Brian Trematore Plumbing & Heating, Inc.

Report 11 Downloads 198 Views
Brian Trematore Plumbing & Heating, Inc. 5 Daniel Road East Fairfield, NJ 07004

Phone: 973-227-8330 Fax: 973-227-7066

www.trematore.com New Jersey Master’s Plumbing License # 36BI00692200 New Jersey Plumbing Inspector HHS #008684 New Jersey Construction Official #008684 New Jersey Building Inspector #008684 New Jersey Plumbing Subcode Official #008684 New Jersey Home Improvement #13VH03849800 New Jersey Dept of Labor cert. #69465 Delaware Plumbing License # PL-0002146 Westchester County, NY Plumbing License # 957

Alabama Plumbing License # 00903 California Plumbing License #956501 Connecticut Plumbing License # PLM-0277678-P1 Maryland Plumbing / Gas Fitter License# 78655 Alabama Gas Fitter License # 00557 Pennsylvania Plumbing License #001284 Florida Plumbing License # CFC1425854 North Carolina Plumbing License # 28898 Virginia Plumbing License # 2710030164

Submittal Cover Sheet PROJECT NUMBER

PROJECT NAME

BRUNSWICK ESTATES Jersey City, N.J. General Contractor

Engineers

Mechanical Contractor

DiMarco Constructors

M/E Engineering

Brian Trematore Plumbing & Heating Inc.

Description of submittal Apartment Condensers & Air Coils TAB M08

Stamp:

SUBMITTAL DATA SHEET LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER – R-410A – 1 PHASE – 1.5 THRU 5 NOMINAL TONS MODELS: TC3B18 THRU 60 Brunswick Estates

JOB NAME:

LOCATION:

PURCHASER:

Jersey City, New Jersey

ORDER NO:

ENGINEER: SUBMITTED TO:

FOR:

REF:

APPROVAL:

CONSTRUCTION:

SUBMITTED BY:

DATE:

UNIT DESIGNATION:

SCHEDULE NO.

PRODUCT DATA

MODEL NO.

TC3B2421H

DIMENSIONS - INCHES

Cooling Performance

24 Total Capacity ________ MBH Outdoor Design Temp_________

C

°F

Electrical Data

60 1 208-230 Power Supply____/___/_____ Compressor Ampacity _______AMPs

12.3 Total Unit Ampacity ________AMPs

A

Power Input Req__________KW

12 Minimum Wire Size_________AWG Maximum Overcurrent Device †Fuses

†Circuit Breaker

Unit Weight

B

Unit Weight ________LBS 130

A0339-001

Dimensions (Inches)

Unit Model

®

Refrigerant Connection Service Valve Size

A

B

C

TC3B1821(S,H) TC3B2421(S,H) TC3B3021(S,H) TC3B3621(S,H) TC3B4221(S,H) TC3B4821S

23-1/2 26-3/4 30 33-1/4 26-3/4 30

24 24 24 24 29-1/4 29-1/4

24 24 24 24 29-1/4 29-1/4

TC3B6021S

36-1/4

29-1/4

29-1/4

Liquid

Vapor

3/4 3/8 7/8 7/8‡

‡ Adapter fitting must be field installed for the required 1-1/8” line set. All dimensions are in inches and are subject to change without notice. Overall height is from bottom of base pan to top of fan guard. Overall length and width include screw heads.

Johnson Controls Unitary Products

5146695-BSD-A-0715

FEATURES

WARRANTY SUMMARY*

• Small Footprint - Minimum footprint for easier handling, transportation, and installation. • Easier Installation- Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. Options are provided for indoor piston or TXV. The factory installed filter-drier and factory charge for a 15-Ft lineset means less time spent brazing and charging the system. The small base dimension and reduced unit clearances make for easier retrofits. • Accessible Information - QR code on unit provides quick access to technical documents and warranty information. • Durable Finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Titanium colored powdercoat paint further protects external panels. • Quality Coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system providing reliable performance and small unit size. • Rugged Coil Protection - Coils are protected from mechanical damage by a proven stamped steel coil guard design. • Protected Compressor - Compressors are protected internally by a high pressure relief valve and a temperature sensor, and externally by the system high pressure switch. The liquid line filter-drier is factory installed to protect the compressor against moisture and debris. • Reliable Operation - Ball bearing fan motors provide superior performance in extreme temperatures. • Environmentally Friendly - CFC-free R-410A refrigerant delivers environmentally friendly performance with zero ozone depletion. • Top Discharge - Warm air is blown up, away from the structure and any landscaping and allows compact location on multi-unit applications. • Low Operating Sound Levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides sound performance of 76 dBA or lower. Compatible accessories for further sound reduction are also available. • Better Service Access - Diagonal base valves with open access for low-loss fittings, single panel access to the electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for unit maintenance. • Agency Listed - Safety certified by CSA to UL 1995 / CSA 22.2. Performance certified to ANSI/AHRI Standard 210/240 in accordance with the Unitary Small Equipment certification program.

Standard 5-Years limited parts warranty. Standard 10-Years limited compressor warranty. Extended 10-Years limited parts warranty when product is registered online within 90 days of purchase for replacement or closing for new home construction. *Does not apply to R-22 models, 3-Phase models, or Internet sales. See Limited Warranty certificate in User's Information Manual for details.

TYPICAL CLEARANCES The minimum clearances for a typical installation are shown below. See the Technical Guide for alternate installations. • 10" Clearance Coil Area • 48" Overhead Clearance • 18" Minimum Service Panel Access • 24" Minimum Unit to Unit Distance

MATCHING AIR SIDE EQUIPMENT Model No.

†________________________

Submittal Form No.

†________________________

FIELD INSTALLED ACCESSORIES Off Cycle Time Delay (S1-2TD08700124) Standard Low Ambient Control (S1-2LA06700424) Advanced Low Ambient Control (6/$) Low Pressure Switch Kit (S1-2PS06700524) Compressor Start Assist (S1-2SA067_______________)* Compressor Crankcase Heater (S1-025_____________)* Support Feet (S1-HPRKIT-________)* Anchor Bracket Kit (S1-1HK0401) Indoor TXV Kit (S1-1TVM__________________)* Wall Mount Kit (S1-ACB-________)* Compressor Sound Blanket (S1-010076_____________)* * See price pages for accessory information.

Refer to Technical Guide for detailed specifications on the unit and its accessories. Verify the actual ratings for each specific matchup in the online AHRI directory at www.ahridirectory.org at the time of bid or sale. It is also recommended to print the rating certificate, if needed, at the time of bid or sale.

Subject to change without notice. Published in U.S.A. Copyright © 2015 by Johnson Controls, Inc. All rights reserved.

York Internation Corp. 5005 York Drive Norman, OK 73069

5146695-BSD-A-0715 Supersedes: Nothing

SUBMITTAL DATA SHEET FULL-CASED UPFLOW/DOWNFLOW ADD-ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: CF

Brunswick Estates

JOB NAME:

LOCATION:

PURCHASER:

Jersey City, New Jersey

ORDER NO:

ENGINEER: SUBMITTED TO:

FOR:

REF:

APPROVAL:

CONSTRUCTION:

SUBMITTED BY:

DATE:

UNIT DESIGNATION:

SCHEDULE NO.

PRODUCT DATA

MATCHED INDOOR UNIT †Model Number (#_______________________________)

Cooling Performance

†Submittal Part Number (#_________________________

24 Total Capacity*________________ MBH Sensible Capacity*_____________ MBH Temperature of Air Entering Indoor Coil _______°F (DB/WB

MATCHED OUTDOOR UNIT †Model Number (#_______________________________) †Submittal Part Number (#_________________________

Supply Air Blower Performance Total Supply Air______________________ CFM Total Resistance External To Unit _______ IWG Blower Speed Tap ____________________ RPM Motor Rating _________________________ HP

Unit Weight Total Operating Weight ________LBS 50 (Including field-installed accessories) * Shown in Outdoor Unit Technical Guide

CLEARANCES Front Rear Sides

MODEL NO.

24” 0” 0”

Recommended service clearance.

FEATURES RC2 - Rigid Case Construction interior endoskeleton for structural support, flush side, and locks in insulation. Powder-painted - G30 galvanized steel case provide a coated edge that resists corrosion and rust creep. MaxAlloyTM Coil - Long life aluminum coils built to deliver lasting performance, efficiency and reliability. Quality Construction - Structural components are made of Aluminum or G90 galvanized steel to prevent corrosion. Improved Insulation Design - Single piece with no external screws to reduce thermal transmission paths to prevent sweating. Foil faced insulation for ease of cleaning. Thermostatic Expansion Valve - Bolt-on TXV provides easy installation to convert the indoor coil to the required refrigerant that does not require brazing to replace or install. Some models are available with factory installed TXV. Case Depth - These models have 20.5” casing which provide ease of attic access and tight applications. Thermoset Drain Pan - Positive slope for drainage to reduce cause for potential mold or contaminants.

FIELD INSTALLED ACCESSORIES †Capacity †Filter Rack ISO 9001 Certified Quality Management System

(@____________Volts) _____________ MBH (#______________________________)

†Interconnecting Lines. . . . . Length_________________ Ft †Thermal Expansion Valve Kit (#_____________________) †UV Light Kit (#__________________________________)

Johnson Controls Unitary Products

5005745-USD-A-0815

DIMENSIONS - INCHES 19-1/8” (OPENING)

C (OPENING)

A

20-1/2”

B

21-1/2”

BOTTOM OPENING DIMENSIONS 19-1/8" D (OPENING) A0320-001

Dimensions - CF Upflow/Downflow Full Cased Coils Models

Height A

CF18AXA1 CF18BXA1 CF24AXA1 CF24BXA1 CF24CXA1 CF30AXA1 CF30BXA1 CF30CXA1 CF30DXA1 CF36AXA1 CF36BXA1 CF36CXA1 CF36DXA1 CF42BXA1 CF42CXA1 CF42DXA1 CF48CXA1 CF48DXA1 CF60CXA1 CF60DXA1 CF64DXA1

19-1/2 19 19-1/2 19 21 21-5/8 23 21 25 25-1/2 25-5/8 23 25 25 25 25 27 27 33 32-3/4 32-3/4

Dimensions 1 Width Opening Widths B C D 14-1/2 17-1/2 14-1/2 17-1/2 21 14-1/2 17-1/2 21 24/1/2 14-1/2 17-1/2 21 24-1/2 17-1/2 21 24-1/2 21 24-1/2 21 24-1/2 24-1/2

13-1/2 16-1/2 13-1/2 16-1/2 20 13-1/2 16-1/2 20 23-1/2 13-1/2 16-1/2 20 23-1/2 16-1/2 20 23-1/2 20 23-1/2 20 23-1/2 23-1/2

13-1/2 16-1/2 13-1/2 16-1/2 20 13-1/2 16-1/2 20 23-1/2 13-1/2 16-1/2 20 23-1/2 16-1/2 20 23-1/2 20 23-1/2 20 23-1/2 23-1/2

Refrigerant Connections 2,3,4 Line Size Liquid Vapor

3/4

3/8

7/8

1. All dimensions are in inches. 2. Refrigerant line sizes may require larger lines for extended line lengths. See Application Data part number 247077. 3. Adapter fitting must be field installed for other line set size. 4. See outdoor unit technical guide for proper line set size.

Subject to change without notice. Published in U.S.A. Copyright © 2015 by Johnson Controls, Inc. All rights reserved.

York International Corp. 5005 York Drive Norman, OK 73069

5005745-USD-A-0815 Supersedes: Nothing