GB Application Can be used in conjunction with: Pressurized storage heaters, thermally & hydraulically controlled instantaneous heaters and low-pressure displacement water heaters.

Pressure range:

Flush piping system prior and after installation of fitting thoroughly (considering EN806) Refer to the dimensional drawing on fold-outⅠ. Refer to the installation step guide fig. [1-5] The cold water supply must be connected on the right and the hot water supply on the left. Open cold and hot water supplies and check connections for leak tightness.

560mm 22 1/16"

m . 5m 7 4 ∅ 7/8" ∅1

147mm 5 13/16" 150mm- 155mm 5 7/8"-6 1/8" H24mm H 15/16"

Shut off cold and hot water supply! Replace thermostatic cartridge, see fig. [6] Lever out handle cap (A); Remove screw (B) using a cross-head screwdriver. Take out handle set (C). Remove screw (D) using a 2.5 mm Allen key, and remove fixation base (E), washer (F), handle (G) and ring (H).

∅72mm ∅2 13/16"



Thermostatic Concentric Mixer with Transparent Soap Dish VENTA SHOWER

73mm 2 7/8" 44mm 1 3/4" G1/2B

Maintenance

8mm 5/ 16" 86mm 3 3/ 8" 55mm- 65mm 2 3/16"-2 9/ 16"

G1/ 2

114mm 4 7/16"

Installation

m 0m 2" 19 1/ ∅ 7 ∅

Temperature --Hot water inlet (maximum) 90℃ Correct operation suggestion: --Hot water inlet temperature 55 ℃≤T≤65℃ --Recommended (energy saving): 60℃ --Cold water inlet temperature T ≤25℃ Water connection: Cold-Right Hot-Left

Dear Customer, We want to ensure that you get long-lasting satisfaction and pleasure from your fitting. Therefore, please read the following care instructions because damage to the surface and underlying material resulting from improper treatment is not covered by warranty. Do not use any abrasive sponges or scouring agents for cleaning. We also advise you not to use cleaning agents containing solvent or acid, limescale removers, household vinegar and cleaning agents with acetic acid in them. They are aggressive to the surface and will leave your fitting dull and scratched. As the formutations of commercially available cleaning agents frequently charge, we cannot guarantee they will provide the gentle care our fitting deserves. Clean the fitting with a little soap and a moist cloth only, then simply rinse off and wipe dry. You can avoid lime spots by drying the fitting each time it is used.

725mm 28 9/ 16"

Product Care 0. 2 bar 5 bar 16 bar

1500mm 59 1/16"

Minimum flow pressure: Maximum operating pressure: Air leakage pressure

ES104

Use a 48mm wrench to unscrew nut (Ⅰ) anti-clockwise. Replace cartridge (J). Reassemble in reverse order.

G1/ 2B



1

ES104

2

Remove the fixation base.

5 2.

m

5

Dismantle the mixer par ts shown.

m

Operate the product for a couple of minutes, varying both temperature and volume to determine correct operation.

6

Replace the thermostatic car tridge.

J

I

H

G

FE

RP551189

2. 5mm

Draw lines for Step 3 in accordance with the hole positions on the fixation base. Drill holes onto installation wall and fix the base. 560mm 22 1/ 16"

∅6mm ∅1/4"

RP381048

The distance should be decided based on the user's height and convenientce . Suggested height is 1.1 m. (43 5/16'')

RP027386 RP9703078

RP078003 RP020001 RP032221 RP9703079

300mm 11 13/ 16"

55- 65mm 2 3/16"-2 9/ 16" 150- 155mm 5 7/ 8"-6 1/8"

4

Body

Installation position

Connect the mixer's water inlets and outlet connector to pipes in wall. Use a spanner to tighten nuts to 35Nm (minimum).

RP426004

Min1180mm Min46 7/ 16"

RP301000

D 2.5mm

7

Adjust handle to correct position when temperature is at 38C. The car tridge is at 38C when the dot and groove/line are aligned.

1.1mm 43 5/ 16"

3

RP202221

CB A

Install the escutcheon plate, then handle par ts, and shower set.

RP020239 RP027090 RP062038 RP071058 RP075016 RP024287 RP530076 RP055013 RP044539 RP027381 RP025042 RP518000 RP027126 RP036120 RP058433 RP027128 RP034094 RP044218 RP024276 RP043030 RP024201 RP038331-91 RP020103 RP027002 RP034091 RP040000 RP024159 RP020041 RP063092 RP044935- 90 RP103061

RP058458

The flow restrictor is only needed when water pressure is above 5bar or where the hot water heater cannot keep up with the flow rate.

Flow Restrictor Installation position for flow restrictor

RP026000

2. 5mm 2.5mm