energizer 321 product datasheet - Energizer Technical Information

Report 6 Downloads 125 Views
PRODUCT DATASHEET 1-800-383-7323 1-800-383-7323 / USA USA/CAN 1-800-383-7323 / CANADA www.energizer.com

ENERGIZER 321

SILVER OXIDE

Specifications

Industry Standard Dimensions mm (inches)

Chemical System:

Silver Oxide (Zn/Ag2O)

Nominal Voltage: Typical Capacity: Capacity Test: Typical Weight: Typical Volume: Impedance (40 Hz):

1.55 Volts 15 mAh* (to 1.2 volts) 94K ohm continuous drain at 21°C 0.28 grams (0.01 oz.) 0.07 cubic centimeters (0.004 cubic inch) 30 to 40 ohms

* Varies according to the applied load, temperature, and cutoff voltage. 6.80 (0.268)

4.60 (0.181) Ref. Typical

6.60 (0.260)

1.65 (0.065)

Cross Section

1.45 (0.057)

R0.8 (0.031) Ref. Typical

E

1.60 (0.063) Ref.

0.13 (0.005) Minimum Ref. Permissible deflection from a flat

Gasket Can Separator

SO L

0.03 (0.001) Minimum Ref. (applies to top edge of gasket or edge of crimp, whichever is higher)

Anode Cap Gel Anode

ET

1.40 (0.055) Ref.

Cathode

DESIGNED FOR USE ON CONTINUOUS LOW DRAIN

Temperature Characteristics

Typical Performance at 21°C (70°F)

Typical Performance at Low Discharge Rates

1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0

Service Effects 125 100 75 50 25 0 -20

0

200

Schedule

Continuous

400 600 Service, Hours

800

1000

Typical Drains at 1.55V (milliamperes)

(ohm)

Cutoff 1.2V (hours)

0.016

94K

938

Load

0 20 Temperature (C)

40

Storage Effects 100 Service (%)

Voltage, CCV

Schedule: Continuous Typical Drain @1.55V: 0.016 milliamperes Load: 94K ohm

Service (%)

OB

Typical Discharge Characteristics

0 C

90

20 C

80 70

40 C

60 0

2

4 6 8 Storage Time (yrs)

10

12

Important Notice

This datasheet contains typical information specific to products manufactured at the time of its publication. ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty. Form No. EBC - 4309H

Page 1 of 1