Pump Control Panels-3 Phase Duplex

Report 6 Downloads 63 Views
Float Switch Operated (Empty Tank)

Pump Control Panels-3 Phase Duplex 6

1

H1

H2

2

H3

Features

7

Check It

H4

MPS 1

MPS 2

8

TM

X2

N/A

XF

X1

4

1 4

Thermoplastic for NEMA 1/4X

5 2

3

Control Power

L1 L2 L3

Line Source 208 VAC 230 VAC 460 VAC

Stop

Lead

Lag

Alarm Pump #1

Pump #2

Alarm Indicator

Top mounted beacon (NEMA 4X) Door mounted indicator (NEMA 1)

Pump Connections

Auxiliary Contacts

3

Enclosure

T1 T2 T3 T1 T2 T3

3

Alarm Buzzer

Loud 100 db warble

Base Model

Panel Options

4

Test alarm system

THREE PHASE DUPLEX 5

1.0- 1.6 FLA 1.6- 2.5 FLA 2.5- 4.0 FLA 4.0- 6.3 FLA 6.0-10.0 FLA 9.0- 14.0 FLA 13.0- 18.0 FLA 17.0- 23.0 FLA 20.0- 25.0 FLA 24.0- 32.0 FLA 30.0- 40.0 FLA 37.0- 50.0 FLA 48.0- 65.0 FLA

208/230/460 VAC 208/230/460 VAC 208/230/460 VAC 208/230/460 VAC 208/230/460 VAC 208/230/460 VAC 208/230/460 VAC 208/230/460 VAC 208/230/460 VAC 208/230/460 VAC 208/230/460 VAC 208/230/460 VAC 208/230/460 VAC

OPTION CODES A Event counter B Elapsed time meter C Auxiliary alarm contacts* Standard feature on Check It Panel D Lockable latch E Alarm flasher F1 Lighting protection - Single Phase G 4th float, seperates lag from alarm I Redundant off float L Pump run auxiliary contacts (i.e. chemical feed). L1 Pump run indicator - door mounted L2 HOA & pump run indicator - door mounted L3 TOA & pump run indicator - door mounted M1 Main disconnect - 30 amps total pump load panel M2 Main disconnect - 60 amps total pump load panel

Test & Silence Switches

3214 3200 3201 3202 3203 3204 3205 3206 3215 3216 3217 3218 3219

3220 3207 3208 3209 3210 3211 3212 3213 3221 3222 3223 3224 3225

Check It Board Features HOA switch (Hand, Off, Auto) Check It switch (One button troubleshooting) Pump run indicator Float switch indicators Control power indicator Alarm power indicator Control power fuse (1amp) Alarm power fuse (1 amp) Telemetry and BAS ready (auxiliary contacts) Manual alarm reset (field convertible)

N Thermal cutout 6 Expandable - IEC only O Seal failure circuit and indicator Add ETM, Event Counter, P Single phase overload protection or Timed Dosing (specify amps) Q Low level (redundant off) circuit 7 Motor Protective Switch R External float weights S Anti-condensation heater 8 Multi-Tap Transformer T One wide angle float replaces two Unimax floats Includes 3 Mechanical U Control alarm circuit breaker Unimax control floats with V Alarm float only W Effluent filter switch 20’ cords W1 Amber beacon for a filter switch Dimensions W2 Amber beacon & filter switch Overall X No floats L x W x D Y Panel power post - panel mounted 15.56” 11.32” 7.28” on a post Mounting Holes For float cable lengths other than L x W 13.34” 8.56” 20’, specify length in the box below. Cord UL 508A US & Canada Length