F Pilot Operated Check Valves

Report 2 Downloads 75 Views
Pilot Operated Check Valves

19 Series Cylinder Position Holding

Right Angle

Models with Push-to-Connect Fitting Port Size Port 2 Port 1# (tube fittings) (male threads)

Valve Model Number

Port 12

CV 1-2

2-1

Tightening Torque Max. Ft-lb (Nm)

5/32”

1/8

1958A1115

10-32 UNF

0.4

0.4

11.06 (15)

1/4”

1/8

1958A1120

10-32 UNF

0.4

0.4

11.06 (15)

1/4”

1/4

1958A2120

10-32 UNF

0.8

0.7

14.75 (20)

3/8”

1/4

1958A2130

10-32 UNF

0.8

0.7

14.75 (20)

3/8”

3/8

1958A3130

10-32 UNF

1.2

1.3

22.13 (30)

4 mm

G1/8

D1958A1140*

M5

0.4

0.4

7.38 (10)

6 mm

G1/8

D1958A1160*

M5

0.4

0.4

7.38 (10)

8 mm

G1/8

D1958A1180*

M5

0.4

0.4

7.38 (10)

6 mm

G1/4

D1958A2160*

M5

0.8

0.7

8.85 (12

8 mm

G1/4

D1958A2180*

M5

0.8

0.7

8.85 (12)

10 mm

G1/4

D1958A2110*

M5

0.8

0.7

8.85 (12)

8 mm

G3/8

D1958A3180*

M5

1.2

1.3

14.75 (20)

10 mm

G3/8

D1958A3110*

M5

1.2

1.3

14.75 (20

# Port 1 tubing size in inches (”) or millimeters (mm). * BSPP port threads. Valve Dimensions – inches (mm) 1.7 (41)

F4

1.9 (48)

0.5 (13)

Port Size 1/8

0.7 (17)

Port Size 1/4

Pilot Signal Port

2.2 (55)

Pilot Signal Port

Port 2

0.9 (22)

Port Size 3/8

Pilot Signal Port

Port 2

Port 1

Port 1

Port 2

Port 1

4

4

3

3

3

2

2 1

1 0 0 2 P2 (bar)

3

4

5

6

7

8

G1/8 - 1/8 NPTF

(bar)

4

3

(bar)

4 (bar)

F

(bar)

Signal Pressure: The charts below show the minimum signal pilot port pressure to open the valve versus port 2 pressure (P2) when there is no pressure at port 1 (P1 = 0 bar).

2

0 0 2 P2 (bar)

3

4

5

6

7

8

G1/4 - 1/4 NPTF

0 0 2 P2 (bar)

2 1

1 3

4

5

6

7

8

G3/8 - 3/8 NPTF

0 0 2 P2 (bar)

3

4

5

6

OPTIONS Manual Trapped Pressure Relief Adapter

Manual Override

Port 1

Port 2

Port Threads

Model Number*

5/32

10-32 Manual Operated Check

NPT

1998A1015

M5

M5 Manual Operated Check

BSPP

D1998A1010

* Adapter threads into the signal port.

Valve Illustrated with Optional Manual Trapped Pressure Relief Adapter

STANDARD SPECIFICATIONS (for valves on this page): Construction: Poppet. Mounting Type: In-Line. Ambient/Media Temperature: 15° to 160°F (-10° to 70°C).

Flow Media: Filtered air. Operating Pressure: 15 to 150 psig (1 to 10.3 bar).

IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS, WARNINGS on the inside back cover.

F4.4

© 2016, ROSS CONTROLS®. All Rights Reserved.

Online Version Rev. 11/14/16

7

8

G1/2 - 1/2 NPTF