CSR4, CSR8 HigH Output

Report 2 Downloads 46 Views
CSR4, CSR8 High Output

4' or 8' Industrial / 1 or 2-Lamp T8HO, T12HO

Project Information Project Name

Type

Catalog No.

Date

Housing

Die formed steel with knockouts for stems or chain hangers.

Features • • • • • • •

Reflector

Available in 4' and 8' lengths 5% uplight distribution reflectors Telescopic spring loaded lampholders 2½" lamp spacing For individual or continuous row mounting Channel ends double as joiners Two 4' reflectors with reflector aligners supplied on 8' fixtures

Die embossed with transverse ribs for maximum rigidity. Available with apertures for uplight. Ballasts

Energy efficient, thermally protected, automatic resetting, Class P, high power factor, sound rated A, unless otherwise specified.

Ordering Information CSR Model

Size 4 4' 8 8'

No. of Lamps IN Cross Section 1 One 2 Two

Certification

All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924.

Example CSR8-296HO-U-EPU-GLR



CSR Industrial

Finish

White painted parts are treated with a five stage phosphate bonding process and finished after fabrication with a minimum 90% reflective gloss baked enamel. LSR and M4R reflectors specular room side, Mill finish aluminum top surface.

– Lamp Type 48HO 4', T12: High Output 96HO 8', T12: High Output 96T8HO 96", T8: High Output

Accessories (Order Separately) CSZTF Zip Tee Hanger - flush mounting on T-Bar ceiling CSZT Zip Tee Hanger - 1½" spacer on tee bar ceiling CSTH Slide Clamp Tong Hanger S18 18" Stem, canopy and 8° aligner SS18 18", 45° Swivel Stem & Canopy ITB4 Close Mounting on T-Bar ceiling CSHC 14" Chain Hanging Assembly CSRWG4 4' Wire Guard (two required for 8' fixture) OS1K Occupancy Sensor Kit, 120/277/347V, One Relay1

EP

– Reflector Type

Ballast

U Apertured EP Electronic T12 or Reflector for 5% T8 Rapid Start Uplight (Std.) For a specific ballast ST Solid Reflector, No vendor, show as option. Uplight LSRU Apertured Alum Reflector with Specular Silver Finish LSR Solid Top Alum Reflector with Specular Silver Finish M4RU Apertured Alum Reflector with 95% Reflective Specular Silver Finish M4R Solid Top Alum Reflector with 95% Reflection Specular Silver Finish

– Options

Voltage U 120V-277V 347 347V

GLR GMF EL BC

Fast Blow Fuse Slow Blow Fuse Emergency Battery Pack Branch Circuit Plug-on Wiring System (See options section for details.) PAF Paint After Fabrication NYC NYC Compliant NYCU NYC Compliant, Union Label

1 Use programmed start ballast. Not recommended for use with an instant start. For more occupancy/daylight harvesting sensor accessories see Technical section.

Page 1/2 Rev. 07/15/13 © 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com

industrials / CSR4, CSR8 high output

CSR4, CSR8 High Output

4' or 8' Industrial / 1 or 2-Lamp T8HO, T12HO

Photometric Data CSR8-296HO-U-LE CSR Industrial 96" X 11" Industrial with Baked White Apertured Reflector R-2S110-TP 0.95 F96T12/CW/HO 9000 237 N/A 0º = 1.27  90º = 1.45 Length: 8.00 Width: 0.92 Height: 0.00

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

Zone

Lumens

Lamp

Fixt.

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

3371 5669 10770 14595 388 507 582 597 15192

18.7 31.5 59.8 81.1 2.2 2.8 3.2 3.3 84.4

22.2 37.3 70.9 96.1 2.6 3.3 3.8 3.9 100.0

Energy Data

Indoor Candela Plot

RCR

Coefficients of Utilization (%) 70 90 81 74 67 61 57 52 49 45 42

80 50 30 86 82 74 68 64 57 56 49 50 42 45 37 40 33 37 29 34 26 31 24

10 78 63 51 43 36 31 27 24 22 19

70 88 79 71 65 59 55 51 47 44 41

70 50 30 84 80 72 66 63 56 55 48 49 41 44 36 40 32 36 29 33 26 30 24

10 77 62 50 42 36 31 27 24 21 19

50 79 68 60 53 47 42 38 35 32 29

50 30 77 64 54 46 40 35 31 28 26 23

10 74 60 49 41 35 30 27 24 21 19

0 0 66 54 45 37 32 28 24 21 19 17

84.4%

Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

61 Non-Compliant $3.93 based on 3000 hrs. and $0.08 per KWH

AVG. LUMINANCE (Candela/Sq. M.)

4200

RC RW 1 2 3 4 5 6 7 8 9 10

Total Luminaire Efficiency

Average Luminance Angle

Luminaire Data Luminaire

Test 10124 Test Date 1/8/03

Zonal Lumen Summary

2100

0 30 40 45 50 55 60 65 70 75 80 85

0.0

22.5

45.0

67.5

90.0

6099 6061 5972 5917 5847 5755 5672 5475 5183 4724 3925 2635

6099 6184 6182 6184 6205 6260 6388 6617 6833 6990 6932 6142

6099 6410 6693 6908 7169 7471 7748 8018 8373 7538 6536 5135

6099 6667 7203 7518 7881 8129 8488 8672 8157 7295 6089 4246

6099 6768 7388 7737 8070 8340 8746 8734 8009 7222 5929 3641

2100

4200

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Dimensional Data

Mounting Accessories 96"

45⁄8" A

3"

A

B

B

A

A

B

A

A

48" 48"

45⁄8" A

B

3"

A

241⁄8"

B

A

A

B

A

B

A

CSZTF Zip-Tee Hanger

CSZT Zip-Tee Hanger

CS2 Ceiling Spacer

S18 Stem and Canopy Stem

CSTH Slide Clamp Tong Hanger

CSHC Chain Set

47/16" 35⁄8" 21⁄2" 11"

A - 7/8" Diameter Knockout B - 5⁄16" x 1⁄2" hole

NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.

Page 2/2 Rev. 07/15/13 © 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com

industrials / CSR4, CSR8 high output