The FA Series line of gas-fired, tubular exchanger, induced draft hot air heaters are now available for use in commercial, industrial & agricultural applications. This line of heaters features a low profile design with a durable, powder-coated black enamel exterior and stainless steel louvers for an exceptional aesthetic appeal. Additional features include operational troubleshooting lights, swept-wing impeller with fingerproof fan guards for low noise operation and various mounting options. The FA Series can be used as separated combustion or power-vented out-of-the-box.

btu/h INPUT OUTPUT

Typical Mounting Height

Approx. AvERaGE Heat air Temp vent length Ship Throw Rise Min. Max. weight

MODEL Number

Gas Type

FA-100

Nat. or LP

100,000

80,000

12 to 14 Ft.

43 Ft.

50°F

3 Ft.

40 Ft.

143 Lbs.

FA-125

Nat. or LP

125,000 100,000

14 to 16 Ft.

57 Ft.

50°F

3 Ft.

40 Ft.

143 Lbs.

FA-150

Nat. or LP

150,000 120,000

14 to 16 Ft.

52 Ft.

50°F

3 Ft.

40 Ft.

195 Lbs.

FA-175

Nat. or LP

175,000 140,000

15 to 17 Ft.

51 Ft.

50°F

3 Ft.

40 Ft.

195 Lbs.

FA-200

Nat. or LP

200,000 160,000

15 to 17 Ft.

55 Ft.

50°F

3 Ft.

40 Ft.

195 Lbs.

FA-225

Nat. or LP

225,000 180,000

16 to 18 Ft.

59 Ft.

50°F

3 Ft.

40 Ft.

212 Lbs.

FA-250

Nat. or LP

250,000 200,000

16 to 18 Ft.

63 Ft.

50°F

3 Ft.

40 Ft.

212 Lbs.

TYPICAL APPLICATIONS

PRODUCT FEATURES Operational Indicator Lights

Swept-wing Fan Blade

• Greenhouses Stainless Steel Discharge Louvers Powder Coated Black Enamel Exterior

Aluminized Steel Tubular Heat Exchangers

• Warehouse Spaces • Service Garages • Entrance Ways • Manufacturing Facilities

Burner Sight Glass

detroit radiant products co.

• Compact, aesthetically pleasing construction. • Easy to install with minimal assembly required. • Swept wing air propeller, for noise reduction. • Indicator lights are standard. • Finger proof fan guards are standard. • Models through 125 MBH can be rotated 180˚. • ETL Listed North American Certified for indoor use.

21400 Hoover Rd. Warren, MI 48089-3162 Phone: Toll Free: Fax: Email: Website:

(586) 756-0950 1-800-222-1100 (586) 756-2626 [email protected] www.detroitradiant.com

Visit Our Website For: Product Specs Parts Support Dealer Locator Applications

C.A.D. Library Design Guidelines Theory of Infrared and More!

FA SERIES

SPECIFICATIONS PRODUCT SPECIFICATIONS

VOLTAGE:

Input Range:

100,000 to 250,000 BTU/h

Gas Type:

Natural or Propane

Burner Control Box:

Powder coated black enamel

Radiant Exchanger Tubes:

Tubular aluminized steel

Certification:

ETL Listed North America

Limited Warranty:

1-3-5 (Components-ExchangersThermostat Connection

Operational Indicator Lights:

Standard

• Non-reversible horizontal mounting. •Mounting with (4x) -3/8”-16 threaded inserts.

MANIFOLD PRESSURE:

• Natural Gas - 3.5 Inches W.C. CERTIFICATIONS: • Propane Gas - 10.0 Inches W.C. • ANSI Z83.8/CSA 2.6 • Commercial & Industrial use. INLET PRESSURE: • Indoor use only. • Natural Gas - 5.0 to 14.0” W.C. OTHER • Propane Gas - 11.0 to •External indicator lights. 14.0” W.C. • External thermostatic connection. GAS CONNECTION • Approved for elevations • FA-100-200: 1/2” N.P.T. 0 - 2,000 ft. without • FA-225-250: 3/4” N.P.T. modifications. • Field connect to valve. • Supplied standard as separated combustion.

Burners) 24V Controls:

MOUNTING:

• 120/60Hz. VAC (primary). • 24 VAC (thermostatic). • Single phase.

VENT & INLET CONNECTION: • Category l or lll venting. • Rear, horizontal discharge/inlet.

Available fa SERIES models & dimensions Model

FLA AMPS

Motor Type

MoTor HP

Fan DiaMeter

Axial Fan Rotation

Gas Connection

Inlet & Vent Connection

heater height dim “A“

air to vent dim “B”

mounts axis dim “C”

mounts axis dim “D”

FA-100

5.2

PSC

1/8

18 in.

CCW

1/2” NPT

4” O.D.

21 in.

9.375 in.

9.5 in.

19.125 in.

FA-125

5.0

PSC

1/6

18 in.

CCW

1/2” NPT

4” O.D.

21 in.

9.375 in.

9.5 in.

19.125 in.

FA-150

10.7

PSC

1/3

22 in.

CCW

1/2” NPT

6” O.D.

27 in.

12.5 in.

9.5 in.

19.125 in.

FA-175

10.7

PSC

1/3

22 in.

CCW

1/2” NPT

6” O.D.

27 in.

12.5 in.

9.5 in.

19.125 in.

FA-200

10.7

PSC

1/3

22 in.

CCW

1/2” NPT

6” O.D.

27 in.

12.5 in.

9.5 in.

19.125 in.

FA-225

10.7

PSC

1/3

22 in.

CCW

3/4” NPT

6” O.D.

30 in.

13.875 in.

9.5 in.

19.125 in.

FA-250

10.7

PSC

1/3

22 in.

CCW

3/4” NPT

6” O.D.

30 in.

13.875 in.

9.5 in.

19.125 in

13.10”

40”

4.10”

DIM.C

20”

DIM. D 40”

fa SERIES clearances All Models

front

DIM. A

Rear View

Top View

DIM. B

9.3”

4.84”

Top and Bottom

8.6”

6.12”

Access Side

Non-Access Side

Rear

Vent Connection

Clearance to Combustibles

60 in

1 in.

18 in.

1 in.

1 in.

6 in.

Clearance to Allow Service

60 in.

1 in.

18 in.

1 in.

18 in.

6 in.

Top

Top

FRONT VIEW

SIDE VIEW Front

NonAccess Side

Access Side

Bottom

Rear

DISTRIBUTED BY:

Bottom

LBFA-FA 11/13 DRP