7350 NW 35th Terrace, Miami, Florida 33122 Customer Service: 1-866-999-2355 1-800-383-7323 Phone: 1-305-371-9200 Fax: / USA 1-305-371-9400 1-800-383-7323 / CANADA www.microbattery.com

ENERGIZER 329

SILVER OXIDE

Specifications

Industry Standard Dimensions mm (inches)

Chemical System:

Silver Oxide (Zn/Ag2O)

Nominal Voltage: Typical Capacity: Capacity Test: Typical Weight: Typical Volume: Impedance (40 Hz):

1.55 Volts 39 mAh* (to 1.2 volts) 22K ohm continuous drain at 21°C 0.58 grams (0.02 oz.) 0.15 cubic centimeters (0.009 cubic inch) 55 to 65 ohms

* Varies according to the applied load, temperature, and cutoff voltage.

7.90 (0.311)

4.40 (0.173) Ref. Typical

7.62 (0.300)

3.10 (0.122)

Cross Section

2.85 (0.112)

R1.15 (0.045) Ref. Typical

2.80 (0.110) Ref. 2.55 (0.100) Ref. Anode Cap Gel Anode Gasket Can Separator

0.25 (0.010) Maximum Ref. Permissible deflection from a flat 0.03 (0.001) Minimum Ref. (applies to top edge of gasket or edge of crimp, whichever is higher)

Cathode

DESIGNED FOR USE ON CONTINUOUS LOW DRAIN

Typical Discharge Characteristics

Temperature Characteristics

Typical Performance at 21°C (70°F)

Service Effects

125 Service (%)

100

1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0

75 50 25 0 -20

0

150

Schedule

Continuous

300 Service, Hours

450

600

Typical Drains at 1.55V (milliamperes)

(ohm)

Cutoff 1.2V (hours)

0.070

22K

557

Load

0 20 Temperature (C)

40

Storage Effects

100 Service (%)

Voltage, CCV

Schedule: Continuous Typical Drain @1.55V: 0.070 milliamperes Load: 22K ohm

Typical Performance at Low Discharge Rates

0 C

90

20 C

80 70

40 C

60 0

2

4 6 8 Storage Time (yrs)

10

12

Important Notice

This datasheet contains typical information specific to products manufactured at the time of its publication. ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty. Form No. EBC - 4310F