Ballston Oak Townhomes - Arlingtonva

Report 2 Downloads 52 Views
Ballston Oak Townhomes Site Plan #436

CPHD SPRC #1 - July 23, 2015

Site & Location

2

GLUP/Zoning • “Low-Medium” Residential

• R15-30T

3

4

Applicable Plans and Policies • ACZO Section 5.8 (R15-30T, Townhouse Dwelling District) • GLUP “Low-Medium” Residential – 16-36 units per acre

• Ballston Sector Plan – North Ballston subarea

• R-B Streetscape Standards – “Type C” street 5

Ballston Sector Plan • Neighborhood Preservation and Residential Infill • Urban Design – Streetscape – Neighborhood Preservation • Minimize interruption of public sidewalks (24’ driveway maximum width) • Infill projects should include architectural details and site layouts compatible with existing house styles • Screen at-grade parking from adjacent residential 6 areas

Site Plan Proposal • 12 dwelling units in 4 buildings • Building heights range from 3-4 stories • 27 off-street parking spaces – 24 residential spaces – 3 visitor spaces

• N. Stuart Street to accommodate two travel lanes, one in each direction – Accomplished by widening curb-to-curb area and reducing amount of on-street parking 7

Site Development Potential Site Plan Area: 25,000 sq ft

“R15-30T” By-Right

DENSITY ALLOWED/TYPICAL USE

One-family dwellings: 5,000 sq ft/unit;

MAXIMUM DEVELOPMENT

One-family dwellings: 5 units

Other: min. 5,000 sq. ft. lot area

“R15-30T” Site Plan

Two-family dwellings: 4,350 sq. ft./unit; Semi-detached/townhouse dwellings: Up to 15 DU/Ac Townhouses, semi-detached, and one-family dwellings on sites at least 17,424 sq. ft.: Up to 1630 DU/Ac

Two-family dwellings: 5 units Semi-detached/townhouse dwellings: 8 units Townhouses, semi-detached, and onefamily dwellings on sites at least 17,424 sq. ft.: 9-17 units

8

Requested Modifications • Required Yards and Permitted Encroachments Yard

Requirement

Proposal

Front – building

25’

8’

Front – stoop

25’

4’

Side

17’

10’

Rear

25’

10’

– Visitor surface parking proposed in required rear yard – Proposed trellis height (10’) exceeds that allowed to encroach in required rear and side yards (8’)

• Lot Coverage – 69.7% proposed; 56% permitted

• Screening wall – 6’ proposed; 4’ permitted

9

N. Stuart St. – Existing Streetscape

4’ 6’ 7’

15’

Existing Conditions*

* Consistent with Ballston Sector Plan

10

N. Stuart St. – R-B Corridor Streetscape (Type C) 6’ 4’ 7’

15’

R-B Corridor Streetscape Standards (2003, rev. 2007)

11

N. Stuart St.- Proposed Streetscape

4.5’ 6’ 4’

26’

Proposed Site Plan*

* Consistent with R-B Corridor Streetscape Standards

12

Preliminary Issues • Site Design/Building Architecture – Project has significantly improved since the original proposal...

13

15

16

Preliminary Issues • Tree Canopy Question – Answered! • Staff has reviewed this with Urban Forestry and it appears to be compliant with Chesapeake Bay Ordinance

17

Questions?

18