APOLLO capri vertical technical specification 54mm 35mm 5mm

35mm 5mm

5mm

5mm

1750mm

35mm

Db

35mm

B

C single - rear view single - top view

1750mm

1800mm

Dt

B

C double - rear view

A single - side view

A double - side view

double - top view

ADDITIONAL INFORMATION

CAPRI VERTICAL DIMENSIONS (mm) MODEL HEIGHT

1800

Material

E235 grade steel

Width of radiator

(No. sections x 75) + 5

Steel tube measurements

11mm x 70mm

Tube width

70

Steel thickness

Tube depth

11

Section width (tube + space)

75

Maximum working pressure

(A)

95

Testing pressure

5.2 bar/520 kPa

(B)

55

Maximum working temperature

95°C

(C)

Width of rad

Wall to front of rad

Collector Tubes

1.5mm 1.5mm 4 bar/400 kPa

Wall to pipe centres

Side entry

Tapping centres

Side entry Bottom entry

N/A

Pipe centres

Side entry

Width plus valves N/A

TEMPERATURE

Bracket positions

Top

(Dt)

40

Bottom

(Db)

5

FACTORS FOR DIFFERENCES BETWEEN MEAN WATER TEMPERATURE AND ROOM TEMPERATURE IN °C AND °F OTHER THAN 50 °C (90 °F)

Bottom entry

N/A

Bottom entry

The thermal outputs expressed at ΔT=50k comply with European regulation EN 442-2

5 °C

0.050

600

10 °C

0.123

10 °F

0.057

0.209

20 °F

0.142

CAPRI SINGLE WHITE 1800 HIGH WEIGHTS AND VOLUMES (per section) Model width mm

300

450

13.20

19.80

26.40

15 °C

4.20

6.30

8.40

20 °C

0.304

30 °F

0.240

17.40

26.10

34.80

25 °C

0.406

40 °F

0.348

632

948

1264

30 °C

0.515

50 °F

0.466

35 °C

0.629

60 °F

0.590

40 °C

0.748

70 °F

0.721

CAPRI SINGLE CHROME 1800 HIGH WEIGHTS AND VOLUMES (per section)

45 °C

0.872

80 °F

0.858

Model width mm

Dry weight (A) Kg Water content (B) Litres Working weight (A+B) Kg Outputs: Watts

ΔT=50k

Dry weight (A) Kg Water content (B) Litres Working weight (A+B) Kg Outputs: Watts

ΔT=50k

300

450

600

50 °C

1.000

90 °F

1.000

13.20

19.80

26.40

55 °C

1.132

100 °F

1.147

4.20

6.30

8.40

60 °C

1.267

110 °F

1.298

17.40

26.10

34.80

65 °C

1.406

120 °F

1.454

507

760

1013

70 °C

1.549

130 °F

1.613

CAPRI DOUBLE WHITE 1800 HIGH WEIGHTS AND VOLUMES (per section) Model width mm Dry weight (A) Kg Water content (B) Litres Working weight (A+B) Kg Outputs: Watts

ΔT=50k

300

450

600

25.80

38.80

51.70

7.80

11.80

15.70

33.60

50.60

67.40

980

1470

1960

75 °C 1.694 140 °F 1.776 TO APPLY THE FACTORS SHOWN IN THE TABLE TO OUR QUOTED OUTPUTS. MULTIPLY THE QUOTED OUTPUT BY THE CHOSEN OPERATING FACTOR TO GIVE THE OUTPUT

APOLLO capri horizontal technical specification

5mm

single - side view

WIDTH OF RAD LESS 70mm

35mm

Db

5mm

75mm

C

single - rear view

B

A WIDTH OF RAD LESS 70mm

5mm

C

double - side view 5mm

75mm

B

Dt

double - rear view

35mm

A

CAPRI HORIZONTAL DIMENSIONS (mm)

MODEL WIDTHS SINGLE 1800

MODEL WIDTHS DOUBLE 1000, 1200, 1400, 1800 HEIGHT OF RADIATOR

(No. sections x 75) + 5

Tube width

Wall to front of rad

Wall to pipe centres

Side entry

Bottom entry

Tapping centres

Side entry

Bracket positions

Top

Pipe centres

Double

75

75

70

Tube depth

Section width (tube + space)

Single

Bottom entry Side entry

Bottom entry Bottom

70

11

(A)

55

(B)

26

(C)

11

N/A N/A

95 66

Width of rad less 70mm N/A

Width of rad less 70mm

(Dt)

75

(Db)

75

75 75

CAPRI SINGLE WHITE 1800 WIDE WEIGHTS AND VOLUMES (per section)

Model height mm

Dry weight (A) Kg

Water content (B) Litres

Working weight (A+B) Kg Outputs: Watts

ΔT=50k

300

450

600

13.20

19.80

26.40

632

948

1264

4.20

17.40

6.30

26.10

8.40

34.80

CAPRI DOUBLE WHITE 1800 WIDE WEIGHTS AND VOLUMES (per section)

Model height mm

Dry weight (A) Kg

Water content (B) Litres

Working weight (A+B) Kg Outputs: Watts

ΔT=50k

300

25.80 7.80

33.60

980

450

38.80 11.80

50.60

1470

600

51.70

15.70

67.40

1960

ADDITIONAL INFORMATION

Material

Steel tube measurements Steel thickness

Maximum working pressure Testing pressure

Collector

Tubes

Maximum working temperature

E235 grade steel 11mm x 70mm 1.5mm 1.5mm

4 bar/400 kPa

5.2 bar/520 kPa 95°C

The thermal outputs expressed at ΔT=50k comply with European regulation EN 442-2

TEMPERATURE

FACTORS FOR DIFFERENCES BETWEEN MEAN WATER TEMPERATURE AND ROOM TEMPERATURE IN °C AND °F OTHER THAN 50 °C (90 °F) 5 °C

0.050

20 °C

0.304

10 °C

15 °C

25 °C

30 °C

35 °C

40 °C

45 °C

50 °C

55 °C

60 °C

65 °C

70 °C

0.123

10 °F

0.057

0.406

40 °F

0.348

0.209

0.515

0.629

0.748

0.872

1.000

20 °F

30 °F

50 °F

60 °F

70 °F

80 °F

90 °F

1.132

100 °F

1.549

130 °F

1.267

1.406

110 °F

120 °F

0.142

0.240

0.466

0.590

0.721

0.858

1.000

1.147

1.298

1.454

1.613

75 °C 1.694 140 °F 1.776 TO APPLY THE FACTORS SHOWN IN THE TABLE TO OUR QUOTED OUTPUTS. MULTIPLY THE QUOTED OUTPUT BY THE CHOSEN OPERATING FACTOR TO GIVE THE OUTPUT