Particulate Sampling Size-selective Samplers
Sioutas Personal Cascade Impactor the Sioutas Impactor
Ad antage! Choose the personal-size Sioutas Impactor for the highly efficient collection of airborne particles in five size ranges:
> 2.5 μm 1.0 to 2.5 μm 0.50 to 1.0 μm 0.25 to 0.50 μm < 0.25 μm The advantage is the efficient collection of fine and ultrafine particles. Recent epidemiological studies show that fine and ultrafine particles may have greater pulmonary inflammatory potency than larger particles and associate increased morbidity and mortality with increased exposure to these particles. The Sioutas Impactor is the only personal impactor that precisely separates and collects coarse, fine, and ultrafine particles simultaneously.
More Information Misra, C., et. al., “Development and Evaluation of a Personal Cascade Impactor Sampler (PCIS),” Journal of Aerosol Science, 33, 2002, pp. 1027-1047
ABOUT Filters for Sioutas Impactor The Sioutas Impactor uses four 25-mm filters (required) and one 37-mm filter (optional) for sampling. The 25-mm PTFE filters act as collection substrate and the optional 37-mm PTFE filter is the final collection filter (after-filter). SKC recommends PTFE filters ‡ for use in the Sioutas Impactor to minimize particle bounce and preserve unstable compounds. Coated collection substrate may be used if desired, however, a coating is not necessary and can interfere with chemical analysis. For more information on SKC filters, see pages 73-83.
100
Separates Coarse, Fine, and Ultrafine Particles Precise particle separation • Particle size cut-points: 2.5 μm, 1.0 μm, 0.50 μm, and 0.25 μm • The only personal impactor that efficiently samples coarse, fine, and ultrafine particles simultaneously • Maintains high collection efficiency even at high particle concentrations
Optimized at a 9 L/min flow rate with low pressure drop for 24-hour sampling • Improves analytical sensitivity • Minimizes non-detectable samples
Preserves unstable compounds • Chemically inert collection substrate • No impaction grease to contaminate sample
Minimal particle bounce and internal wall losses
See page 22 for details. Sample Time: Sample Rate: Sample Pump: Sample Media: Tubing:
Varies 9 L/min Leland Legacy 25 and 37-mm filters 3/8-inch ID
Suitable for indoor and outdoor sampling** Size-fractionated samples can be analyzed gravimetrically, chemically, and microscopically
Leland Legacy Sample Pump The compact, portable, and batteryoperated Leland Legacy Sample Pump provides 9 L/min flow rate for optimum Sioutas Impactor performance. For more information, see pages 22-23.
Small and lightweight • Suitable for personal or area sampling
The patented† personal-size Sioutas Cascade Impactor* separates and collects airborne particles in five size ranges: > 2.5 μm, 1.0 to 2.5 μm, 0.50 to 1.0 μm, 0.25 to 0.50 μm, and < 0.25 μm. When used with PTFE filters,‡ the Sioutas Impactor is highly efficient at collecting particles without the use of impaction grease or substrate coatings and at retaining unstable compounds for size-fractionated chemical analysis. Use the Sioutas Impactor with the Leland Legacy Sample Pump at 9 L/min to ensure precise particle separation at the specified cut-points. Particles above each cut-point are collected on a 25-mm filter in the appropriate stage with particles below 0.25 μm collecting on the 37-mm after-filter (optional). The small, lightweight Sioutas Impactor simply clips to a worker’s collar or lapel for personal sampling and is also suitable for area sampling.
Description Sioutas Personal Cascade Impactor Tubing, Tygon, 3/8-inch ID fits Sioutas Impactor and Leland Legacy pump, 3 meters (10 feet)
Cat. No. 225-370 225-1351
Filters for Sioutas Impactor Description After-filter, PTFE,‡ 37 mm, 2.0 μm (optional) Collection Filter (filter for 4 stages), PTFE,‡ 25 mm, 0.5 μm, required * Developed by Dr. Constantinos Sioutas of the University of Southern California in partnership with the Mickey Leland National Urban Air Toxics Research Center (NUATRC)
www.skcltd.com
Cat. No. 225-1709 225-2708
Qty. 50 100
† U.S. Patent No. 6,786,105 (University of Southern California) ‡ Back pressure on PTFE filters can vary within the same lot. ** Requires special provisions; see product operating instructions
SKC Ltd.
Phone: +44 (0)1258 480188
Particulate Sampling Size-selective Samplers
IMPACT Sampler Sharp size selection for PM10, PM2.5, or PM Coarse (10-2.5) Ideal for environmental PM sampling and indoor air studies Use with any pump at 10 L/min — Leland Legacy recommended
Featu r DPS Sed in the ys see pa tem! g e 24
Compact design Higher flow rate provides increased sensitivity Convenient operation • Removable filter cassette for fast media changes • Disposable ready-to-use pre-oiled impaction discs reduce particle bounce — no cleaning or greasing • Included rain cover protects sampler during outdoor use • Optional quick-mount bracket secures sampler virtually anywhere
IMPACT and the Leland Legacy Sample Pump Sample Time: Sample Rate: Sample Pump: Sample Media: Tubing:
Varies 10 L/min Leland Legacy 47-mm filter (requires impaction substrate) 3/8-inch ID
The patented‡ SKC IMPACT single-stage inertial impactor is designed for the efficient collection of PM10, PM2.5, or PM Coarse (10-2.5) in ambient air. A sampling pump operating at 10 L/min draws PM through the impactor; larger particles are captured on a disposable pre-oiled impaction disc while smaller particles collect on a 47-mm filter. IMPACT media changes are as easy as removing the filter cassette and replacing it with one already loaded. The impaction disc fits into the top of the cassette. IMPACT’s higher flow rate requirement provides increased sensitivity for low levels of PM. For sampling efficiency data, go to www.skcinc.com/instructions/Modular_Impactors_Poster.pdf.
IMPACT Sampler Cat. No. IMPACT Sampler includes filter cassette, calibration adapter, and rain cover for sampler; requires collection media and impaction substrate sold separately; see below PM2.5 225-392 PM10 225-390 PM Coarse includes 2 filter cassettes 225-3911 Replacement Filter Cassette 225-396 Filter Cassette Opener 225-397 Mounting Bracket 225-399 Collection Filters for IMPACT Sampler (not supplied with IMPACT or DPS System) Select a filter based on your application; required for sampling Quartz Filters, 47 mm, Tissuquartz, 432 μm thick 225-1823 PTFE Filters,§ 47 mm, 2.0-μm pore size, with PMP support ring 225-1747 Impaction Substrate Impaction Discs, 37 mm, pre-oiled, ready to use, disposable, 225-395 Required for sampling. Limited shelf-life 225-395A Accessories PM Coarse Ring includes filter cassette, adapts IMPACT PM10 to an IMPACT PM Coarse 225-3912 Petri Dish Slide, for filter transport 225-2-01
While IMPACT can be used with any pump at 10 L/min, partnering IMPACT with the Leland Legacy sample pump provides a highly efficient sampling system. The quiet, fully programmable Leland Legacy pump can provide a constant 10 L/min flow rate for 24 hours making it ideal for environmental monitoring or indoor air studies. For more information on the Leland Legacy Sample Pump, see pages 22-23. IMPACT and the Leland Legacy Sample Pump are both included in the DPS Sampler System on page 24.
Qty. ea ea ea ea ea ea
Convenient All-in-one Filter Cassette Impaction disc press fits into top of filter cassette Filter cassette top
25 50
47-mm collection filter
25 50
Perforated support disc
ea 100
Filter cassette bottom
§ Back pressure on PTFE filters can vary within the same lot. ‡ U.S. Patent No. 7,334,453
For a deployable particulate sampling system featuring the IMPACT Sampler, see the DPS System on page 24. SKC Inc.
Phone: +1-724-941-9701
www.skcinc.com
101