INDECON SOLID

Report 2 Downloads 191 Views
Indecon Solid 1, 2, 3-Lamp T8, Indirect Distribution Project Information Project Name

Type

Catalog No.

Date

Construction The Indecon series is constructed of heavy 20 gauge steel with a 9 9 ⁄16" × 3⅛" profile. Fixtures are available with one, two or three T8 lamps. A unique angling method on the one lamp unit and on the middle lamp of the three lamp unit minimizes the length of the fixture without affecting the performance or operation of the unit. This lamp positioning ensures that all fixtures are made in four foot increments. The exact shape of the housing is maintained by the use of an inner structural plate at each socket location. The plate is tabbed and welded into the housing, ensuring housing tolerances are consistent. Aligner fingers are standard on the plate enabling fixtures to be attached together in straight continuous rows without misalignment between fixtures. End caps are made of 18-gauge construction and attach with nuts and bolts. The reflector is constructed of specular anodized aluminum for wide distribution with maximum efficiency.

Features • A gently pointed shape enhances this curved profile • Primarily indirect, Indecon is well-suited to office, education, and health care where uplight is desired as the primary source • T8 lamps • Heavy 20-gauge steel construction provides excellent housing rigidity • 3⅛" deep housing is gently angled for visual interest • Solid housing offers 100% indirect light • Perforated housing option allows +/- 5% downlight • All perforated housing provides a continuous glow across the width of the unit for approximately 10% downlight • Fixed 18" (FCM18) or optional Adjustable 48" (CM48) aircraft cable suspension mountings available • Finger tab connections for quick and easy alignment • Modular mounting points for predictable hanging locations • UL Listed 1598

Finish The housing and all painted parts are treated with a five stage phosphate bonding process before being finished. Parts are then finished with a white RAL powder coat finish for maximum consistent coverage and longevity.

Shape and Dimensions

Mounting The Indecon is designed for ceiling suspension and is provided with a aircraft cable suspension mechanism. The cable has a total vertical adjustment of 1¼". End of cable barrel screws into a standard ¼-20 bolt brought down from the ceiling. Cover plates are provided to shield the ceiling cutout. A straight or optional coil cord is provided for feed locations. A feed canopy is provided for each feed location. All fixtures are suspended at 48" increments and must be supported at each fixture housing end. Refer to the Indecon TID sheet for actual hanging points for specific rows. Labels and Electrical UL listed 1598. cUL or CSA. Damp location listed.

Name: Test #: Efficiency: LER:

IDCL-2T8-S-E-WR 12586 74.5% 84

3⅛" 9⁹⁄₁₆"

Ordering Information

IDC



Model IDC Indecon

— LAMP TYPE AND PROFILE 1T8 One T8 Lamp 2T8 Two T8 Lamps 3T8 Three T8 Lamps

Row length 4' Single 8' Single 12' Single Indicate row length over 12' in 4' increments Note: Rows over 12' will be configured by Alera. Example: 16' will be (2) 8'. Alternate configurations: contact factory. 4 8 12 —

Example: IDC-8-2T8-S-CM48-EU-MW



S





MOUNTING FCM Fixed Cable Mount (Non-adjustable, Std.) CM Adjustable Aircraft Cable Mount

Housing type S Solid

Adjustable cable length 48 48" 96 96" Other lengths available on request.

Specify voltage. For additional, specify quantity before nomenclature (Example: 2EL120). Not available with all configurations; some limitations apply. Contact factory for details. One extra feed drop per EMC/NLC. For through wiring, contact factory.

1 2 3

— U 120 277 347

Voltage 120V-277V 120V 277V 347V

Ballast E Electronic, Instant Start, (Std. for T8) EP Electronic, Programmed Start (Optional for T8) ED Electronic, Dimming (Must specify) Unless specified, Alera will use fewest ballasts possible.

— Finish MW Matte White (Std.) ZT ZET Metallic Silver See Color Selection Guide for other colors.

DC WR HRF LR IBOB EL EMC NLC GLR GMF TBAR

Options Dust Cover (N/A T5HO) White Reflector High Efficiency Reflector Left/Right Switching (2-Lamp only) Inboard/Outboard Switching (3-Lamp only) One Emergency Battery Pack1, 2 One Emergency Circuit2, 3 Night Light Circuit2, 3 Fast Blow Fuse Slow Blow Fuse T-Bar Mounting

Page 1/3 Rev. 06/26/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Curves / IDC SOLID

Indecon Solid 1, 2, 3-Lamp T8, Indirect Distribution Cross section

3⅛"

3⅛"

3⅛"

9⁹/₁₆"

9⁹/₁₆"

9⁹/₁₆"

One Lamp

Two Lamp

Three Lamp

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

IDC-1T8-S-E Indecon Architectural Curve 9.5" × 48" 1-Lamp with Specular Reflector B132I120HP 0.88 F32T8 2900 30 Pendant 0º = 90  90º = 90 0º = 0.00  90º = 0.00 Length: 4.00 Width: 0.67 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 90.0 97.5 105.0 112.5 120.0 127.5 135.0 142.5 150.0 157.5 165.0 172.5 180.0

0.0 22.5 45.0 67.5 90.0

0 22 57 101 145 189 229 264 293 316 334 344 346

0 0 0 0 214 197 185 190 282 541 570 570 262 617 795 841 274 554 802 871 296 478 691 772 319 454 583 640 336 442 525 560 347 426 487 510 353 406 447 461 353 384 406 414 350 361 369 372 346 346 346 346

Zonal Lumen Summary Zone

90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 1093 1544 2160 2489 2489

37.7 53.3 74.5 85.8 85.9

43.9 62.0 86.8 100.0 100.0

RCR

Luminaire

Angle

Luminaire Data Test 12193

RC RW 1 2 3 4 5 6 7 8 9 10

70 74 68 62 56 51 47 43 40 37 34

80 50 30 71 68 62 57 54 49 48 42 42 36 38 31 34 27 30 24 27 21 25 19

10 65 53 44 37 31 27 23 20 17 15

70 63 58 52 48 44 40 37 34 31 29

70 50 30 61 58 53 49 46 42 41 36 36 31 32 27 29 24 26 21 23 19 21 17

10 56 46 38 32 27 23 20 17 15 13

50 41 36 32 28 25 22 20 18 16 15

50 30 40 34 29 25 22 19 17 15 13 12

10 39 32 27 23 19 16 14 12 11 9

0 0 0 0 0 0 0 0 0 0 0 0

Indoor Candela Plot 150 135 180 165 900 120 450 105 90 75

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

450 60

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Comparative Yearly Lighting Energy Cost per 1000 Lumens

85.8% 73 $3.29 based on 3000 hrs. and $0.08 per KWH

900 0 15 30 Horiz 0-180 0.0 90.0 45.0

45

Test Date 8/20/98

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

IDC-2T8-S-E Indecon Architectural Curve 9.5" × 48" 2-Lamp with Specular Reflector B232I120RH 0.88 F32T8 2900 56 Pendant 0º = 90  90º = 90 0º = 0.00  90º = 0.00 Length: 4.00 Width: 0.67 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 90.0 97.5 105.0 112.5 120.0 127.5 135.0 142.5 150.0 157.5 165.0 172.5 180.0

0.0 22.5 45.0 67.5 90.0

0 53 130 224 320 415 506 583 650 703 742 766 775

0 276 478 634 753 823 850 849 836 816 794 781 775

0 319 693 904 1019 1135 1195 1202 1127 1018 904 813 775

0 332 713 1062 1205 1277 1367 1369 1310 1163 986 834 775

0 340 720 1103 1253 1318 1409 1415 1362 1206 1014 839 775

Zonal Lumen Summary Zone

90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 1655 2550 4079 4881 4881

28.5 44.0 70.3 84.2 84.2

33.9 52.2 83.6 100.0 100.0

RCR

Luminaire

Angle

Luminaire Data Test 12154

RC RW 1 2 3 4 5 6 7 8 9 10

70 73 66 60 55 50 46 42 39 36 34

80 50 30 70 66 61 56 53 48 47 41 41 35 37 31 33 27 30 24 27 21 24 19

10 64 52 43 36 31 26 23 20 17 15

70 62 56 51 47 43 39 36 33 31 29

70 50 30 59 57 52 48 46 41 40 35 36 30 32 27 28 23 25 20 23 18 21 16

10 55 45 37 31 27 23 20 17 15 13

50 41 36 31 28 25 22 20 18 16 15

50 30 39 33 29 25 21 19 16 14 13 11

10 38 31 26 22 19 16 14 12 11 9

0 0 0 0 0 0 0 0 0 0 0 0

Indoor Candela Plot 150 135 180 165 1500 120 750 105 90 75

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

750 60

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Comparative Yearly Lighting Energy Cost per 1000 Lumens

84.2% 77 $3.12 based on 3000 hrs. and $0.08 per KWH

1500 0 0.0

15 30 Horiz 0-180 90.0 45.0

45

Test Date 7/20/98 Page 2/3 Rev. 06/26/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Curves / IDC SOLID

Indecon Solid 1, 2, 3-Lamp T8, Indirect Distribution Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

IDC-3T8-S-3E Indecon Architectural Curve 9.5" × 48" 3-Lamp with Specular Reflector B332I120RH 0.88 F32T8 2900 83 Pendant 0º = 90  90º = 90 0º = 0.00  90º = 0.00 Length: 4.00 Width: 0.67 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 90.0 97.5 105.0 112.5 120.0 127.5 135.0 142.5 150.0 157.5 165.0 172.5 180.0

0.0 22.5 45.0 67.5 90.0

0 139 283 429 575 716 846 961 1056 1134 1192 1226 1240

0 312 686 948 1119 1228 1281 1305 1303 1290 1269 1251 1240

0 314 789 1220 1525 1711 1799 1806 1710 1574 1427 1303 1240

0 318 786 1274 1679 1931 2083 2083 1995 1787 1551 1341 1240

0 325 788 1284 1702 1983 2147 2156 2070 1850 1588 1349 1240

Zonal Lumen Summary Zone

90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 2103 3443 5777 7031 7031

24.2 39.6 66.4 80.8 80.8

29.9 49.0 82.2 100.0 100.0

RCR

Luminaire

Angle

Luminaire Data Test 12171

RC RW 1 2 3 4 5 6 7 8 9 10

70 70 64 58 53 48 44 41 38 35 32

80 50 30 67 64 58 54 51 46 45 39 40 34 35 29 32 26 28 23 26 20 23 18

10 61 50 41 35 29 25 22 19 16 14

70 60 54 49 45 41 38 35 32 30 27

70 50 30 57 55 50 46 44 39 39 34 34 29 30 25 27 22 24 20 22 17 20 16

10 53 43 36 30 26 22 19 16 14 13

50 39 34 30 27 24 21 19 17 15 14

50 30 38 32 27 24 20 18 16 14 12 11

10 36 30 25 21 18 15 13 12 10 9

Indoor Candela Plot 0 0 0 0 0 0 0 0 0 0 0 0

180 165 2200

150

120 1100 105 90 75

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

1100 60

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Comparative Yearly Lighting Energy Cost per 1000 Lumens

135

80.8% 75 $3.20 based on 3000 hrs. and $0.08 per KWH

2200 0 0.0

15 30 Horiz 0-180 90.0 45.0

45

Test Date 8/4/98

Page 3/3 Rev. 06/26/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Curves / IDC SOLID