direct steam table mount steam jacketed “oyster cooker”

Report 6 Downloads 20 Views
DIRECT STEAM TABLE MOUNT STEAM JACKETED “OYSTER COOKER”

D

M odel

Ca p a ci t y

TOC-1

Oyster Cooker

1 Qt.

TOC-2

Oyster Cooker

2 Qt.

O P E R AT I O N S H A L L B E BY : Electrically, self-generating closed steam system equipped for operation on: 208 VAC, 3 Phase, 50/60 Hz 230 VAC, 3 Phase, 50/60 Hz 240 VAC, 3 Phase, 50/60 Hz O P T I O N A L I T E M S AT E X T R A C O ST :

S P E C I F I C AT I O N S : Shall be a Solaris Model ____________________________ , stainless steel type 304 satin finished. Cooker operating at a max. 15 psi (103kPa). Oyster Cooker will tilt on kettle trunnions having lifetime “O” ring seals. Ease of tilting is provided with a right tilt handle and a pouring lip is provided to direct fluid flow. Oyster Cooker is supported on kettle trunnions by left and right legs and a centre rigid leg provides level support. The right leg shall have a steam control valve to regulate steam entry into the jacket. The left leg provides a means for removing condensate formed in the jacket. REQU I REM ENT:

Type 316 stainless steel liner for high acid content products 3" (76 mm) draw-off valve 2" (50 mm) dairy draw off valve 3" (76 mm) dairy draw off valve High wattage heaters for faster heating 24 kw on 40, 60, 80 gallon 33 kw on 60, 80, 100 gallon Double pantry faucet with swing spout Single pantry faucet with swing spout Spring assist cover 20, 30, 40 gallon 380, 415 or 480 VAC, 3 phase, 50/60 Hz 220/380, 240/415 VAC, 3 phase, 4 wire Etched gallon markings Etched litre markings Two piece hinged cover ACCESSORI ES:

Remote steam source - max. 15 psi (103kPa). Steam trap for each oyster cooker. One safety relief valve for one or more units connected to the same steam supply line. (See reverse). Steam shut off valve in steam line convenient and adjacent to unit.

Triple basket assembly Perforated strainer for draw off Graduated measuring stick Strainer hook Solid strainer for draw off

If steam source is a considerable distance away from oyster cooker, condensate will likely form in the steam line and will require a ball float trap for removal of condensate.

Customer Service (570) 497-5477 - Fax (888) 388-6017 - www.solarissteam.com

DETAILS AND DIMENSIONS SERVICE CONNECTIONS – STEAM S UPPLY: 1/2" IPS for incoming steam at a minimum of 5 PSI

(34kPa) and a maximum of 15 PSI (103kPa).

– CONDENSATE RETURN: 1/2" IPS condensate return from cooker may be connected to condensate return line.

SI

– STEAM CONTROL VALVE: Regulates flow of steam into cooket jacket.

DIMENSIONS MODEL TOC-1 TOC-2

CAPACITY 1 quart 0.95 litres 2 quart 1.9 litres

UNITS inches mm inches mm

A 8.25 210 10 254

B 17.88 454 17.88 454

C

D

7.5 191 8.5 216

12 305 12.12 308

E 2.25 57 2.63 67

F 1.88 48 2.375 60

G 11.25 286 12.38 314

INSTALLATION REQUIREMENTS: Remote steam source, steam trap, safety relief valve and steam shut off valve. NOTE: It is advisable to plumb a steam shut off valve in the steam line ahead of the safety valve.

IN (mm) 04/01

As continued product improvement is a policy of Solaris, specifications are subject to change without notice.

3106R1