Area Lighting Wallighter® 175 (W1LR, W1SR, W1LG & W1SG)

imagination at work

Product Features For that extra security in an insecure world, GE Area Wallighters provide light were needed, on pathways, entrances, walkways, and building parameters. These area wallighters offer an attracitve, yet economical solution to those outdoor lighting needs where a wall-mounted fixture is the only practical choice.

Applications

Unique Features

• •

• • • • • •

Building perimeters, entrances, walkways and residential yards Loading docks and many other wall mounted area lighting applications

Housing • Two-piece die-cast aluminum housing

Rating •

/

1598 Listed Suitable for Wet Locations

Reflectors • Acrylic refractor or vandal-resistant polycarbonate refractor

Mogul (E39 standard) or medium base (E26 standard) sockets Standard and tamper resistant hardware included Thru-feed conduit entrance on side with built-in conduit clamps Front access to ballast when mounted Field installed Internal Glare Shield (IGS-WL175) available Magnapack packaging available

Ordering Number Logic Wallighter® 175 (W1LR, W1SR, W1LG & W1SG)

____ - __ - _ _ - _ _ _ - ___ - DB __ Light Source

Prod. ID

wattage

W1LR = Wallighter 175 (Mogul Base E39 Socket Standard without Lamp)

See Ballast and See Ballast and See Ballast and Photometric Photometric Photometric Selection Table Selection Table Selection Table

W1SR = Wallighter 175 (Medium Base E26 Socket Standard with Lamp) W1LG = Wallighter 175 (Mogul Base E39 without Lamp with Internal Glare Shield) W1SG = Wallighter 175 (Medium Base E26 with Lamp and Internal Glare Shield)

05 = 50 07 = 70 10 = 100 15 = 150 (55V)

E = Energy Act Compliant Pulse MH (EPMH) M = MH P = PMH S = HPS

Voltage

60Hz 0 = 120/208/ 240/277 Multivolt 1 = 120 2 = 208 3 = 240 4 = 277 5 = 480 C = 120x240x 277 (150W PMH only) D = 347 F = 120X347 T = 220

ballast type selection See Ballast and Photometric Selection Table

PE Function

Lens Type

1 = None For PE Kit, see Accessories 3 = Internal PE control*

A = Acrylic L = Polycarbonate*

A = Autoreg G = Mag-Reg with Grounded * Not available Socket Shell with multivolt H = HPF or 480V Reactor or Lag K = Hot Restart M = Mag-Reg N = NPF Reactor or Lag

* Not for car wash applications

IES Distribution type See Ballast and Photometric Selection Table

-

_ OPTIONs

color DB = Dark Bronze

SN2 = Short Non-cutoff Type II SN3 = Short Non-cutoff Type III

B = Time Delay Switched (Drop Lens only) F = Fusing (Not available with multivolt or dual voltage)

SN4 = Short Non-cutoff Type IV SS3 = Short Semi-cutoff Type III SS4 = Short Semi-cutoff Type IV MN4 = Medium Noncutoff Type IV

50Hz 6 = 220 Y = 240

Ballast and Photometric Selection Table All light sources are clear unless otherwise indicated.

Ballast Type/Voltage

Ballast Type/Voltage

60Hz 50Hz Light Wattage Source Multivolt 120 208 240  277 480 347, 120X347 220 220 240 W1LR Mogul Base Without Lamp 50 HPS H H, K, N H H 70, 100, 150(55V) HPS H, K G,H,K,M G,H,M G,H,M 175 MH A A A A 175 MH A A A A (Coated) W1SR MEDIUM BASE WITH LAMP 70, 100, 150(55V) HPS H, N H, N N/A N/A 70, 100, 150** PMH H*, N H, N, A H, N N/A 70, 100, 150** PMH H*, N H, N, A H, N N/A (Coated) 175 MH N/A N/A N/A N/A 175 MH N/A N/A N/A N/A (Coated) W1LG mogul base without lamp with internal glare shield 50 HPS H H, K, N H H 70, 100, 150(55V) HPS H G,H,K,M G,H,M G,H,M 175 MH N/A N/A N/A N/A (Coated) W1SG medium base with lamp with internal glare shield 70, 100, 150(55V) HPS H, N H, N N/A N/A 70, 100, 150** PMH H*, N H, N, A H, N N/A 70, 100, 150** PMH H*, N H, N, A H, N N/A (Coated) 175 MH N/A N/A N/A N/A 175 MH N/A N/A N/A N/A (Coated)

H G,H,M A A

N/A G,M A A

Acrylic

Polycarbonate

IES Photometric Distribution Curve Number Type 35-

IES Photometric Distribution Number Type 35-

H H A A

H N/A A A

H H,M A A

N/A H A A

SN4 SN4 SN4 SN4

178047 178047 178051 178049

SN4 SN4 SN4 SN4

178046 178046 178050 178048

H, N H H, N, A H, N H, N, A H, N

H, N H, N H, N

N/A N/A N/A

H,M N/A N/A

H N/A N/A

SN3 SN2 SN2

178053 178055 178057

SN3 SN2 SN2

178052 178054 178056

N/A N/A

N/A N/A

A A

A A

A A

A A

SN2 SN2

178055 178057

SN2 SN2

178054 178056

H H G,H,M G,M N/A N/A

H H A

H N/A A

H H,M A

N/A H A

C/F C/F C/F

C/F C/F C/F

SN4 SN4 SS4

178476 178476 178478

H, N H H, N, A H, N H, N, A H, N

H, N H, N H, N

N/A N/A N/A

H,M N/A N/A

H N/A N/A

C/F SN3 SN4

C/F 179122 179125

SS3 C/F C/F

178479 C/F C/F

N/A N/A

A A

A A

A A

A A

SN3 SS3

450685 450686

C/F C/F

C/F C/F

N/A N/A

NOTE: N/A = Not available. C/F = Contact Manufacturer *150W PMH Available in Tri-Volt Multivolt: 120X208X277V or 120X240X277V **150W PMH Only available in HPF-LAG (H) Ballast Type for 120 or 208 or 240 or 277V and Auto-Reg (A) in 120 or 277V

Product Dimensions KNOCKOUT FOR .75 in. (19 mm) CONDUIT

CRADLE FOR .75 in. (19 mm) CONDUIT

.686 in. (17 mm) DIA KNOCKOUT FOR PE KIT ASSEMBLY

4.000 in. (102 mm)

7.750 in. (197 mm)

.358 in. (9 mm) DIA KNOCKOUT (4 PLACES) .188 in. (5 mm) DIA KNOCKOUT FOR USE WITH 4.000 in. (102 mm) OCTAGON BOX (4 PLACES) 4.375 in. 1.375 in. (35 mm) MAX (111 mm) .625 in. (16 mm) MIN 6.344 in. (161 mm)

2.875 in. (73 mm)

12.875 in. (327 mm)

.150 in. (4 mm) .188 in. (5 mm) DIA KNOCKOUT FOR USE WITH 3.250 in. (83 mm) OCTAGON BOX (4 PLACES)

GASKET

D ATA

INTERNAL GLARE SHIELD OPTION

14.438 in. (367 mm)

.437 in. DIA (11 mm) DIA (2 PLACES)

8.000 in. (203 mm)

4.000 in. (102 mm)

.875 in. (22 mm) DIA

.188 in. (5 mm) DIA KNOCKOUT FOR USE WITH GEM-BOX

• Approximate Net Weight: 15-25 lbs (6-9 kgs) • Suggested Mounting Height: 8-20 ft. (3-7 M) • Effective Projected Area: 1.0 sq. ft. max. (0.09 sq. M max.)

GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com

1-8 8 8 - 6 9 - 4 3-533

GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand and logo are trademarks of the General Electric Company. © 2012 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.