80×80×38mm 80W

Report 2 Downloads 58 Views
Splash proof Fan 80mm

80W

Splash proof Fan ■ Features

Splash proof and dust resistant ・Protection class IP55* water and dust resistant performance. Maintains safe operation even in harsh environments.

Large air flow and high static pressure ・Maximum air flow : 3.7 m3/min ・Maximum static pressure : 440 Pa

Energy-saving and low noise ・Power consumption : 36 W ・Sound pressure level : 63 dB(A)

※“IP55”is a protection specification for protection against water sprays and dust.  It is based on IEC (International Electrotechnical Commission) and JIS (Japanese Industrial Standards) and specified as follows.  Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment;  complete protection against contact. Water projected in jets against the enclosure from any direction shall have no harmful effect.

80×80×38mm ■ Specifications Model No.

9WV0848P1H001(0011)

Rated Voltage [V]

48

Operating PWM Rated Current Rated Input Rated Speed Voltage Range Duty Cycle -1 [V]

[%]

[A]

40.8 to 52.8

100 0

0.75 0.15

Note2)

[W]

36 7.2

Air Flow

Static Pressure

SPL

[min ] [m3/min] [CFM][Pa] [inchH2O][dB(A)]

9,700 4,500

3.7 1.72

131 60.8

440 94.7

1.77 0.38

63 43

Operating Temperature [℃]

Life Expectancy

Note3) [h]

40,000/60℃ −10 to +70 (70,000/40℃)

Note1 : The numbers in ( ) represent ribless models. Note2 : PWM Frequency:25kHz

Note3: Expected life at 40 degreeC ambient is just reference value.

■ Common Specifications □ Material ・・・・・・・・・・・・・・・・・・・・・・・・・・ Frame: Plastics (Flammability: UL94V-0) , Impeller: Plastics (Flammability: UL94V-1) □ Life Expectancy ・・・・・・・・・・・・・・・・・・・ Varies for each model (L10: Survival rate: 90% at 60℃, rated voltage, and continuously run in a free air state) □ Motor Protection System ・・・・・・・・・・ Current blocking function and reverse polarity protection □ Dielectric Strength ・・・・・・・・・・・・・・・・ 50/60 Hz, 500VAC, 1 minute (between lead conductor and frame) □ Sound Pressure Level (SPL) ・・・・・・・・ Expressed as the value at 1m from air inlet side □ Operating Temperature ・・・・・・・・・・・ Varies for each model (Non-condensing) +red ○ ーblack Sensor: yellow Control: brown □ Lead Wire ・・・・・・・・・・・・・・・・・・・・・・・・ ○ □ Mass ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Approx. 235g

80mm

□ Storage Temperature ・・・・・・・・・・・・・・ −30℃ to +70℃ (Non-Condensing)

80W ■ Air Flow and Static Pressure Characteristics

・ Operating Voltage Range

・ PWM Duty Cycle

1.6

1.2

(inch H2O) (Pa) 500 2.0

DC 48V

PWM Duty Cycle 100%

400

→ Static Pressure

→ Static Pressure

(inch H2O) (Pa) 500 2.0

300

50% 0.8

200

0.4

100

0

0%

0

2

1 0

20

40

60

3

4 (m3 /min)

80 100 120 140 (CFM)

300

0.8

200

0.4

100

0

40.8V

0

2

1 0

20

40

60

3

9,700min-1

8,000 7,000 6,000 5,000 4,000 3,000 2,000 1,000

PWM Duty Cycle(%)

9WV0848P1H001(0011)

100

4 (m3 /min)

80 100 120 140 (CFM)

9WV0848P1H001(0011)

9,000

Speed(min-1)

1.2

9WV0848P1H001(0011)

Voltage:48V DC PWM Frequency:25kHz

0

48V

→ Air Flow

10,000

0

52.8V

400

→ Air Flow

■ PWM Duty - Speed Characteristics Example

11,000

1.6

PWM Duty Cycle 100%

80×80×38mm ■ PWM Input Signal Example VIH=4.75V to 5.25V

Input Signal Wave Form

VIL=0V to 0.4V

T1 T ×100 PWM Frequency 25(kHz)= 1 T PWM Duty Cycle(%)=

VIH

Source Current ( Isource ) : 1mA Max. at control voltage 0V

VIL

Sink Current ( Isink ) : 1mA Max. at control voltage 5.25V Control Terminal Voltage : 5.25V Max. ( When control terminal is opened )

T1

When the control lead wire is open, speed is same as one at 100% PWM duty cycle.

T

Fan speed could be controlled by PWM input signal of either TTL input or open collector, drain input.

■ Connection Schematic + ○

Inside of DC fan

DC fan input voltage

PWM Input Signal

Control

Isource Isink

− ○

■ Specifications for Pulse Sensors Output circuit : Open collector VCE=+60V MAX. Ic=10mA MAX.[VOL=VCE(SAT)=0.4V MAX.]

Inside of DC fan + ○

Sensor

Pull-up resistor

+60V MAX.

Ic=10mA MAX.

Sensor output − ○

Output waveform (Need pull-up resistor) T1∼4≒(1/4)T0

In case of steady running (One revolution)

N=Fan speed(min-1)

T0 T1 VOH VOL 0V

T2

T1∼4≒(1/4)T0=60/4N(sec)

T3

T4

■ Dimensions (unit : mm) (with rib) 4-φ4.3±0.3 Lead Wire AWG24 UL1430 80±0.5 71.5±0.3

+30 300 0

(10) (4)

(4) 38±0.5

71.5±0.3 80±0.5

Air Flow Direction

Rotating Direction

■ Reference dimension of mounting holes and vent opening (unit : mm) Inlet Side, Outlet Side 4-φ4.5

78.5

90

71.5±0.3

φ

71.5±0.3 78.5

Notice

●The products shown in the catalog are subject to Japanese Export Control Law. Diversion contrary to the law of exporting country is prohibited. ●To protect against electrolytic corrosion that may occur in locations with strong electromagnetic noise, we provide fans that are unaffected by electrolytic corrosion. 1-15-1, Kita-otsuka, Toshima-ku,Tokyo 170-8451, Japan. PHONE :+ 81 3 3917 5151       http://www.sanyodenki.co.jp

CATALOG No. C0981B001 ‘11.04