INSTALLATION (57M90

REPLACEMENT HEAT EXCHANGER KIT

504,767M 6/2003

Dallas, Texas, USA

INSTRUCTIONS

THROUGH

57M99)

FOR REPLACEMENT USED WITH

G51MP

HEAT EXCHANGER & G61MP

SERIES

KITS

UNITS

A,WARNING

Package 1 of I contains the following: 1 - Heat exchanger assembly

Check equipment for shipping damage. ]f damage is found, immediately contact last carrier.

A, CAUTION See table 1 for unit model numbers and corresponding replacement heat exchanger kits. TABLE 1 Unit Model Number

Kit Number

Catalog Number

LBq01518G

57M90

1 - Turn off electrical and gas supplies to the furnace.

LB-101518J

57M92

2 - Remove the upper and lower fumace access panels.

LB-101518K

57M93

3 - Mark all gas valve wires and disconnect them from valve

LB*101518L

57M94

G51MP-60D_135

LBq01518M

57M95

G61 MP-36B-045

LB-101518N

57M96

G61 MP-36B-070

LBq01518P

57M97

G61MP-48Cq G61MP*60Cq

LB-101518R

57M98

LBq01518S

57M99

G51 MP-24B-045 G51 MP*36B-045 G51 MP-36B-070 G51/61 MP-48C_090 G51/61MP-60C-090 G51MP-48Cq G51MP*60Cq

10 10

10 10

G61MP-60D_135

Refer to figure 1 or figure 2 when disassembling unit.

4-

Remove gas supply line connected to gas valve. Remove gas valve/manifold assembly.

5 - Remove sensor wire from sensor. Disconnect 2-pin plug from the ignitor. 6 - Disconnect wires from flame roll-out switches. 7 - Disconnect air intake piping from burner box. NOTE - It may be necessary to cut air intake pipe. 8 - Remove burner box cover and remove four burner box screws at the vestibule panel and remove burner box. Set burner box assembly aside. NOTE - G61MP-135 units are secured to the vestibule panel by two additional screws which are required to secure the assembly during shipping. These screws must be removed for servicing; however it is not necessary to replace these screws.

ELECTROSTATIC DISCHARGE (ESD) Precautions and Procedures

I

_

CAUTION

9 - Loosen three clamps and remove flexible exhaust tee. 10 - Remove 3/8 inch rubber cap from condensate drain plug and drain. Replace cap after draining. 11 - Disconnect condensate drain line from the condensate trap. Remove condensate trap (it may be necessary to cut drain pipe). Remove screws that secure condensate collars to either side of the furnace and remove collars. Remove drain tubes from cold end header collector box. 504,767M

06/03

IIIIIIIIIIIIIIIIIIIIIIltlllIIIIIltllllll

Page1

IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII

12- Disconnect condensate draintubingfromfluecollar. Removescrewsthatsecurebothflue collarsinto place.Removefluecollars.It maybenecessaryto cuttheexitingexhaustpipeforremovalofthefittings. 13- Markanddisconnectall combustionair pressure tubingfromcold endheadercollectorbox.Keep tubingattachedtopressureswitches. 14- Markand removewiresfrom pressureswitches, Removepressure switches. Keeptubingattached to pressureswitches. 15-Disconnectthe 2-pin or 3-pin plug from the combustion airinducer.Disconnect thetwowiresto the back-upsecondarylimit,if applicable. Remove fourscrewswhichsecurecombustion airinducerto collector box Removecombustionair inducer assembly. Removegroundwirefromvestpanel. 16- Removeelectricaljunctionboxfromthesideofthe furnace. 17- Markanddisconnect anyremaining wiringtoheating compartment components. Disengagestrainrelief bushingandpullwiringandbushing throughthehole intheblowerdeck, 18- Removetheprimarylimitfromthevestibulepanel. 19- Removetwoscrewsfromthefrontcabinetflangeat the blowerdeck.Spreadcabinetsidesslightlyto allowclearance forremovalof heatexchanger. 20- Removescrewsalongvestibulesidesandbottom whichsecurevestibulepanelandheatexchanger assemblyto cabinet,Removetwo screwsfrom blowerrailwhich securebottomheatexchanger flange. Removeheat exchangerfrom furnace cabinet. 21-Install replacement heat exchangerinto cabinet, makingsure that clamshellsof heat exchanger assemblyare restingonthe supportlocatedat the rearofthecabinet. Remove theindoorblowertoview thisareathroughthe bloweropening. 22- Re-secure thesupporting screwsalongthevestibule sidesandbottomtothecabinet.

29- Carefullyconnectcombustionairpressureswitch hosingfrompressureswitchestoproperstubson coldendheadercollectorbox.

,&WARNING

30 - Reinstall condensate

collars on each side of the

furnace, Reconnect drain tubing to collector box. 31 - Reinstall condensate trap, Reconnect condensate drain line to the condensate trap. 32 - Use securing screws to reinstall flue collars to either side of the furnace, Reconnect exhaust piping and exhaust drain tubing. 33-Replace flexible exhaust tee on combustion air inducer and flue collars. Secure using three existing hose clamps. 34 - Reinstall burner box assembly in vestibule area. Reconnect sensor wire and reconnect 2-pin plug from ignitor. 35 - Reconnect flame roll-out switch wires. 36 - Secure burner box assembly to vestibule panel using four existing screws. Make sure burners line up in center of burner ports. NOTE - It is not necessary to reinstafl two additional screws on -!35 models. These screws are necessary shipping.

only

to secure

the assembly

during

37 - Reinstall air intake piping, 38 - Reinstall gas valve manifold assembly. Reconnect gas supply line to gas valve. Use a leak detecting solution or other preferred means to check gas connections for leaks,

,A CAUTION

23- Reinstallcabinetscrewsonfrontflangeat blower deck. 24- Reinstalltheprimarylimitonthevestibulepanel, 25- Routeheatingcomponentwiringthroughholein blowerdeckandreinsertstrainreliefbushing, 26- Reinstallelectrical junctionbox. 27- Reinstallthecombustion airinducer.Reconnect the 2-pinor 3-pinplugto thewireharness.Reconnect the two wiresto the back-upsecondarylimit, if applicable, 28- Reinstallpressureswitches andreconnect pressure switchwiring.

39 - Reinstall bumer box cover. 40 - Reconnect wires to gas valve. 41 - Replace the blower compartment access panel. 42 - Refer to instruction on verifying gas and electrical connections when re-establishing supplies. 43-Follow lighting instructions to light and operate furnace for 5 minutes to ensure that heat exchanger is clean and dry and that furnace is operating properly. 44 - Replace heating compartment access panel.

Page 2

G51MP

PARTS

SHIPPING SCREWS (-135 only)

IDENTIFICATION

DuraIokPIus TM HEAT EXCHANGER ASSEMBLY

BURNER BOX ASSEMBLY

GAS VALVE AND MANIFOLD

FLUE COLLAR

COMBUSTION AIR PRESSURE PROVE SWITCHES

WARM HEADER (COLLECTOR) BOX

COMBUSTION AIR'*'_ INDUCER CONDENSER BURNER ACCESS PANEL

PRIMARY LIMIT

/_, _ _, / _ BLOWER ACCESS DOOR

COLD HEADER (COLLECTOR) BOX

DOOR INTERLOCK SWITCH

Cb

SECONDARY LIMITS (2)

\

BLOWER ASSEMBLY

SIGHT GLASS CONTROL BOX

FIGURE 1

Page 3

COIL

G61MP

SHIPPING

PARTS

IDENTIFICATION

DuraIokPlus TM HEAT EXCHANGER ASSEMBLY

SCREWS

(-135 only)

BURNER BOX ASSEMBLY

GAS VALVE AND MANIFOLD

FLUE COLLAR

COMBUSTION AIR PRESSURE PROVE SWITCHES* COMBUSTION INDUCER

WARM HEADER (COLLECTOR) BOX AIR CONDENSER

BURNER ACCESS PANEL

PRIMARY LIMIT

COLD HEADER (COLLECTOR) BOX BLOWER ACCESS DOOR

-.....

DOOR INTERLOCK SWITCH

SECONDARY LIMITS (2)

\ *G61MP=090 shown. G61MP4145and=070 are equtpped with two sw_ches.

BLOWER ASSEMBLY

SIGHT GLASS CONTROL BOX

FIGURE 2

Page 4

COIL