Channel Nuts Without Spring - Kelly and Hayes

Report 0 Downloads 106 Views
Previous Page

Return to TOC

Next Page

Nut Size Wt/100 pcs Thread Lbs (kg)

P3006-0832

#8 -32

P3006-1024

#10 -24 1

P3006-1420 P3007

⁄4" -20

5

⁄16" -18 3

P3008 P3009

7

⁄16" -14

P3010

1

P3013

1

Channel nut Part number P1012 P1023 P1024 Channel nut Part number

⁄2" -13 ⁄2" -13

5

⁄8" -11

20 9.1 3 ⁄4" -10 20 9.1 7 ⁄8" -9 20 9.1 Nut Size Wt/100 pcs Thread Lbs (kg) 5

P4023

3

⁄8" -11 ⁄4" -10

1

P1008T

3

P1010T

1

P4010T

1

UNIST RU T

P4908

11 5.0 11 5.0

Nut Size Wt/100 pcs Thread Lbs (kg)

P1006T1420

Channel nut Part number





















P5000

P5500

For Use With Channel P1000, P1100, P3300, P4000 P2000, P3000 P4100

































































⁄4" -20 ⁄8" -16 ⁄2" -13 ⁄2" -13

Nut Size Thread 3

⁄8" -16

7 3.2 10 4.5 12 5.4 8 3.6 Wt/100 pcs Lbs (kg) 17.5 7.9

P5000

P5500

























Telestrut System



For Use With Channel Nut Size Wt/100 pcs P1000, P1100, Thread Lbs (kg) P2000, P3000

P4012

Channel nut Part number UNISTRU T

⁄8" -16

6 2.7 6 2.7 6 2.7 6 2.7 9 4.1 9 4.1 11 5.0 8 3.6



Nuts & Hardware

Channel nut Part number

⁄4" -20



General Fittings

P3016-1420



Pipe/Conduit Supports

1



Electrical Fittings

#10 -24



Concrete Inserts

P3016-1024

P5500

11⁄4" Framing System

#8 -32

P5000

For Use With Channel P3300, P4000, P4100 –















P5000

P5500

For Use With Channel P1000, P1100, P3300, P4000 P2000, P3000 P4100

































P5000

P5500





For Use With Channel P1000, P1100, P3300, P4000 P2000, P3000 P4100





Framing System

P3016-0832

2 0.9 2 0.9 4 1.8 4 1.8

13⁄16"

#6 -32

Fiberglass System

P3016-0632

For Use With Channel P1000, P1100, P3300, P4000 P2000, P3000 P4100

Special Metals

Nut Size Wt/100 pcs Thread Lbs (kg)

PrimeAngle System

Channel nut Part number

15⁄8" Channel

Channel Nuts Without Spring

Product Index

Double Conveyor Adjusting Nut

■ Acceptable for use Nuts & Hardware

79

Goto to Main PDF Menu

GENERAL FITTINGS

Electrical Fittings

Pipe/Conduit Supports

General Fittings

Nuts & Hardware

1 5/8" Channels

FOR 15⁄8" (41 MM) WIDTH SERIES CHANNEL

Page Flat Plate Fittings

82

Ninety Degree Fittings

86

Angular Fittings

93

“Z” Shape Fittings

94

“U” Shape Fittings

96

Wing Shape Fittings

101

Post Bases Brackets and Braces Beam Clamps Trolleys Special Application Fittings

Index

Spec. Metals & Fiberglass

13⁄16"

Framing System

11⁄4" Framing System

Concrete Inserts

End Caps Partition and Display Fittings

105 106 112 122 124 126 127

MATERIAL Fittings, unless noted, are made from hot-rolled, pickled and oiled steel plates, strip or coil, and conform to ASTM specifications A575, A576, A635, or A36. The fitting steel also meets the physical requirements of ASTM A570 GR 33. The pickling of the steel produces a smooth surface free from scale. Many fittings are also available in stainless steel, aluminum and fiberglass. Consult factory for ordering information. FINISHES Fittings are available in: PermaGreen II (GR), electro-galvanized

(EG), conforming to ASTM B633 Type III SC1; Hot-dipped galvanized (HG), conforming to ASTM A123 or A153 and plain (PL). APPLICATION All parts drawings illustrate only one application of each fitting. In most cases many other applications are possible. The channels shown in the illustrations are P1000, 15⁄8" square, except where noted otherwise. All 9⁄16" diameter holes use 1 ⁄2" x 15⁄16" hex head cap screws and 1⁄2" nuts – P1010, P4010 or P5510 – depending on the channel used. Nuts and bolts are not included with the fitting and must be ordered separately.

DESIGN BOLT TORQUE BOLT SIZE FOOT LBS. N.m

1⁄4" 20

5

⁄8"

5⁄16" 18

3⁄8" 16

1⁄2" 13

11

3⁄4" 10

6

11

19

50

100

125

8

15

25

70

135

170

DIMENSIONS Imperial dimensions are illustrated in inches. Metric dimensions are shown in parenthesis or as noted. Unless noted, all metric dimensions are in millimeters and rounded to one decimal place. DESIGN LOAD Design load data, where shown, is based on the ultimate strength of the connection with a safety factor of 2.5, unless otherwise noted.

80

Return to #12 TOC