

Section 4 Page 9 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

November 9, 2009

Material Description

Material Number

Asbestos Present?

Blue Carpet with Carpet Adhesive (Yellow)

CA-12

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Flooring

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

Ping Pong Room Floor(s): 1 Sample ID(s)

Sample Location(s)

Floor

Analyzed

CA-12-1

Ping Pong Room

1

Yes

Overall Result

Layer(s) Reported by Lab

Negative

1) Carpet Adhesive 2) 3)

Results by Layer

NONE DETECTED

Material Description

Material Number

Asbestos Present?

Multiple Purple Shaded Carpet with Carpet Adhesive (Yellow)

CA-13

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Flooring

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

Front of Laundry Room Floor(s): 1 Sample ID(s)

Sample Location(s)

CA-13-1

Front Of Laundry Room

Floor

1

Analyzed

Yes

Overall Result

Layer(s) Reported by Lab

Negative

1) Carpet Adhesive 2) 3)

Results by Layer

NONE DETECTED

Material Description

Material Number

Asbestos Present?

Purple with Pink Spots Carpet with Carpet Adhesive (Yellow)

CA-14

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Flooring

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

Lobby Floor(s): 1 Sample ID(s)

CA-14-1

Sample Location(s)

Lobby

Floor

1

Analyzed

Yes

Overall Result

Layer(s) Reported by Lab

Negative

1) Carpet Adhesive 2) 3)

Results by Layer

NONE DETECTED

Section 4 Page 10 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

November 9, 2009

Material Description

Material Number

Asbestos Present?

Purple/Pink with Blue Spots with Carpet Adhesive (Yellow)

CA-15

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Flooring

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

Lobby Floor(s): 1 Sample ID(s)

Sample Location(s)

Floor

Analyzed

CA-15-1

Lobby

1

Yes

Overall Result

Layer(s) Reported by Lab

Negative

1) Carpet Adhesive 2) 3)

Material Description

Tile Grout for 1” Ceramic Tile

Results by Layer

NONE DETECTED

Material Number

Asbestos Present?

TG-16

No

Material Category

Friable Classification

EPA Category

Total Quantity

Unit of Measure

Flooring/Walls

Non-friable

N/A

100

Square Feet

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

General Material Comments

Material Location(s)

1st Floor West Restroom Floor(s): 1 Sample ID(s)

Sample Location(s)

TG-16-1

Restroom West

Floor

1

Analyzed

Yes

Overall Result

Negative

Layer(s) Reported by Lab

Results by Layer

1) Tile Grout 2) 3)

Material Description

Ceramic Tile Underlayment for 1” Ceramic Tile

NONE DETECTED

Material Number

Asbestos Present?

CU-17

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Flooring/Walls

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

1st Floor West Restroom Floor(s): 1 Sample ID(s)

CU-17-1

Sample Location(s)

Restroom West

Floor

1

Analyzed

Yes

Overall Result

Negative

Layer(s) Reported by Lab

Results by Layer

1) Ceramic Tile Underlayment NONE DETECTED 2) 3)

Section 4 Page 11 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

November 9, 2009

Material Description

Material Number

Asbestos Present?

Grey Sheet Vinyl Flooring

SV-18

No

Material Category

Friable Classification

EPA Category

Total Quantity

Unit of Measure

Flooring

Non-friable

N/A

30

Square Feet

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

General Material Comments

Material Location(s)

Unit 404 Bathroom and other possible areas of building Floor(s): 4 Sample ID(s)

Sample Location(s)

Floor

Analyzed

SV-18-1

Unit 404 Bathroom

4

Yes

Overall Result

Negative

Layer(s) Reported by Lab

Results by Layer

1) Sheet Vinyl Flooring 2) Mastic 3)

NONE DETECTED NONE DETECTED

Material Description

Material Number

Asbestos Present?

White Sink Undercoating

SK-19

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Miscellaneous

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Each

General Material Comments

Material Location(s)

Unit 201 Kitchen and other possible areas of building Floor(s): 2 Sample ID(s)

Sample Location(s)

SK-19-1

Unit 201 Kitchen

Floor

2

Analyzed

Yes

Overall Result

Negative

Layer(s) Reported by Lab 1) Sink Undercoating 2) 3)

Results by Layer

NONE DETECTED

Section 4 Page 12 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

November 9, 2009

Material Description

Material Number

Asbestos Present?

Large Knock Down Wall Texturing Compound

WT-20

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Miscellaneous

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

Storage and Trash Rooms Floor(s): 1-8 Sample ID(s)

Sample Location(s)

Floor

Analyzed

WT-20-1

8th Floor Storage Room

8

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-20-2

7th Floor Trash Room

7

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-20-3

6th Floor Storage Room

6

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-20-4

5th Floor Trash Room

5

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-20-5

4th Floor Storage Room

4

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-20-6

3rd Floor Trash Room

3

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

WT-20-7

2nd Floor Storage Room

2

Yes

Negative

1) Texture 2) Paint 3)

NONE DETECTED NONE DETECTED

Overall Result

Layer(s) Reported by Lab

Results by Layer

Material Description

Material Number

Asbestos Present?

Mauve Carpet with Carpet Adhesive (Yellow)

CA-21

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Flooring

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

Elevator Lobbys Floor(s): 2-8 Sample ID(s)

Sample Location(s)

Floor

Analyzed

CA-21-1

8th Floor Elevator Lobby

8

Yes

Overall Result

Layer(s) Reported by Lab

Negative

1) Carpet Adhesive 2) 3)

Results by Layer

NONE DETECTED

Section 4 Page 13 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

November 9, 2009

Material Description

Material Number

Asbestos Present?

Grey-Red Carpet with Carpet Adhesive (Yellow)

CA-22

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Flooring

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

8th Floor at East and West Ends Floor(s): 8 Sample ID(s)

Sample Location(s)

Floor

Analyzed

CA-22-1

8th East End

8

Yes

Overall Result

Layer(s) Reported by Lab

Negative

1) Carpet Adhesive 2) 3)

Results by Layer

NONE DETECTED

Material Description

Material Number

Asbestos Present?

Red Brick Patterned Floor Tile And Adhesive (Yellow)

FA-23

No

Material Category

Friable Classification

EPA Category

Total Quantity

Unit of Measure

Flooring

Non-friable

N/A

175

Square Feet

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

General Material Comments

Material Location(s)

Trash Rooms Floor(s): 2-8 Sample ID(s)

Sample Location(s)

FA-23-1

8th Floor Trash Room

Floor

8

FA-23-2

5th Floor Trash Room

FA-23-3

3rd Floor Trash Room

Analyzed

Overall Result

Layer(s) Reported by Lab

Results by Layer

Yes

Negative

1) Tile 2) Adhesive 3)

NONE DETECTED NONE DETECTED

5

Yes

Negative

1) Tile 2) Adhesive 3)

NONE DETECTED NONE DETECTED

3

Yes

Negative

1) Tile 2) Adhesive 3)

NONE DETECTED NONE DETECTED

Section 4 Page 14 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

November 9, 2009

Material Description

Material Number

Asbestos Present?

Grey/Red Carpet with Green Trim and Carpet Adhesive (Yellow)

CA-24

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Flooring

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

7th Floor at East and West Ends Floor(s): 7 Sample ID(s)

Sample Location(s)

Floor

Analyzed

CA-24-1

7th Floor West End

7

Yes

Overall Result

Layer(s) Reported by Lab

Negative

1) Carpet Adhesive 2) 3)

Results by Layer

NONE DETECTED

Material Description

Material Number

Asbestos Present?

Grey/Red Carpet with Blue Trim and Carpet Adhesive (Yellow)

CA-25

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Flooring

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

4th and 6th Floor at East and West Ends Floor(s): 4,6 Sample ID(s)

Sample Location(s)

CA-25-1

6th Floor East End

Floor

6

Analyzed

Yes

Overall Result

Layer(s) Reported by Lab

Negative

1) Carpet Adhesive 2) 3)

Results by Layer

NONE DETECTED

Material Description

Material Number

Asbestos Present?

Grey/Red Carpet with Red Trim and Carpet Adhesive (Yellow)

CA-26

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Flooring

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

5th Floor at West and East Ends Floor(s): 5 Sample ID(s)

CA-26-1

Sample Location(s)

5th Floor East End

Floor

5

Analyzed

Yes

Overall Result

Layer(s) Reported by Lab

Negative

1) Carpet Adhesive 2) 3)

Results by Layer

NONE DETECTED

Section 4 Page 15 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

November 9, 2009

Material Description

Material Number

Asbestos Present?

Grey/Red Carpet with Orange Trim and Carpet Adhesive (Yellow)

CA-27

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Flooring

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

3rd Floor at East and West Ends Floor(s): 3 Sample ID(s)

Sample Location(s)

Floor

Analyzed

CA-27-1

3rd Floor West End

3

Yes

Overall Result

Layer(s) Reported by Lab

Negative

1) Carpet Adhesive 2) 3)

Results by Layer

NONE DETECTED

Material Description

Material Number

Asbestos Present?

Grey/Red Carpet with Purple Trim and Carpet Adhesive (Yellow)

CA-28

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Flooring

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

2nd Floor at East and West Ends Floor(s): 2 Sample ID(s)

Sample Location(s)

CA-28-1

2nd Floor East End

Floor

2

Analyzed

Yes

Overall Result

Layer(s) Reported by Lab

Negative

1) Carpet Adhesive 2) 3)

Results by Layer

NONE DETECTED

Section 4 Page 16 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

Material Description

Exterior Stucco

November 9, 2009

Material Number

Asbestos Present?

ES-29

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Surfacing

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

Unit Balconies, 1st Floor Front and Rear Entrances, and Penthouse Roof Floor(s): 1-8, Roof Sample ID(s)

Sample Location(s)

Floor

Analyzed

ES-29-1

8th Floor West Balcony

8

Yes

Negative

1) Cementitious Material 2) Paint 3)

NONE DETECTED NONE DETECTED

ES-29-2

8th Floor East Balcony

8

Yes

Negative

1) Cementitious Material 2) Paint 3)

NONE DETECTED NONE DETECTED

ES-29-3

Roof Stairs South

Roof

Yes

Negative

1) Cementitious Material 2) Paint 3)

NONE DETECTED NONE DETECTED

ES-29-4

Roof Stairs North

Roof

Yes

Negative

1) Cementitious Material 2) Paint 3)

NONE DETECTED NONE DETECTED

ES-29-5

1st Floor South East

1

Yes

Negative

1) Cementitious Material 2) Paint 3)

NONE DETECTED NONE DETECTED

ES-29-6

1st Floor South West

1

Yes

Negative

1) Cementitious Material 2) Paint 3)

NONE DETECTED NONE DETECTED

ES-29-7

1st Floor East

1

Yes

Negative

1) Cementitious Material 2) Paint 3)

NONE DETECTED NONE DETECTED

Overall Result

Layer(s) Reported by Lab

Results by Layer

Section 4 Page 17 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

November 9, 2009

Material Description

Material Number

Asbestos Present?

Gravel and Roofing Tar

RT-30

No

Total Quantity

Unit of Measure

Material Category

Friable Classification

EPA Category

Roofing

Non-friable

N/A

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

Square Feet

General Material Comments

Material Location(s)

Roof Floor(s): Roof Sample ID(s)

Sample Location(s)

Floor

Analyzed

RT-30-1

North

Roof

Yes

Negative

1) Tar 2) Felt 3)

NONE DETECTED NONE DETECTED

RT-30-2

East

Roof

Yes

Negative

1) Tar 2) Felt 3)

NONE DETECTED NONE DETECTED

RT-30-3

West

Roof

Yes

Negative

1) Tar 2) Felt 3)

NONE DETECTED NONE DETECTED

Overall Result

Layer(s) Reported by Lab

Material Description

Roof Patching Compound

Results by Layer

Material Number

Asbestos Present?

RP-31

No

Material Category

Friable Classification

EPA Category

Total Quantity

Unit of Measure

Roofing

Non-friable

N/A

100

Square Feet

General Condition

Overall Material Assessment

Recommended Response

Good

No Assessment, Non-asbestos

No Response Required

General Material Comments

Material Location(s)

Vents and Penetrations Floor(s): Roof Sample ID(s)

Sample Location(s)

Floor

Analyzed

RP-31-1

Drain Penetrations

Roof

Yes

Overall Result

Negative

Layer(s) Reported by Lab

Results by Layer

1) Roof Patching Compound 2) Paint 3)

Material Description

Tile Grout for Red Tile

NONE DETECTED NONE DETECTED

Material Number

Asbestos Present?

TG-32

Yes (assumed)

Material Category

Friable Classification

EPA Category

Total Quantity

Unit of Measure

Flooring/Walls

Non-friable

Category II

500

Square Feet

General Condition

Overall Material Assessment

Recommended Response

Good

Not Assessed under AHERA

Sample Prior To Disturbance

General Material Comments

Material Not Sampled. Visible Damage if Sampled. Material Location(s)

Commerical Kitchen on 1st Floor Floor(s): 1 Sample ID(s)

Sample Location(s)

Floor

Analyzed

Overall Result

Layer(s) Reported by Lab

Results by Layer

Section 4 Page 18 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 4 Material Information Tables Site Information

Survey Performed By

Southwest Tower Apartment (Site ID: Alice)

ACC Environmental Consultants, Inc.

Inspection Date

Material Description

Ceramic Tile Underlayment for Red Tile

November 9, 2009

Material Number

Asbestos Present?

CU-33

Yes (assumed)

Material Category

Friable Classification

EPA Category

Total Quantity

Unit of Measure

Flooring/Walls

Non-friable

Category II

500

Square Feet

General Condition

Overall Material Assessment

Recommended Response

Good

Not Assessed under AHERA

Sample Prior To Disturbance

General Material Comments

Material Not Sampled. Visible Damage if Sampled. Material Location(s)

Commerical Kitchen on 1st Floor Floor(s): 1 Sample ID(s)

Sample Location(s)

Floor

Analyzed

Overall Result

Layer(s) Reported by Lab

Results by Layer

Section 4 Page 19 Licensed to: ACC Environmental Consultants, Inc., Oakland, CA, 94621

Section 5 Removal Cost Estimate Summary These estimates are for budgeting purposes only and should not be used as a quote for removal of the materials. It is not our recommendation to remove these materials unless they are beyond repair, or planned demolition or renovation activities will disturb the materials. Estimates are based on recent pricing we have received from contractors performing similar work and may vary from actual prices obtained due to the actual scope of work, quantity of material removed, control measures specified and contractor work loads, etc.

Building HM

4

QTY. Units Removal Costs (low to high)

Southwest Tower Apartment

EPA Category

Category I

Suspect Material

12”x12” Beige Floor Tile And Adhesive (Yellow)

Material Location

Floors in Kitchens and Bathrooms of Units 108, 109, 201, 203, 305, 404, 417, 504, 516, 613 and other possible units not inspected.

600 Square Feet $1000

8

Category I

12”x12” Red/Orange Streaked Floor Tile Social Hall and Kitchen Pantry. And Adhesive (Black)

1,300 Square Feet $1950 to $3250

9

Category I

Red Mosaic Sheet Vinyl Flooring

Rear Entry near Kitchen and other possible areas of building

250 Square Feet $1500

32

Category II

Tile Grout for Red Tile

Commerical Kitchen on 1st Floor

500 Square Feet $1250

33

Category II

Ceramic Tile Underlayment for Red Tile Commerical Kitchen on 1st Floor

500 Square Feet $1000

Total Removal Costs:

Site ID: Southwest Tower Apartments Building ID: Alice Southwest Tower Apartment Asbestos Survey Report

$6,700

to

$8,750

Section 5 Page 1

Appendix A Definitions of Terms and Assessment Criteria

Definitions of Terms and Assessment Criteria

Definitions of Terms and Assessment Criteria This survey report organizes information on each suspect ACBM identified in tables located in Section 4. This section defines the terms used to describe materials listed in Section 4. Material description contains the description of the suspect homogeneous asbestos containing building material. Material Serial Number is used to reference the material for reinspections, etc.. Asbestos type and content describes the type of asbestos and its percentage in the material. Asbestos Results for positive materials are shown as a percentage. Samples having less than 1% asbestos are reported as containing “Trace” amounts of asbestos and samples with no detected asbestos are reported as “BLD” or below limit of detection. Sample number(s) identifies a particular material sample obtained from a specific sample location. Sample numbers are used primarily for laboratory identification. Sample Location identifies where the samples of this material were obtained. Material Category categorizes each material as surfacing, TSI or miscellaneous. Surfacing Materials - Asbestos containing materials that are sprayed-on, trowled-on or otherwise applied to surfaces, such as acoustical plaster on ceilings and fireproofing on structural members, or other materials on surfaces for acoustical, fireproofing, or other purposes. Thermal Systems Insulation (TSI) - Asbestos containing materials applied to pipes, fittings, boilers, breaching, tanks, ducts or other interior structural components to prevent heat loss or gain or water condensation. Miscellaneous Materials - Asbestos containing materials applied to or a part of building components that are not classified as surfacing materials or thermal systems insulation. Quantity & Units reports approximate total quantity per unit of measure for each material. Building(s) & Floor(s) specifies where a material is located. Material Location describes where the material is found throughout the building. Material Condition identifies the material as Friable, Non-friable or Jacketed (for thermal systems insulation only) if asbestos is present. Friable - An asbestos containing material that can be crumbled, pulverized or reduced to powder, when dry, by hand pressure, such as spray applied fireproofing on structural steel members, spray applied acoustical ceiling materials or damaged thermal systems insulation. Friable materials are of greatest concern due to their potential fiber release. Non-Friable - An asbestos containing material where the asbestos is bound tightly in a matrix or sealed by a protective layer. Non-friable materials can become friable by being rendered to a crumbled, pulverized or powdered state, when dry, by crushing, sanding, sawing, shot-blasting, severe weathering or by other mechanically induced means. Common examples of non-friable materials are adhesives, floor tiles, transite and roofing materials. Jacketed - An asbestos containing material applied to thermal systems insulation and “jacketed” with a protective outer layer such as canvas or metal to keep the material in good condition. Undamaged jacketed ACBM is considered non-friable. If the jacketing is damaged, the material is considered friable. Damage Category describes the type of damage, if any, to the material. The following damage categories are used: None, Physical, Air, and Water. Material Assessment identifies the condition of the material in relation to physical and water damage, delamination of the material from its substrate, the extent of the damage and the potential for damage from building conditions, such as, accessibility by building occupants, influence of vibration, etc. The six standard assessment categories ranked by hazard potential, with the first being the lowest hazard are as follows: 1) Potential for Damage, 2) Potential for Significant Damage, 3) Damaged, 4) Damaged with Potential for Damage, 5) Damaged with Potential for Significant Damage, and 6) Significantly Damaged. Only friable materials are assessed under AHERA regulations. Non-friable materials, unless damaged, are not assessed and can be assumed to be in good condition.

material from its substrate, the extent of the damage and the potential for damage from building conditions, such as, accessibility by building occupants, influence of vibration, etc. The six standard assessment categories ranked by hazard potential, with the first being the lowest hazard are as follows: 1) Potential for Damage, 2) Potential for Significant Damage, 3) Damaged, 4) Damaged with Potential for Damage, 5) Damaged with Potential for Significant Damage, and 6) Significantly Damaged. Only friable materials are assessed under AHERA regulations. Non-friable materials, unless damaged, are not assessed and can be assumed to be in good condition.

Damaged - The damage or deterioration of the material results in inadequate cohesion or adhesion with crumbling, blistering, water stains, marring or otherwise abraded over less than on-tenth (1/10) of the surface if the damage is evenly distributed or one-fourth (1/4) if the damage is localized. Significant Damage - The damage or deterioration of the material results in inadequate adhesion or cohesion and the damage is extensive and severe with one or more of the following characteristics: 1) Crumbling or blistering over at least one-tenth (1/10) of the surface if evenly distributed, one-fourth (1/4) if the damage is localized; 2) Areas of the material hanging from the surface, delaminated, or showing adhesive failure; 3) Water stains, gouges or marred. Recommended Response suggests the appropriate options for controlling or maintaining ACBM in a safe manner. There are four options used: Operations & Maintenance (O&M) - A program designed to “manage” asbestos in-place. As long as asbestos containing materials remain in a building, an O&M program should be instituted to alert maintenance personnel, custodial workers and outside vendors of the existence and location of these materials and to set a policy for the maintenance of these materials. The material is usually only required to be removed if it is significantly damaged, prior to demolition of the building or if it will be disturbed by renovation activities. Repair - The restoration of damaged or deteriorated asbestos containing building materials to an intact condition. Once the intact condition is established, the material should be included in an O&M program. The material is usually only required to be removed if it is significantly damaged, prior to demolition of the building or if it will be disturbed by renovation activities. Abate Due to Condition - This material is significantly damaged and is unsafe in its current condition. The access to the area should be restricted to personnel equipped with appropriate personal protection. This material should be properly removed by a licensed contractor using workers trained in the safe removal of asbestos. Abate Prior to Renovation - This material should be properly removed prior to planned renovation activities by a licensed contractor using workers trained in the safe removal of asbestos. This recommendation is usually made only on survey reports prepared prior to planned renovation activities. Comments & Damage Description contains any additional information and or specific details of material damage are noted here. EPA Category provides the appropriate material category as outlined in the NESHAPS regulation. The four options are friable, Category 1, Category 2, and needs determination. Friable - Materials containing greater than 1% asbestos are always considered Regulated Asbestos Containing Materials (RACM) that require removal prior to building renovation or demolition activities that impact the material. Category 1 - Materials that are bituminous non-friable and contain more than 1% asbestos that become RACM and require removal only when will be subject to grinding, cutting, sanding or abrading. Category 2 - Materials that are non-friable and contain more than 1% asbestos that will have a high probability of being crumbled, pulverized or reduced to a powder by the demolition or renovation activity. These material usually become RACM and will require removal. Needs Determination - Materials that the individual designing the abatement and demolition project needs to inspect and evaluate to determine the potential for the material to become RACM and/or evaluate the asbestos content for the composite and individual layers of the material. For sheet rock with mudding compounds only, the EPA allows using the composite sample result. If the composite result by Point Counting the sample is below 1% asbestos, the material is not RACM.

Appendix B Bulk Sampling Protocol and Analytical Methods

Bulk Sampling Protocol and Analytical Methods Bulk samples of suspect asbestos containing building materials were obtained using standard industrial hygiene techniques including wetting friable materials to minimize fiber release. When necessary, our personnel wore half-face air purifying respirators equipped with high efficiency particulate (HEPA) filters while obtaining samples. Our sampling strategy for suspect friable surfacing materials was based on the guidelines outlined in the EPA publication “Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials,” the procedures outlined in 40 CFR 763, Subpart E (AHERA). For non-friable suspect materials, AHERA requires the building inspector to determine the appropriate number of samples to obtain and analyze. Usually one to three samples of non-friable materials are collected For each homogeneous material identified by visual inspection as suspect material, random samples are obtained. A bulk sample is randomly selected from each homogeneous material for first-round testing. If the sample is positive, the remaining samples are not analyzed; if the sample is negative, the other samples are submitted for study. Every sample must be reported negative if the material is to be considered non-asbestos containing. The bulk samples were delivered to an independent laboratory that participates in the bulk sample proficiency analysis program conducted by the United States Environmental Protection Agency and is accredited by the National Voluntary Laboratory Program (NVLAP). The samples were analyzed using Polarized Light Microscopy (PLM) with dispersion staining to estimate the percent of asbestos composition by volume. Samples with no observable asbestiform minerals are designated as Non-Detect (ND). Samples in which asbestiform minerals are observed, but exist in concentrations of less than one percent (