Greengate Occupancy Sensor Guide

Report 21 Downloads 106 Views
Sensor Technologies Passive Infrared (PIR) Technology • •

Designed to detect motion from a heat-emitting source (such as a person entering a room) within its field-of-view and automatically switch lights ON and OFF. PIR sensors are considered line-of-sight sensors, meaning that the sensor must be able to have a direct line-of-light to the person making the motion.

Using this paper versus standard paper produced the following environmental benefits.

Based on Environmental Defense Fund Paper Calculator

Ultrasonic (US) Technology • • •

Ultrasonic sensors use the Doppler principle. These sensors produce low intensity, inaudible sound and detect changes in sound waves caused by motion. They are volumetric in nature and therefore not line-of-sight dependant. They are much more sensitive to smaller motions.

Dual Technology • • •

Dual Technology is the combination of PIR and Ultrasonic into one sensor and is the ultimate sensing solution available today. This pairing helps to eliminate false activations (both ON and OFF) thus saving additional energy use. Dual Technology sensors ensure the greatest sensitivity and coverage for tough applications without the threat of false triggers.

Number of Trees Saved

12

Total Energy Saved—Million BTU’s

7.9

Greenhouse Gas Reduction—lbs of CO2

4391

Gallons of Water Saved

4129

Solid Waste Reduction— lbs of Waste

683

Kilo-watt (kwh) Hours Saved

1702

MicroSet Self-Adjusting Technology • •

Continuously adjusts to conditions by adjusting sensitivity and Time Delay in real-time. By adjusting sensitivity and Time Delay automatically, the sensor is maximizing the potential energy savings that are available.

North America Headquarters 203 Cooper Circle Peachtree City, GA 30269 P: 800-553-3879 F: 800-954-7016

About Energy Codes

www.coopercontrol.com [email protected]

Cooper Controls Ltd Usk House, Lakeside, Llantarnam Park, Cwmbran, NP44 3HD. UK P: +44 (0)1923 495495 F: +44 (0)1923 867880

Canada 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: 905-507-4000 F: 905-568-7049

www.coopercontrol.com [email protected]

Energy costs and consumption continue to rise. Today, many energy codes and energy policies either require or incentivize the use of energy efficient lighting controls on commercial projects. ASHRAE 99.1-1999, 2001, 2004, 2007, 2010 In buildings over 5,000 square feet, all general lighting must be able to be automatically turned off. • Occupancy sensors can be used through out the building, in lieu of programmable timing, to meet the Automatic-Off requirement outlined in the ASHRAE standard. • In every building, regardless of size, ASHRAE requires that occupancy sensors be placed in classrooms, conference/meeting rooms, employee cafeterias and break rooms. As of December 30, 2010 The Department of Energy (DOE) recognizes the ASHRAE 2004 standard as the new national minimum.

LEED Green Building Rating System Both of the above ASHRAE requirements must be met by any project hoping to earn LEED certification. Lighting controls can contribute toward meeting a prerequisite and earning up to 24 percent or 24 of the 100 points available in LEED 2009. • Use occupancy sensors to earn LEED points by significantly improving the energy performance of the building.

Version 3.0

California Title 24 Automatic shut-off occupancy sensors must be installed in the following areas to turn off the lighting when a space is unoccupied: • • • •

Offices 250 sq. ft. or smaller Multipurpose rooms of less than 1000 sq. ft. Classrooms of any size Conference rooms of any size

Space Control - Requires individual control devices in spaces enclosed with floor to ceiling height partitions and include individual rooms for partitioned open offices. Light level reduction control - Requires simple switching strategies to reduce light levels by up to 50%. Bi-level occupancy sensors can also meet the requirements by offering 2 levels of control.

IECC • ASHRAE and Title 24 requirements must be met. • IECC 2003 & 2006, Occupants must be able to reduce lighting load in the space in a reasonably uniform pattern by at least 50%. Bi-Level occupancy sensors offering personal control can be used to comply with this mandatory requirement.

Cooper US, Inc. 600 Travis, Suite 5600 Houston, TX 77002 P: 713-209-8400 F: 713-209-8995 www.cooperindustries.com

ACC120033

Cooper Controls, Greengate, Novitas, PCI Lighting Control Systems, VisionTouch, VisionSwitch, MicroSet, Digita, ControlKeeper, LiteKeeper, IntelliRelay, NeoSwitch, TracKeeper, Revio, and Ineo are valuable trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to use Cooper Trademarks without the prior written consent of Cooper Industries.

Printed in USA

Greengate Occupancy Sensor Guide

Occupancy Sensor Application Guide Commercial Wall Switch Sensors

Commercial Line Voltage Fixture Mount

Commercial Line Voltage Ceiling Sensor

Commercial Low Voltage Wall/Corner Mount

OAWC-DT-120W

OAWC-P-009L-H

OAWC-P-120W

OEF-P-2MH0-MV-S

OAC-P-1500-DMV

OAC-P-1500-MV

OAC-P-0500-DMV

OAC-P-0500-MV

OXC-P-2MH0-R

OXC-P-1500-R

OAC-DT-2000

OAC-DT-1000

OAC-DT-0501

OAC-U-2000

OAC-U-1000

OAC-U-0501

OAC-P-1500

OAC-P-0500

VNLW-P-1001-MV-N-*

ONW-P-1001-RR7-*

ONW-P-1001-SP-*

ONW-P-1001-D347-*

ONW-P-1001-347-*

ONW-P-1001-DMV-*

ONW-P-1001-MV-*

ONW-D-1001-RR7-*

ONW-D-1001-SP-*

ONW-D-1001-DMV-N*

ONW-D-1001-MV-N-*

ONW-D-1001-MV-*

ONW-D-1001-DMV-*

Specification Grade OSW-U-0721-MV-*

OSW-P-0451-DMV-*

OSW-P-0451-MV-*

OSW-P-1001-MV-*

Commercial Grade

Commercial Low Voltage Ceiling Sensors

Specifications

Specifications Passive Infrared

Technology

Ultrasonic

Dual Technology

Mounting Coverage (sq. ft.)

1000

450

1000

1500

Manual

Self-Adjust

360°

500

1000

2000

500

1000

2000

120 or 277V

120 or 277V

120 or 277V

Not Required

15 sec to 2 hr

10-30 VDC

24 VAC

Required

RR7 Relay Required

Not Included

120 or 277V

347V

360°

1500

2MHO

360° up to 25’

Dual Technology Technology Wall/Corner Mount

Mounting

1200

90 Linear

1200

120°

180° 8 to 12’

120°

120 to 277V

10 to 30 VDC

Required

RR7 Relay Required

Not Required

Required

Not Required Included

Not Included

Included

Not Included

Included

Not Included

SP, True 3-Way, No Neutral Required

W, V, A

SP, 3-Way*, No Neutral Required

Dual Relay, 3-Way*, No Neutral Required

OAC-P0500-R

OAC-P-1500-R

OAC-U0501-R

OAC-U1000-R

OAC-U2000-R

OAC-DT0501-R

OAC-DT2000-R

SP, 3-Way*, Light Icon No Neutral

Dual Relay, 3-Way*, Light Icon, Fan Mode, No Neutral Required

SP, 3-Way*, Light Icon, EcoMeter

Dual Relay, 3-Way*, Light Icon, Fan Mode, EcoMeter

SP, Light Icon, EcoMeter

SP, 3-Way*, No Neutral Required, Light Icon, EcoMeter

Dual Relay, 3-Way*, No SP, 3-Way*, No Neutral Neutral, Light Required, Light Icon, EcoMeter Icon, EcoMeter

Dual Relay, 3-Way*, No Neutral Required, Light Icon, EcoMeter

SP, Light Icon, EcoMeter

SP, 3-Way*, Light Icon, EcoMeter Night Light

GOOD

BETTER

BEST

BEST

BEST

BEST

BETTER

BETTER

BETTER

BETTER

BETTER BETTER

GOOD

GOOD

Copy/File/Storage Room

BEST

BEST

BEST

BETTER

BEST

BEST

BEST

BEST

BEST

BEST

BEST

BEST

Commercial Line Voltage Ceiling Sensors BEST

GOOD

BEST

BEST

BETTER

BETTER

BETTER

BETTER

BETTER

BETTER

GOOD

GOOD

BEST

BEST

BEST

BEST

BEST

BEST

BEST

BEST

GOOD

GOOD

Hallway GOOD

GOOD

BETTER

BEST

BEST

BEST

BEST

Office Home Office Private Open Office w/Cubicles Parking Garage

GOOD GOOD

GOOD GOOD

GOOD GOOD

BETTER BETTER

BEST BEST

BEST BEST

BEST BEST

BEST BEST

BEST BEST

BEST

GOOD

GOOD

BEST

GOOD GOOD

GOOD GOOD

GOOD

GOOD

GOOD

GOOD

BETTER

BETTER

GOOD

GOOD

GOOD

BEST

BEST

BEST

Restroom Partitioned

BETTER

BEST

BEST

BEST

BEST

BEST

BEST

BETTER

BETTER

GOOD

GOOD

BEST

BEST

BEST

BEST

BEST

BEST

BETTER

BEST

BETTER

BEST

BETTER

BEST

GOOD

BEST

BEST BEST

BEST

BETTER

BETTER

BEST

BEST

BEST

GOOD

GOOD

GOOD

BEST

BEST

BEST

BEST

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

Cafeteria Classroom

BETTER

BEST

Computer Room

GOOD

BETTER

BEST

Conference Room

BEST

BEST

GOOD

BETTER

Copy/File/Storage Room BETTER

Hallway

BEST

Loading Dock

BETTER

BETTER

BETTER

BEST

BEST

BEST

GOOD

GOOD

GOOD

GOOD

GOOD

BEST

GOOD

GOOD

BETTER

BETTER

BETTER

BEST

BEST

BEST

GOOD

GOOD

GOOD

GOOD

GOOD

BEST

BEST

BEST

BEST

BEST

BEST

BEST

Office Executive

BEST

BEST

Office Home Office Private Open Office w/Cubicles Parking Garage

BEST

BEST

Refrigerated Storage

BEST GOOD

Applications Cafeteria High Ceiling

GOOD GOOD

Feature

Closet/Utility

BEST

Residential Room GOOD

BETTER

BEST BEST

BEST

BEST

GOOD BEST

GOOD

Restroom Non-Partitioned

BEST

Restroom Partitioned

BEST

Restroom Residential GOOD

GOOD

GOOD

GOOD

BEST

BEST

BEST

BEST

GOOD BEST

BEST

Warehouse Aisles

BETTER

BETTER

Warehouse Open

BETTER

BETTER

3-Way*: Lights will turn OFF automatically when sensor that detected motion last times out. SP: Single Pole Colors: W-White; V-Ivory; LA-Light Almond; A-Almond; G-Gray; B-Black Other specialty sensors available at www.coopercontrols.com

Commercial Low Voltage Wall/Corner Mount

GOOD

BEST

BEST

Fixture Mount

GOOD

BETTER

Stairwell

Environmental Operating Temperature/Humidity

Up to 5 sensors can be used per Switchpack

GOOD

BEST

Refrigerated Storage BETTER

OAWC-DT-120W- Photocell R BAS/HVAC Relay

BEST

BEST GOOD

GOOD

BEST

Loading Dock Office Executive

OAWC-P-009LH-R

BEST

BEST

Computer Room Conference Room

No Switchpack Required

BEST BETTER

BEST

OAWC-P-120W-R

Available Colors

Commercial Low Voltage Ceiling Sensors

BEST

Switchpack/Power Pack

32°F to 104°F (0°C to 40°C) / 20% to 90%, non-condensing

Up to 5 sensors can be used per Switchpack

Classroom BEST

Not Included

Voltage

Required

W

BEST BEST

Included

Included

W, V, LA

Commercial Wall Switch Sensors

BEST

Not Included

NEMA WD 7 Standard Tested Pattern Mounting Height (ft.) Time Delay

10 to 30 VDC

Not Required OAC-DT1000-R

Coverage (sq. ft.)

Adjustment

120 to 277V

-40°F to 125°F (-40°C to 52°C) / less than 95%, non-condensing

W, V, LA, G, & B

SP 3-Way*, No Neutral Required

up to 40’ Self-Adjust or Manual

120 to 347V

32°F - 104°F (0°C - 40°C) / 20 to 90%, non-condensing W, V, LA, G, B

8 to 12’

Self-Adjust

15 sec to 30 min

24 VAC

Cafeteria High Ceiling

Vending Room

500

180°

10-30 VDC

GOOD

Restroom Residential

2MHO

0 sec to 30 min

Cafeteria

Restroom Non-Partitioned

1500

Self-Adjust

15 sec to 30 min

Included

180°

Self-Adjust or Manual

Applications

Residential Room

Passive Infrared Fixture

8 to 12’

Manual

Environmental Operating Temperature/Humidity

Closet/Utility

Passive Infrared

Yes

BAS/HVAC Relay

Feature

500

180° 4’

Voltage

Available Colors

Dual Technology Ceiling

720

Time Delay Switchpack/Power Pack Photocell

Ultrasonic

Wall Switch

NEMA WD 7 Standard Tested Pattern Mounting Height (ft.) Adjustment

Passive Infrared

GOOD

Stairwell

BEST

Vending Room GOOD

Warehouse Aisle Warehouse Open

Occupancy Sensor Application Guide Commercial Wall Switch Sensors

Commercial Line Voltage Fixture Mount

Commercial Line Voltage Ceiling Sensor

Commercial Low Voltage Wall/Corner Mount

OAWC-DT-120W

OAWC-P-009L-H

OAWC-P-120W

OEF-P-2MH0-MV-S

OAC-P-1500-DMV

OAC-P-1500-MV

OAC-P-0500-DMV

OAC-P-0500-MV

OXC-P-2MH0-R

OXC-P-1500-R

OAC-DT-2000

OAC-DT-1000

OAC-DT-0501

OAC-U-2000

OAC-U-1000

OAC-U-0501

OAC-P-1500

OAC-P-0500

VNLW-P-1001-MV-N-*

ONW-P-1001-RR7-*

ONW-P-1001-SP-*

ONW-P-1001-D347-*

ONW-P-1001-347-*

ONW-P-1001-DMV-*

ONW-P-1001-MV-*

ONW-D-1001-RR7-*

ONW-D-1001-SP-*

ONW-D-1001-DMV-N*

ONW-D-1001-MV-N-*

ONW-D-1001-MV-*

ONW-D-1001-DMV-*

Specification Grade OSW-U-0721-MV-*

OSW-P-0451-DMV-*

OSW-P-0451-MV-*

OSW-P-1001-MV-*

Commercial Grade

Commercial Low Voltage Ceiling Sensors

Specifications

Specifications Passive Infrared

Technology

Ultrasonic

Dual Technology

Mounting Coverage (sq. ft.)

1000

450

1000

1500

Manual

Self-Adjust

360°

500

1000

2000

500

1000

2000

120 or 277V

120 or 277V

120 or 277V

Not Required

15 sec to 2 hr

10-30 VDC

24 VAC

Required

RR7 Relay Required

Not Included

120 or 277V

347V

360°

1500

2MHO

360° up to 25’

Dual Technology Technology Wall/Corner Mount

Mounting

1200

90 Linear

1200

120°

180° 8 to 12’

120°

120 to 277V

10 to 30 VDC

Required

RR7 Relay Required

Not Required

Required

Not Required Included

Not Included

Included

Not Included

Included

Not Included

SP, True 3-Way, No Neutral Required

W, V, A

SP, 3-Way*, No Neutral Required

Dual Relay, 3-Way*, No Neutral Required

OAC-P0500-R

OAC-P-1500-R

OAC-U0501-R

OAC-U1000-R

OAC-U2000-R

OAC-DT0501-R

OAC-DT2000-R

SP, 3-Way*, Light Icon No Neutral

Dual Relay, 3-Way*, Light Icon, Fan Mode, No Neutral Required

SP, 3-Way*, Light Icon, EcoMeter

Dual Relay, 3-Way*, Light Icon, Fan Mode, EcoMeter

SP, Light Icon, EcoMeter

SP, 3-Way*, No Neutral Required, Light Icon, EcoMeter

Dual Relay, 3-Way*, No SP, 3-Way*, No Neutral Neutral, Light Required, Light Icon, EcoMeter Icon, EcoMeter

Dual Relay, 3-Way*, No Neutral Required, Light Icon, EcoMeter

SP, Light Icon, EcoMeter

SP, 3-Way*, Light Icon, EcoMeter Night Light

GOOD

BETTER

BEST

BEST

BEST

BEST

BETTER

BETTER

BETTER

BETTER

BETTER BETTER

GOOD

GOOD

Copy/File/Storage Room

BEST

BEST

BEST

BETTER

BEST

BEST

BEST

BEST

BEST

BEST

BEST

BEST

Commercial Line Voltage Ceiling Sensors BEST

GOOD

BEST

BEST

BETTER

BETTER

BETTER

BETTER

BETTER

BETTER

GOOD

GOOD

BEST

BEST

BEST

BEST

BEST

BEST

BEST

BEST

GOOD

GOOD

Hallway GOOD

GOOD

BETTER

BEST

BEST

BEST

BEST

Office Home Office Private Open Office w/Cubicles Parking Garage

GOOD GOOD

GOOD GOOD

GOOD GOOD

BETTER BETTER

BEST BEST

BEST BEST

BEST BEST

BEST BEST

BEST BEST

BEST

GOOD

GOOD

BEST

GOOD GOOD

GOOD GOOD

GOOD

GOOD

GOOD

GOOD

BETTER

BETTER

GOOD

GOOD

GOOD

BEST

BEST

BEST

Restroom Partitioned

BETTER

BEST

BEST

BEST

BEST

BEST

BEST

BETTER

BETTER

GOOD

GOOD

BEST

BEST

BEST

BEST

BEST

BEST

BETTER

BEST

BETTER

BEST

BETTER

BEST

GOOD

BEST

BEST BEST

BEST

BETTER

BETTER

BEST

BEST

BEST

GOOD

GOOD

GOOD

BEST

BEST

BEST

BEST

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

Cafeteria Classroom

BETTER

BEST

Computer Room

GOOD

BETTER

BEST

Conference Room

BEST

BEST

GOOD

BETTER

Copy/File/Storage Room BETTER

Hallway

BEST

Loading Dock

BETTER

BETTER

BETTER

BEST

BEST

BEST

GOOD

GOOD

GOOD

GOOD

GOOD

BEST

GOOD

GOOD

BETTER

BETTER

BETTER

BEST

BEST

BEST

GOOD

GOOD

GOOD

GOOD

GOOD

BEST

BEST

BEST

BEST

BEST

BEST

BEST

Office Executive

BEST

BEST

Office Home Office Private Open Office w/Cubicles Parking Garage

BEST

BEST

Refrigerated Storage

BEST GOOD

Applications Cafeteria High Ceiling

GOOD GOOD

Feature

Closet/Utility

BEST

Residential Room GOOD

BETTER

BEST BEST

BEST

BEST

GOOD BEST

GOOD

Restroom Non-Partitioned

BEST

Restroom Partitioned

BEST

Restroom Residential GOOD

GOOD

GOOD

GOOD

BEST

BEST

BEST

BEST

GOOD BEST

BEST

Warehouse Aisles

BETTER

BETTER

Warehouse Open

BETTER

BETTER

3-Way*: Lights will turn OFF automatically when sensor that detected motion last times out. SP: Single Pole Colors: W-White; V-Ivory; LA-Light Almond; A-Almond; G-Gray; B-Black Other specialty sensors available at www.coopercontrols.com

Commercial Low Voltage Wall/Corner Mount

GOOD

BEST

BEST

Fixture Mount

GOOD

BETTER

Stairwell

Environmental Operating Temperature/Humidity

Up to 5 sensors can be used per Switchpack

GOOD

BEST

Refrigerated Storage BETTER

OAWC-DT-120W- Photocell R BAS/HVAC Relay

BEST

BEST GOOD

GOOD

BEST

Loading Dock Office Executive

OAWC-P-009LH-R

BEST

BEST

Computer Room Conference Room

No Switchpack Required

BEST BETTER

BEST

OAWC-P-120W-R

Available Colors

Commercial Low Voltage Ceiling Sensors

BEST

Switchpack/Power Pack

32°F to 104°F (0°C to 40°C) / 20% to 90%, non-condensing

Up to 5 sensors can be used per Switchpack

Classroom BEST

Not Included

Voltage

Required

W

BEST BEST

Included

Included

W, V, LA

Commercial Wall Switch Sensors

BEST

Not Included

NEMA WD 7 Standard Tested Pattern Mounting Height (ft.) Time Delay

10 to 30 VDC

Not Required OAC-DT1000-R

Coverage (sq. ft.)

Adjustment

120 to 277V

-40°F to 125°F (-40°C to 52°C) / less than 95%, non-condensing

W, V, LA, G, & B

SP 3-Way*, No Neutral Required

up to 40’ Self-Adjust or Manual

120 to 347V

32°F - 104°F (0°C - 40°C) / 20 to 90%, non-condensing W, V, LA, G, B

8 to 12’

Self-Adjust

15 sec to 30 min

24 VAC

Cafeteria High Ceiling

Vending Room

500

180°

10-30 VDC

GOOD

Restroom Residential

2MHO

0 sec to 30 min

Cafeteria

Restroom Non-Partitioned

1500

Self-Adjust

15 sec to 30 min

Included

180°

Self-Adjust or Manual

Applications

Residential Room

Passive Infrared Fixture

8 to 12’

Manual

Environmental Operating Temperature/Humidity

Closet/Utility

Passive Infrared

Yes

BAS/HVAC Relay

Feature

500

180° 4’

Voltage

Available Colors

Dual Technology Ceiling

720

Time Delay Switchpack/Power Pack Photocell

Ultrasonic

Wall Switch

NEMA WD 7 Standard Tested Pattern Mounting Height (ft.) Adjustment

Passive Infrared

GOOD

Stairwell

BEST

Vending Room GOOD

Warehouse Aisle Warehouse Open

Occupancy Sensor Application Guide Commercial Wall Switch Sensors

Commercial Line Voltage Fixture Mount

Commercial Line Voltage Ceiling Sensor

Commercial Low Voltage Wall/Corner Mount

OAWC-DT-120W

OAWC-P-009L-H

OAWC-P-120W

OEF-P-2MH0-MV-S

OAC-P-1500-DMV

OAC-P-1500-MV

OAC-P-0500-DMV

OAC-P-0500-MV

OXC-P-2MH0-R

OXC-P-1500-R

OAC-DT-2000

OAC-DT-1000

OAC-DT-0501

OAC-U-2000

OAC-U-1000

OAC-U-0501

OAC-P-1500

OAC-P-0500

VNLW-P-1001-MV-N-*

ONW-P-1001-RR7-*

ONW-P-1001-SP-*

ONW-P-1001-D347-*

ONW-P-1001-347-*

ONW-P-1001-DMV-*

ONW-P-1001-MV-*

ONW-D-1001-RR7-*

ONW-D-1001-SP-*

ONW-D-1001-DMV-N*

ONW-D-1001-MV-N-*

ONW-D-1001-MV-*

ONW-D-1001-DMV-*

Specification Grade OSW-U-0721-MV-*

OSW-P-0451-DMV-*

OSW-P-0451-MV-*

OSW-P-1001-MV-*

Commercial Grade

Commercial Low Voltage Ceiling Sensors

Specifications

Specifications Passive Infrared

Technology

Ultrasonic

Dual Technology

Mounting Coverage (sq. ft.)

1000

450

1000

1500

Manual

Self-Adjust

360°

500

1000

2000

500

1000

2000

120 or 277V

120 or 277V

120 or 277V

Not Required

15 sec to 2 hr

10-30 VDC

24 VAC

Required

RR7 Relay Required

Not Included

120 or 277V

347V

360°

1500

2MHO

360° up to 25’

Dual Technology Technology Wall/Corner Mount

Mounting

1200

90 Linear

1200

120°

180° 8 to 12’

120°

120 to 277V

10 to 30 VDC

Required

RR7 Relay Required

Not Required

Required

Not Required Included

Not Included

Included

Not Included

Included

Not Included

SP, True 3-Way, No Neutral Required

W, V, A

SP, 3-Way*, No Neutral Required

Dual Relay, 3-Way*, No Neutral Required

OAC-P0500-R

OAC-P-1500-R

OAC-U0501-R

OAC-U1000-R

OAC-U2000-R

OAC-DT0501-R

OAC-DT2000-R

SP, 3-Way*, Light Icon No Neutral

Dual Relay, 3-Way*, Light Icon, Fan Mode, No Neutral Required

SP, 3-Way*, Light Icon, EcoMeter

Dual Relay, 3-Way*, Light Icon, Fan Mode, EcoMeter

SP, Light Icon, EcoMeter

SP, 3-Way*, No Neutral Required, Light Icon, EcoMeter

Dual Relay, 3-Way*, No SP, 3-Way*, No Neutral Neutral, Light Required, Light Icon, EcoMeter Icon, EcoMeter

Dual Relay, 3-Way*, No Neutral Required, Light Icon, EcoMeter

SP, Light Icon, EcoMeter

SP, 3-Way*, Light Icon, EcoMeter Night Light

GOOD

BETTER

BEST

BEST

BEST

BEST

BETTER

BETTER

BETTER

BETTER

BETTER BETTER

GOOD

GOOD

Copy/File/Storage Room

BEST

BEST

BEST

BETTER

BEST

BEST

BEST

BEST

BEST

BEST

BEST

BEST

Commercial Line Voltage Ceiling Sensors BEST

GOOD

BEST

BEST

BETTER

BETTER

BETTER

BETTER

BETTER

BETTER

GOOD

GOOD

BEST

BEST

BEST

BEST

BEST

BEST

BEST

BEST

GOOD

GOOD

Hallway GOOD

GOOD

BETTER

BEST

BEST

BEST

BEST

Office Home Office Private Open Office w/Cubicles Parking Garage

GOOD GOOD

GOOD GOOD

GOOD GOOD

BETTER BETTER

BEST BEST

BEST BEST

BEST BEST

BEST BEST

BEST BEST

BEST

GOOD

GOOD

BEST

GOOD GOOD

GOOD GOOD

GOOD

GOOD

GOOD

GOOD

BETTER

BETTER

GOOD

GOOD

GOOD

BEST

BEST

BEST

Restroom Partitioned

BETTER

BEST

BEST

BEST

BEST

BEST

BEST

BETTER

BETTER

GOOD

GOOD

BEST

BEST

BEST

BEST

BEST

BEST

BETTER

BEST

BETTER

BEST

BETTER

BEST

GOOD

BEST

BEST BEST

BEST

BETTER

BETTER

BEST

BEST

BEST

GOOD

GOOD

GOOD

BEST

BEST

BEST

BEST

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

GOOD

Cafeteria Classroom

BETTER

BEST

Computer Room

GOOD

BETTER

BEST

Conference Room

BEST

BEST

GOOD

BETTER

Copy/File/Storage Room BETTER

Hallway

BEST

Loading Dock

BETTER

BETTER

BETTER

BEST

BEST

BEST

GOOD

GOOD

GOOD

GOOD

GOOD

BEST

GOOD

GOOD

BETTER

BETTER

BETTER

BEST

BEST

BEST

GOOD

GOOD

GOOD

GOOD

GOOD

BEST

BEST

BEST

BEST

BEST

BEST

BEST

Office Executive

BEST

BEST

Office Home Office Private Open Office w/Cubicles Parking Garage

BEST

BEST

Refrigerated Storage

BEST GOOD

Applications Cafeteria High Ceiling

GOOD GOOD

Feature

Closet/Utility

BEST

Residential Room GOOD

BETTER

BEST BEST

BEST

BEST

GOOD BEST

GOOD

Restroom Non-Partitioned

BEST

Restroom Partitioned

BEST

Restroom Residential GOOD

GOOD

GOOD

GOOD

BEST

BEST

BEST

BEST

GOOD BEST

BEST

Warehouse Aisles

BETTER

BETTER

Warehouse Open

BETTER

BETTER

3-Way*: Lights will turn OFF automatically when sensor that detected motion last times out. SP: Single Pole Colors: W-White; V-Ivory; LA-Light Almond; A-Almond; G-Gray; B-Black Other specialty sensors available at www.coopercontrols.com

Commercial Low Voltage Wall/Corner Mount

GOOD

BEST

BEST

Fixture Mount

GOOD

BETTER

Stairwell

Environmental Operating Temperature/Humidity

Up to 5 sensors can be used per Switchpack

GOOD

BEST

Refrigerated Storage BETTER

OAWC-DT-120W- Photocell R BAS/HVAC Relay

BEST

BEST GOOD

GOOD

BEST

Loading Dock Office Executive

OAWC-P-009LH-R

BEST

BEST

Computer Room Conference Room

No Switchpack Required

BEST BETTER

BEST

OAWC-P-120W-R

Available Colors

Commercial Low Voltage Ceiling Sensors

BEST

Switchpack/Power Pack

32°F to 104°F (0°C to 40°C) / 20% to 90%, non-condensing

Up to 5 sensors can be used per Switchpack

Classroom BEST

Not Included

Voltage

Required

W

BEST BEST

Included

Included

W, V, LA

Commercial Wall Switch Sensors

BEST

Not Included

NEMA WD 7 Standard Tested Pattern Mounting Height (ft.) Time Delay

10 to 30 VDC

Not Required OAC-DT1000-R

Coverage (sq. ft.)

Adjustment

120 to 277V

-40°F to 125°F (-40°C to 52°C) / less than 95%, non-condensing

W, V, LA, G, & B

SP 3-Way*, No Neutral Required

up to 40’ Self-Adjust or Manual

120 to 347V

32°F - 104°F (0°C - 40°C) / 20 to 90%, non-condensing W, V, LA, G, B

8 to 12’

Self-Adjust

15 sec to 30 min

24 VAC

Cafeteria High Ceiling

Vending Room

500

180°

10-30 VDC

GOOD

Restroom Residential

2MHO

0 sec to 30 min

Cafeteria

Restroom Non-Partitioned

1500

Self-Adjust

15 sec to 30 min

Included

180°

Self-Adjust or Manual

Applications

Residential Room

Passive Infrared Fixture

8 to 12’

Manual

Environmental Operating Temperature/Humidity

Closet/Utility

Passive Infrared

Yes

BAS/HVAC Relay

Feature

500

180° 4’

Voltage

Available Colors

Dual Technology Ceiling

720

Time Delay Switchpack/Power Pack Photocell

Ultrasonic

Wall Switch

NEMA WD 7 Standard Tested Pattern Mounting Height (ft.) Adjustment

Passive Infrared

GOOD

Stairwell

BEST

Vending Room GOOD

Warehouse Aisle Warehouse Open

Sensor Technologies Passive Infrared (PIR) Technology • •

Designed to detect motion from a heat-emitting source (such as a person entering a room) within its field-of-view and automatically switch lights ON and OFF. PIR sensors are considered line-of-sight sensors, meaning that the sensor must be able to have a direct line-of-light to the person making the motion.

Using this paper versus standard paper produced the following environmental benefits.

Based on Environmental Defense Fund Paper Calculator

Ultrasonic (US) Technology • • •

Ultrasonic sensors use the Doppler principle. These sensors produce low intensity, inaudible sound and detect changes in sound waves caused by motion. They are volumetric in nature and therefore not line-of-sight dependant. They are much more sensitive to smaller motions.

Dual Technology • • •

Dual Technology is the combination of PIR and Ultrasonic into one sensor and is the ultimate sensing solution available today. This pairing helps to eliminate false activations (both ON and OFF) thus saving additional energy use. Dual Technology sensors ensure the greatest sensitivity and coverage for tough applications without the threat of false triggers.

Number of Trees Saved

12

Total Energy Saved—Million BTU’s

7.9

Greenhouse Gas Reduction—lbs of CO2

4391

Gallons of Water Saved

4129

Solid Waste Reduction— lbs of Waste

683

Kilo-watt (kwh) Hours Saved

1702

MicroSet Self-Adjusting Technology • •

Continuously adjusts to conditions by adjusting sensitivity and Time Delay in real-time. By adjusting sensitivity and Time Delay automatically, the sensor is maximizing the potential energy savings that are available.

North America Headquarters 203 Cooper Circle Peachtree City, GA 30269 P: 800-553-3879 F: 800-954-7016

About Energy Codes

www.coopercontrol.com [email protected]

Cooper Controls Ltd Usk House, Lakeside, Llantarnam Park, Cwmbran, NP44 3HD. UK P: +44 (0)1923 495495 F: +44 (0)1923 867880

Canada 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: 905-507-4000 F: 905-568-7049

www.coopercontrol.com [email protected]

Energy costs and consumption continue to rise. Today, many energy codes and energy policies either require or incentivize the use of energy efficient lighting controls on commercial projects. ASHRAE 99.1-1999, 2001, 2004, 2007, 2010 In buildings over 5,000 square feet, all general lighting must be able to be automatically turned off. • Occupancy sensors can be used through out the building, in lieu of programmable timing, to meet the Automatic-Off requirement outlined in the ASHRAE standard. • In every building, regardless of size, ASHRAE requires that occupancy sensors be placed in classrooms, conference/meeting rooms, employee cafeterias and break rooms. As of December 30, 2010 The Department of Energy (DOE) recognizes the ASHRAE 2004 standard as the new national minimum.

LEED Green Building Rating System Both of the above ASHRAE requirements must be met by any project hoping to earn LEED certification. Lighting controls can contribute toward meeting a prerequisite and earning up to 24 percent or 24 of the 100 points available in LEED 2009. • Use occupancy sensors to earn LEED points by significantly improving the energy performance of the building.

Version 3.0

California Title 24 Automatic shut-off occupancy sensors must be installed in the following areas to turn off the lighting when a space is unoccupied: • • • •

Offices 250 sq. ft. or smaller Multipurpose rooms of less than 1000 sq. ft. Classrooms of any size Conference rooms of any size

Space Control - Requires individual control devices in spaces enclosed with floor to ceiling height partitions and include individual rooms for partitioned open offices. Light level reduction control - Requires simple switching strategies to reduce light levels by up to 50%. Bi-level occupancy sensors can also meet the requirements by offering 2 levels of control.

IECC • ASHRAE and Title 24 requirements must be met. • IECC 2003 & 2006, Occupants must be able to reduce lighting load in the space in a reasonably uniform pattern by at least 50%. Bi-Level occupancy sensors offering personal control can be used to comply with this mandatory requirement.

Cooper US, Inc. 600 Travis, Suite 5600 Houston, TX 77002 P: 713-209-8400 F: 713-209-8995 www.cooperindustries.com

ACC120033

Cooper Controls, Greengate, Novitas, PCI Lighting Control Systems, VisionTouch, VisionSwitch, MicroSet, Digita, ControlKeeper, LiteKeeper, IntelliRelay, NeoSwitch, TracKeeper, Revio, and Ineo are valuable trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to use Cooper Trademarks without the prior written consent of Cooper Industries.

Printed in USA

Greengate Occupancy Sensor Guide

Sensor Technologies Passive Infrared (PIR) Technology • •

Designed to detect motion from a heat-emitting source (such as a person entering a room) within its field-of-view and automatically switch lights ON and OFF. PIR sensors are considered line-of-sight sensors, meaning that the sensor must be able to have a direct line-of-light to the person making the motion.

Using this paper versus standard paper produced the following environmental benefits.

Based on Environmental Defense Fund Paper Calculator

Ultrasonic (US) Technology • • •

Ultrasonic sensors use the Doppler principle. These sensors produce low intensity, inaudible sound and detect changes in sound waves caused by motion. They are volumetric in nature and therefore not line-of-sight dependant. They are much more sensitive to smaller motions.

Dual Technology • • •

Dual Technology is the combination of PIR and Ultrasonic into one sensor and is the ultimate sensing solution available today. This pairing helps to eliminate false activations (both ON and OFF) thus saving additional energy use. Dual Technology sensors ensure the greatest sensitivity and coverage for tough applications without the threat of false triggers.

Number of Trees Saved

12

Total Energy Saved—Million BTU’s

7.9

Greenhouse Gas Reduction—lbs of CO2

4391

Gallons of Water Saved

4129

Solid Waste Reduction— lbs of Waste

683

Kilo-watt (kwh) Hours Saved

1702

MicroSet Self-Adjusting Technology • •

Continuously adjusts to conditions by adjusting sensitivity and Time Delay in real-time. By adjusting sensitivity and Time Delay automatically, the sensor is maximizing the potential energy savings that are available.

North America Headquarters 203 Cooper Circle Peachtree City, GA 30269 P: 800-553-3879 F: 800-954-7016

About Energy Codes

www.coopercontrol.com [email protected]

Cooper Controls Ltd Usk House, Lakeside, Llantarnam Park, Cwmbran, NP44 3HD. UK P: +44 (0)1923 495495 F: +44 (0)1923 867880

Canada 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: 905-507-4000 F: 905-568-7049

www.coopercontrol.com [email protected]

Energy costs and consumption continue to rise. Today, many energy codes and energy policies either require or incentivize the use of energy efficient lighting controls on commercial projects. ASHRAE 99.1-1999, 2001, 2004, 2007, 2010 In buildings over 5,000 square feet, all general lighting must be able to be automatically turned off. • Occupancy sensors can be used through out the building, in lieu of programmable timing, to meet the Automatic-Off requirement outlined in the ASHRAE standard. • In every building, regardless of size, ASHRAE requires that occupancy sensors be placed in classrooms, conference/meeting rooms, employee cafeterias and break rooms. As of December 30, 2010 The Department of Energy (DOE) recognizes the ASHRAE 2004 standard as the new national minimum.

LEED Green Building Rating System Both of the above ASHRAE requirements must be met by any project hoping to earn LEED certification. Lighting controls can contribute toward meeting a prerequisite and earning up to 24 percent or 24 of the 100 points available in LEED 2009. • Use occupancy sensors to earn LEED points by significantly improving the energy performance of the building.

Version 3.0

California Title 24 Automatic shut-off occupancy sensors must be installed in the following areas to turn off the lighting when a space is unoccupied: • • • •

Offices 250 sq. ft. or smaller Multipurpose rooms of less than 1000 sq. ft. Classrooms of any size Conference rooms of any size

Space Control - Requires individual control devices in spaces enclosed with floor to ceiling height partitions and include individual rooms for partitioned open offices. Light level reduction control - Requires simple switching strategies to reduce light levels by up to 50%. Bi-level occupancy sensors can also meet the requirements by offering 2 levels of control.

IECC • ASHRAE and Title 24 requirements must be met. • IECC 2003 & 2006, Occupants must be able to reduce lighting load in the space in a reasonably uniform pattern by at least 50%. Bi-Level occupancy sensors offering personal control can be used to comply with this mandatory requirement.

Cooper US, Inc. 600 Travis, Suite 5600 Houston, TX 77002 P: 713-209-8400 F: 713-209-8995 www.cooperindustries.com

ACC120033

Cooper Controls, Greengate, Novitas, PCI Lighting Control Systems, VisionTouch, VisionSwitch, MicroSet, Digita, ControlKeeper, LiteKeeper, IntelliRelay, NeoSwitch, TracKeeper, Revio, and Ineo are valuable trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to use Cooper Trademarks without the prior written consent of Cooper Industries.

Printed in USA