HEARTFELT GUESTHOUSE

CAST IN PLACE CONCRETE BEAM. CONCRETE TO BE MINIMUM OF 3000 PSI WITH BROOM FINISH.

ATTACHMENT AD1-L3

1/4" R. @ REMOVE ALL TROWEL MARKS PLANT BED

6"

GEOTEXTILE FABRIC C.S.I. GEO SYNTHETIC 4 oz. WOVEN FABRIC OR EQUAL. OVERLAP SEAMS 18" MINIMUM.

9"

1'-0"

(2) #4 BAR CONTINUOUS MINIMUM CLEARANCE OF 2" LAP SPLICE MIN. 14"

12" "REXIUS" ENGINEERED WOOD CHIPS FOR PLAYGROUNDS.

03/02/2018 ADDENDUM #1 REFFERENCE L6.0 OF PERMIT SET

4" SUBBASE 3/4" MINUS CRUSHED ROCK, COMPACTED

9" OF 3/4" OPEN ROUND ROCK

UNDISTURBED OR COMPACTED SUBGRADE

NOTE: PLAY STRUCTURE FOOTING LOCATION AND SIZE AS PER MANUFACTURER SPECIFICATION

4" FLEX PERFORATED PIPE. SET UNDER GEOTEXTILE FABRIC. SEE GRADING PLAN FOR LOCATION AND CONNECTION TO STORM WATER SYSTEM

6'-0" MAINTENANCE STRIP @ PLAYGROUND

1:12 MAX.

GEOTEXTILE FABRIC C.S.I. GEO SYNTHETIC 4 oz. WOVEN FABRIC OR EQUAL. OVERLAP SEAMS 18" MINIMUM. HOLD ENDS 2" BELOW FINISH SURFACE.

2" CLEAR, TYP.

6"

6"

12"

12" "REXIUS" ENGINEERED WOOD CHIPS FOR PLAYGROUNDS. COVER CONCRETE RAMP

CONCRETE PAVING

CONCRETE RAMP BELOW WOOD CHIPS : CAST IN PLACE CONCRETE WITH #4 BAR 16" O.C. BOTH DIRECTIONS, CONCRETE TO BE A MINIMUM OF 3000 PSI BROOM FINISH ACROSS WIDTH OF SLOPE. A CONTINUOUS BAR MUST MAKE UP CORNERS.

6" OF 3/4" OPEN ROUND ROCK

REBAR 16" LONG - #4 BAR @ 24" O.C. MINIMUM 2" CLEAR. COMPACTED OR UNDISTURBED SUBGRADE SLOPE AT 2% MINIMUM TO PERF PIPE.

6

MINIMUM 4" OF 3/4" MINUS COMPACTED CRUSHED QUARRY ROCK, COMPACTED TO AT LEAST 95% OF THE MATERIAL'S MAXIMUM DRY DENSITY AS DETERMINED BY AASHTO METHOD T-99

PLAY EQUIPMENT ACCESS, MAINTENANCE STRIP AND RAMP SCALE: 3/4" = 1' - 0"