2 of 14 Mastering Chief's CAD Tools

Report 1 Downloads 127 Views
2 of 14 Mastering Chief's CAD Tools NO. DESCRIPTION:

10'-0"

BY:

DATE:

Welcome To The Webinar 10'-8"

10'-0"

8"

21'-4"

12" x 12" CONCRETE BEAM WITH REE BAR. 4" x 3'5" LEDGE

BATH 4'-0"

6'-0" 11'-8"

5'-6"

9'-2"

9070

6'-0"

6'-11"

4'-1"

3068

3'-0"

2870

SHOWER

UTILITY 10'-4"

35'-10 3/4" 24'-0 3/4"

3'-0"

25'-2 1/2"

10'-7 1/2"

GARAGE

9'-4"

5"

8

Mfg. Engineered Truss System

9070

2" x 12" FRAMING W/ TREATED RIM JOISTS

12'-2 1/2"

9'-2"

12

24'-0 3/4"

25'-4"

R50 Blown Insulation

3'-0"

51'-8"

IWS to 24" inside Wall Line

25'-0"

2" x 12" FRAMING WITH TREATED RIM JOISTS

4'

11 1/4" 4 3/4"

3'-0"

0

3'-0"

16'-4" 50'-8"

3'-0"

12'-8"

8"

12'-8"

9'-4"

3'-0"

3'-0"

8" 6"

8'-8"

15'-8"

19'-10"

86"

2x6" Treated Sill w/ Sill Sealer Metal "J" Bolt

26 5/16"

952-236-4427

10'-6"

24"

3068

6061

12" Concrete walls 1-1/2" Foam Ins. 2x Furred Walls 24" o.c. 4 mil. poly VB 1/2" Sheetrock

4'-11 3/4"

Mastering Chief Architect X6 Session 2 of 14 by: Dan Baumann

12'-4"

9'-2"

4 3/4"

PROJECT DESCRIPTION:

18'-8"

Cap Trim TBD 1x10" Treated 4 Mil Poly VB

2" x 12" FRAMING W/ TREATED RIM JOISTS

13'-2"

LP Smartside siding 1/2" Ply. sheathing House Wrap 2x6" SPF Studs 16" o.c. R19 Batt Insul. 4 mil poly VB 1/2" Sheetrock

8'-2"

8'-6 1/2"

7'-3"

3'-0"

1'-6"

Roof Edge 5/4 x 4" Smart Trim 1x8" Smart Trim 2x8" Sub Fascia Smart Trim Soffit Vent

9'-2"

4 mil. Poly VB 5/8" Sheetrock

Welcome

6"

10'-11"

SHEET TITLE:

6'-1"

Timberline 30yr. Shingles 15# felt 1/2" OSB Sheathing

DATE: 7/10/2014 SCALE: No Scale:

Dan Baumann Your Presenter

Sally's 10th Birthday

© 2014 ChiefExperts.com All Rights Reserved. Prin ng for personal use is acceptable. Distribu on and Reproduc on for others is prohibited without wri en permission from ChiefExperts.com, Inc.

SHEET:

01-1

© 2014 ChiefExperts.com All Rights Reserved. Prin ng for personal use is acceptable. Distribu on and Reproduc on for others is prohibited without wri en permission from ChiefExperts.com, Inc.

BY: NO. DESCRIPTION: SHEET TITLE:

What's Included 952-236-4427

Mastering Chief Architect X6 Session 2 of 14 by: Dan Baumann

PROJECT DESCRIPTION:

1. Introduction to Chief Architect 2D CAD tools 2. Learn to think in terms of CAD -- X, Y, Z 3. Everything you draw is based on CAD polylines 4. Review of common CAD tools 5. Edit behaviors - how things act on the screen 6. Other tools 7. Group CAD items 8. CAD tools used regularly 9. Point & snap tools 10. CAD - Defaults 11. Drawing in a CAD Detail Window 12. Point to Point Snaps 13. Shaping CAD polyline boxes 14. Trim and Extend Tools 15. Working with Angles in CAD 16. Miscellaneous CAD functions 17. Q&A

DATE:

What We'll be Covering In This Webinar

DATE: 7/10/2014 SCALE: No Scale: SHEET:

01-2

Introduc on to Chief's CAD Tools NO. DESCRIPTION:

BY:

2. Drawing in Saved Camera Views

WEST ELEVATION

2 A-6

Open Saved Camera 2nd Floor Room Walls

CX145 (L)

Walls Above

Carpet

Walls Above

GAME AREA UNEXCAVATED

Ridge Vent

1 A-6

1-1/2" Blocking, Sheathing and Siding on end of Fnd.

(2) 11-7/8" LVL Flushed

12

3 A-6

W305515

W305515

FP

B3018

CX145 (R)

Carpet

Display Top UC REF REF.

Conc.

SB27 D/W

2068

1'-10 1/2"

6'

Inframe Bearing Point

B2718

9' 2430

Tile

3668

40'

8

4'-1"

Sump

Angled Wall at Bottom of Stairs

Inframe Bearing Point

LP Smartside Siding Tyvek or Equal House Wrap 1/2" Ply. sheathing 2x6" SPF Studs 16" o.c. R19 Batt Insul. 4 mil poly VB 1/2" Sheetrock

BEDROOM Carpet

2'-4"

4'-2"

13'-1 1/4"

6'-1 1/4"

4068

SHELTER Vinyl/Commercial

14 14

12

3'-6"

1'-6 1/2"

Infill frame to Top of Fnd. extend concrete slab

10'-6 3/4"

Roof Edge 5/4 x 4" Smart-trim 1x8" Smart-trim 2x8" Sub-fascia Smart-trim Soffit Vent

12 12

Gable Buildout 2x8" Framing 1/2" Sheathing Tyvek or Equal House Wrap 1/2" Smart Side Panel 1x3" Smartside Batton

Sound Insulate Under Stair

SD

Bookcase Door

14

CW145 (L)

BATH

CLOSET

6'-10 1/4"

Conc. Pad

SD

Toilet

Access Plug

14'-0 3/4"

3068

Carpet

20'-7 1/4"

2868

11'-2"

ELEV.

UP

Carpet

4'-1"

HALL

5'-3 3/4"

Carpet

3 A-1

(3)11-7/8" LVL's Dropped

W2736

2868

5'-6 1/2"

4068

4'-2" 1'-9"

11'-9" B3618

42x48" - 36" off Flr. Wrapped with sill 8" deep

EXCERCISE AREA

4838 Fixed Tempered

8"

4'-2"

Sport Floor

12'-1" B2718 W2736

Art Niche

NORTH ELEVATION

Tile

4'-6 1/2"

3068

4'-9"

SD

2x8" Framing 1/2" Sheathing Smart Side Panel 1x3" Smartside Batton 1x6 Smartside Corner Board 76 Series 8"o.c. Smartside Panel 1x6 Smartside Trim Boards

Tile

3DB2421

16'-9 1/2"

WSTE

BAR

Standard Tub (right) [60W]

23'-11 1/2"

SPORT COURT

12

5/4x8" Smart Side Frieze

CX145 (L) CX145 (S)

FAMILY ROOM

W351332

Furnace

UTILITY

17'-9 1/4"

6'-10 3/4"

2x6" Studs 16" oc 8 x 20" Ftg. Fiberglass Ins. 1/2" Sheetrock

12 14

Air

5'-10 1/2"

SOUTH ELEVATION

2x Furred Walls 24" oc 1-1/2" Foam Ins. 1/2" Sheetrock

WH

Stone Veneer Chimney

8

B3018

Rustic Fireplace 2 Panel

Radon Vent Elec Panel

2 A-1

Timberline Ultra Shingles (Per Mfg. Specs) 30# Felt 1/2" Plywood Sheathing

Ridge Vent

You Can Use the CAD Tools In all Views Except the 3D Cameras

CX145 (R)

Walls Above

4 A-6

Stone Veneer

SHEET TITLE:

4 A-1

Stone Veneer

Stone Veneer

Stone Veneer

Mastering Chief Architect X6 Session 2 of 14 by: Dan Baumann

1. Drawing on Floorplans

DATE:

Where Do You Use The 2D CAD Tools in Chief

2 A-6

UNEXCAVATED

2 A-6

4" Conc. Slab

1 A-6

4. Drawing on The Layout Pages

3. Drawing in CAD Detail Windows

PROJECT DESCRIPTION:

GAR

AG ER

EA

R EL

EV

AT ION

ENEXCAVATED

6 A-1

952-236-4427

Adding CAD Details Ridge Vent

Rename to Organize

Timberline 30yr. Shingles 15# felt 1/2" OSB Sheathing

12

14 14

12 8

Timberline 30yr. Shingles 15# felt 1/2" OSB Sheathing

Mfg. Engineered Truss System 12 12

8

8

IWS to 24" inside Wall Line

R 50 Blown Insulation

Mfg. Engineered Truss System

IWS to 24" inside Wall Line R50 Blown Insulation

Attic Trusses Skewed 30 degrees

Trayed Ceiling 11'-3"

(3) 7-1/4 LVL

3' 8' 8'-1 1/8" Notch Mfg. Floor Truss to Bear on Girder

LP Smartside siding 1/2" Ply. sheathing House Wrap 2x6" SPF Studs 16" o.c. R19 Batt Insul. 4 mil poly VB 1/2" Sheetrock

3/4" T&G Subfloor

6

Roof Edge 5/4 x 4" Smart Trim 1x8" Smart Trim 2x8" Sub Fascia Smart Trim Soffit Vent

10'

2'

12

Step Down Into Bonus Room

3'

17'-10 1/4" 8'-10 1/4"

16'-1 3/4"

4 mil. Poly VB 5/8" Sheetrock

(2) 11-7/8 LVL 3/4" T&G Subfloor

LP Smartside siding 1/2" Ply. sheathing House Wrap 2x6" SPF Studs 16" o.c. R19 Batt Insul. 4 mil poly VB 1/2" Sheetrock

12

Spray Foam Overhang Area

Spray Foam Rim

18" Mgf. Floor Truss

Spray Foam Rim

18" Mgf. Floor Truss

Timberline 30yr. Shingles 15# felt 1/2" OSB Sheathing

12 Mfg. Engineered Truss System

6

18" Mgf. Floor Truss

Spray Foam Rim

1'-6 3/4"

IWS to 24" inside Wall Line

Spray Foam Rim

5'-8 1/16"

9'-1 1/8"

10" core-filled CMU Pedastal Stone Pavers Concrete Slab 4" min. Stone veneer

1'-6 3/4"

18" Mgf. Floor Truss

Spray Foam Rim

2-1/2" Crown (Front Onlu) 5/4 x 6" Trim 5/4 x 2" Bead

Simpson CCOQ welded 3/16" x 4" Sq. steel tube post 91.5"+/- plate to plate (field measure before fabrication)

LP Smartside Sheathing (3-ply total)

3/4" T&G Subfloor

18" Mgf. Floor Truss

2'-4"

3/8" Anchor bolts w/nut & washer 7x7" 1/4" steel plate welded

2x12" Header

9'-10 1/4"

6'-3"

Built up Concrete Porch 4'-6 3/8"

5/8" Sheetrock

9'-3 3/8"

4 mil. Poly VB 5/8" Sheetrock

8'-9"

Truss Girder Per Manufacturer

8'-1 5/8"

Simpson CCOQ welded 3/16" x 4" Sq. steel tube post 118.5"+/- plate to plate (field measure before fabrication)

Permacast Column non-bearing

Simpson CCOQ welded 4" Sq. steel tube post

Limestone Cap

4"

Spray Foam Rim

1/2" L anchors w/nut & washer 7x7" 1/4" steel plate welded Adjustment nut (grout full) 1c. 10" Half High Corner 1c. 10" Conc Corner Blk. -core filled

#5 Re-bar embedded in Fnd.

Roof Edge 5/4 x 4" Smart Trim 1x8" Smart Trim 2x8" Sub Fascia Smart Trim Soffit Vent

4 mil. Poly VB 5/8" Sheetrock

5/4 x 6" Trim Window Trim (Typical)

Permacast Column wrap

5/4 x 2" Bead 5/4 x 6" Trim

Concrete window well

Spray Foam Rim

DATE:

3/4" T&G Subfloor 18" Mgf. Floor Truss

7/10/2014

Spray Foam Rim

5/8" Sheetrock

4" Conc. slab

2x6 Treated Sill Sill sealer "J" Bolts

Conc. Blk. Plan View

12" Concrete walls 2" Insulfast 4 mil. poly VB 1/2" Sheetrock

REAR PORCH POST DETAIL

4" concrete slab 6 mill Poly V.B. 4" - 3/4 rock bed

6" Curb Blk.

GARAGE POST SECTION

6'

1'

13'-0 3/4"

4'-1"

4'-1" 40'

16'-9 1/4"

SCALE: No Scale:

4" concrete slab 6 mill Poly V.B. 4" - 3/4 rock bed

8x16" Frost Ftg. 4" DrainTile 8x20" Frost Ftg.

2x6" Treated Sill w/ Sill Sealer Metal "J" Bolt

10"

10'-11 1/4"

12" Concrete walls 2" Insulfast 4 mil. poly VB 1/2" Sheetrock 8x18" Frost Ftg.

5'-7 3/8"

8x 24x24 Frost ftg.

LP Smartside siding 1/2" Ply. sheathing House Wrap 2x6" SPF Studs 16" o.c. R19 Batt Insul. 4 mil poly VB 1/2" Sheetrock Cap Trim TBD 1x10" Treated 4 Mil Poly VB

7x7" 1/4" steel plate welded

9'

4'-2"

12" dia. Conc. pier Min.

3'-6"

8

R50 Blown Insulation

Girder Truss Skewed 30 degrees

4" Perimeter DrainTile 8x20" Frost Ftg.

1'

SOUTH WINDOW WELL

SHEET:

10'-3"

MAIN NORTH SECTION

© 2014 ChiefExperts.com All Rights Reserved. Prin ng for personal use is acceptable. Distribu on and Reproduc on for others is prohibited without wri en permission from ChiefExperts.com, Inc.

01-3

12" Concrete walls 1-1/2" Foam Ins. 2x Furred Walls 24" o.c. 4 mil. poly VB 1/2" Sheetrock

952-236-4427

PROJECT DESCRIPTION:

Z = Up and -Down or Front to -Back on your Screen

Think in terms of CAD program not house building program

Y = Top to -Bo om of Screen

SHEET TITLE:

X = -Le and Right on Screen

Mastering Chief Architect X6 Session 2 of 14 by: Dan Baumann

Use Transform/Replicate Object

NO. DESCRIPTION:

BY:

Thinking in Terms of CAD will make your drawing process go faster

DATE:

Learn to Think in terms of CAD - X, Y, Z

3. Drawing in CAD Detail Windows

DATE: 7/10/2014 SCALE:

Chief is a CAD Program © 2014 ChiefExperts.com All Rights Reserved. Prin ng for personal use is acceptable. Distribu on and Reproduc on for others is prohibited without wri en permission from ChiefExperts.com, Inc.

SHEET:

01-4

Everything Starts With A CAD Polyline

BY:

Windows Are Many Boxes

Wall Boxes

Molding Polyline Boxes

Foo ng Boxes

All 3D Elements Are Based On Polylines

952-236-4427

PROJECT DESCRIPTION:

Convert Polyline

Slab Boxes

NO. DESCRIPTION:

Floor Boxes

Everything you draw is based on a Polyline or Polyline Shape

Slab Boxes

Ceiling Boxes

SHEET TITLE:

Overhang a Combina on of Boxes

Roof Boxes at an Angle

Mastering Chief Architect X6 Session 2 of 14 by: Dan Baumann

3D Item in a Box

DATE:

Everything in Chief is Based on CAD Polylines

DATE:

Virtually All 2D CAD Items can be Converted to 3D

7/10/2014

All Items In Chief Start As a CAD Polyline

© 2014 ChiefExperts.com All Rights Reserved. Prin ng for personal use is acceptable. Distribu on and Reproduc on for others is prohibited without wri en permission from ChiefExperts.com, Inc.

SCALE:

SHEET:

01-5

Resize

BY:

Marquee Tools

SHEET TITLE:

Arc Placement Tools (hint: It's Easy to Convert a Line to an Arc)

NO. DESCRIPTION:

Default Move

Convert View to a CAD Detail

Grid Snaps On/Off

Set Current CAD Drawing Layer

All Snaps On/Off

952-236-4427

Angle Snaps On/Off

PROJECT DESCRIPTION:

Bumping/Pushing

Store all Plan CAD Details Here

Overview of the Interface

Concentric Jump & CAD Se ngs Fillet Box & Polyline Corners

Mastering Chief Architect X6 Session 2 of 14 by: Dan Baumann

Polyline Tool Arc Tools - (hint: Convert Line) Circles and Ovals Polyline Box and Shapes Spline Tool CAD Defaults

DATE:

Overview of the CAD Items in Chief

Color On/Off Show Sheet

Point Tool

The EDIT Toolbar (See Next Page)

OnScreen Line Weight On/Off Print Preview Temp Dimensions On/Off Edit Polyline Parts Show Arc Centers

DATE: 7/10/2014 SCALE:

Reference Grid On/Off SHEET:

© 2014 ChiefExperts.com All Rights Reserved. Prin ng for personal use is acceptable. Distribu on and Reproduc on for others is prohibited without wri en permission from ChiefExperts.com, Inc.

01-6 No Scale:

Transform Replicate SHEET TITLE:

Mul ple Copy

Move Item To Front Break CAD Line (3) Trim Items (Use Fence) Extend items (Use Fence) Turn CAD Lines into Splines

952-236-4427

PROJECT DESCRIPTION:

Make Parallel/Perpendicular Point to Point Snap Add To Library Center Selected Reflect About Object

Mastering Chief Architect X6 Session 2 of 14 by: Dan Baumann

Copy and Copy in Place

Overview of the Interface tools when you Select something

NO. DESCRIPTION:

BY:

DATE:

Overview of the Edit Toolbar

Alignment and Distribute Tools Create Hole In Slab Plan Info, Coordinates

Polyline Union (Make Outline) Polyline Union (Leave Middle) Polyline Union (Leave Edge) Convert CAD Items Make CAD Box Cloud Object Convert Line to Arc/Arc to Line

Chamfer Inside and Outside Corner Fillet Outside and Inside Corner, Join Ends, Remove Points Join 2 Lines and Clean Up Mul ple Points Layer Proper es For Selected Item Record WalkThrough Along Path Draw Shape and Make Fence

© 2014 ChiefExperts.com All Rights Reserved. Prin ng for personal use is acceptable. Distribu on and Reproduc on for others is prohibited without wri en permission from ChiefExperts.com, Inc.

DATE: 7/10/2014 SCALE:

SHEET:

01-7 No Scale:

Group Selec ng saves me 952-236-4427

Purge CAD Block to Reduce File Size and Increase Plan Speed

Mastering Chief Architect X6 Session 2 of 14 by: Dan Baumann

Select All = Space Bar

Select Icon, Hold Shi Key and Marquee Select Those Items

PROJECT DESCRIPTION:

Select Icon To Be Part of Specific Marque Select

SHEET TITLE:

NO. DESCRIPTION:

BY:

DATE:

Selec ng and Grouping Items

Naming a CAD Block Preferences - Edit DATE:

7/10/2014 SCALE:

SHEET:

© 2014 ChiefExperts.com All Rights Reserved. Prin ng for personal use is acceptable. Distribu on and Reproduc on for others is prohibited without wri en permission from ChiefExperts.com, Inc.

01-8

BY:

DATE:

Pu ng It all Together to Create a Cross Sec on 5

FUR OUT WALL FLUSH TO CEILING

8'-1 1/8"

16'-5 5/8"

(VERIFY)

3'-10"

JAMES HADRIE TYPE SIDING TYVEK VAPOR BARRIER 1/2" OSB SHEATHING R-19 SPRAY FOAM INSULATION 2' X 6" STUDS 16" OC VAPOR BARRIER 1/2" DRYWALL

2 - 2" x 10" HEADERS

8'-1 1/8"

WRAP POSTS WITH DECORATIVE WOOD FINISH

10'-7 7/8"

12

11'-4"

1'-5"

WRAPPED OVERHANG AND FASCIA VENTILATION TO CODE

2.5

12

3'

6" x 6" LAM BEAM POSTS SUPPORTED TO FOUNDATION

TJI RIM JOIST SPRAY IN RIM JOIST FOAM INSULATION SILL SEAL 2" X 6" TREATED PLATE "J" BOLT 4'0" OC

3/4' PLYWOOD FLOOR SHEATHING GLUED AND SCREWED EXISTING FLOOR JOISTS

NEW FOUNDATION WALLS 6 - CRS, 12'x8" CMU VAPOR BARRIER COATING SPRAY FOAM INSULATION

GRADE

2' CONCRETE FLOOR WITH VAPOR BARRIER

3'-6"

EXISTING FOUNDATION WALL CORE FILL AREA BELOW NEW POST SUPPORTS

11-7/8" LPI 15 FLOOR JOISTS 16" OC - ADD BLOCKING PER MANUFACTURER

GRADE

3'-6"

12" RIM JOIST BOLTED TO EXISTING RIM JOIST WITH 2 - 3/8" x 4" LAG BOLTS 24" OC METAL JOIST HANGERS TO SUPPORT NEW FLOOR JOISTS

SOLID BLOCKING BELOW POSTS

8" X 20' CONCRETE FOOTING WITH 2- REE BAR

CrossN Sec on From Scratch with the 2D CAD Tools

Lot size 50' x 100'

03 Room Addition tied into 2 Story House

15'-9"

Adiro nd ack Ch air 2

air k Ch ac nd iro Ad

9'-1"

Ranch (curved)

Ranch (curved)

Ranch (curved)

Ranch (curved)

Ranch (curved)

19'-3"

ir Cha dack Adiron

UP

22'-11"

Deck Lounge

952-236-4427

Max 3' overhang permitted on roof eave and cantilever side porch is acceptable per GCBC.

Ad Ranch (curved)irond ack Ch air 2

Building line setbacks: 8' sides 10' rear 25' front

SHEET TITLE:

4 - 1-3/4" x 11-7/8" LAM BEAM HEADERS (VERIFY)

EXISTING FLOOR JOISTS

3'-6"

5/8" DRYWALL

2.5

7 1/2"

Using the Tools to Create a Sec on

12

PROJECT DESCRIPTION:

6'-8"

5

TRUSSESS PER MANUFACTURER 24" OC

Mastering Chief Architect X6 Session 2 of 14 by: Dan Baumann

ROOF SHINGLES TAR PAPER ROOF COVERING TO CODE ICE AND WATER SHIELD TO CODE VENTILATION TO CODE

NEW ROOF TRUSSES PER MANUFACTURER 12

NO. DESCRIPTION:

10"

EXISTING ROOF

Adirondack Loveseat

34'

12'' 303 7/8''

12'' 164''

176''

431 1/8''

115 7/8''

18 3/4'' 109 1/8''

125 5/8'' 2 1/4''

2'-10"

176''

2'-10"

585 7/16''

10'-4"

2 1/4''

3/4'' 127 1/8'' 303 7/8''

431 1/8''

10'-7"

17'

10'-7"

121 1/8''

125 1/8''

10'-7"

17'

175 1/4''

4'

7'-11"

34'-1"

2'-3"

B50136 FHB2136L

2'

61'-7"

King (arch)

16'

Sconce SB392230 (double) 8DB2420 Uti litarian Faucet Bamboo Chair W2D2461 W38421William Towel B27136 Ring

16'-7"

Beaded Frame B32136

Corner Shower Pan

7'-11"

SB3922 (double) 1'-9" UtiSconce Classic Waste Basket litarian Faucet Corner ShowerEnclosure Faucet FHB21134L William Towel RingW36361

ste r (cl Baskassic et )

Cla

B50136

Elevator Panel

FHB16136L

1'-6"

176''

Bu tto n Pi llow

Contemporary Dresser Frame (long)

7'-7" 3'-7"

10'-2" 2068

Pillow

Pillow

BCB39136 Towel Holder 6' Trend

4'-1"

5'-5"

12'-5"

5'-5" B49136

ssicTP Ho 6'-1" B40136 Wa lde

7'-2"

Corner elongated (34" fromcorner to seat end)

B40136 DCW193619R

11'-11"

UP

Daybed

Pillow

3068

3068

3'-2"

Euro

6'-6"

4'-9"

To recess light in stair well

3x10 joists 16" OC

Pillow

Sunburst Mirror

Closet Shelf w/ Rod

7'-3"

WasherDryer (curved (curved) frontU93177R loading)

Circular Frame B34136

4'

Pillow

1'-6"

Contemporary Dresser Frame (long)

3068

3068

2068

2068

8'-3"

2668

SB3530 Faucet (flair)

Towel Ring (rectangular)

Dresser 3

25'-3"

2'

4'-11" DCU222990L

3068

12'-6"

3x10 joists 16" OC

A/C Return

2'-8" 5'

2968

3'-8"

Elongated Toilet

4'-4"

4'

Towel Ring (rectangular)

7'-8"

3"

3'-3"

Beveled Mirror (vert)

3068

Jacuzzi J1S6032 BLX

Trend Towel Holder

3068

Euro

15'-9"

4'-9"

3068

Contemporary Dresser

2868

4'-4"

2020FX

7'-2"

Dresser 1

12'

Beaded Frame

Queen (craftsman)

ir Cha

3x10 joists 16" OC

man Otto Frame Spring

B3632

Euro

Beveled Mirror (horiz) Bowfront Dresser

12'-4"

Classic Waste Basket TP Holder (classic) W2427R

5068

Gatto

2'

15'-8"

2020FX

W2736

ir Cha Frame Spring

Contemporary Dresser

5068

176''

10'-2"

38'-7"

DATE: 7/10/2014

3068 2020FX Outdoor Compressor Unit

4'

3052SH

14'

4'-10"

0" FLOOR HEIGHT

Ranch (curved)

Ranch (curved)

Ranch (curved)

Ranch (curved)

6'-1"

0" FLOOR HEIGHT

SCALE:

Ranch (curved)

14'-1"

7'-8" Ranch (curved)

3068

Outdoor Compressor Unit

Create an Info Sec on Before Modeling the Building to Get The Info You Need © 2014 ChiefExperts.com All Rights Reserved. Prin ng for personal use is acceptable. Distribu on and Reproduc on for others is prohibited without wri en permission from ChiefExperts.com, Inc.

SHEET:

01-9

If you need help, I'm there for you! 952-236-4427

Mastering Chief Architect X6 Session 2 of 14 by: Dan Baumann

Can You Tell What's Being Built Here?

PROJECT DESCRIPTION:

SHEET TITLE:

NO. DESCRIPTION:

BY:

DATE:

Thanks for A ending - Now It's Time for Q&A

DATE: 7/10/2014 SCALE:

SHEET:

© 2014 ChiefExperts.com All Rights Reserved. Prin ng for personal use is acceptable. Distribu on and Reproduc on for others is prohibited without wri en permission from ChiefExperts.com, Inc.

01-10