SUPPORT PIPE - STANDARD OVERALL DIMENSION ALWAYS WIDER THAN BELT WIDTH CUT TO REQUIRED DIMENSION ON INSTALLATION
UP TO 1050 = 50 1200 UPWARDS = 60
FIXING CENTERS "L"
150
6
CL CONVEYOR TANGENT POINT ¹ 30 A
90 °
5
B
UP TO 1050 = 200 1200 UPWARDS = 210
"L"
NOTE: IDLER ROLL TO BE INSTALLED WITH DOWNWARD PRESSURE 200mm AFTER SCRAPER IF SCRAPER POSITION FURTHER BACK THAN 250mm FROM POINT B. FOR BELT SPEEDS GREATER THAN 5m/s MARTIN RECOMMENDS A SOLID ROLL.
1 7
60
SIDE VIEW
260 200
60 14
14
30
30
60
180 120
600 - 1200
500
60.5
48
1350 - UPWARDS
600
76
60
* INDICATES REPLACEMENT PARTS ITEM No.
QTY
1
1
QTY
BELT WIDTH
ITEM No.5 RUBBER BUFFER
ITEM No.5 BLADE
600
4
4
750
5
5
900
6
6
1050
7
7
1200
8
8
1350
9
9
1500
10
10
1650
11
11
1800
12
2000
1 PAIR 2 1 PAIR
SUPPORT PIPE STRINGER MOUNTING CHUTE MOUNTING DOUBLE SCRAPERS
¹ TANGENT POINT REFERS TO THE POINT WHERE THE BELT LEAVES THE PULLEY
XXXX SUPPORT PIPE
60 DIA CLAMP 600-1050 BW
3
2
COMPONENT DESCRIPTION
"G"
ØD
"F"
ØC
30
NOTE: XXXX INDICATES BELT WIDTH ie. 0750 FOR 750mm BELT WIDTH & 1800 FOR 1800mm BELT WIDTH "E"
L
60
80
58
BELT WIDTH
60
FRONT VIEW
OPENING 150
60
OUTSIDE DIMENSION OF CHUTE
FOR TENSIONING, APPLY 3 FULL TURNS
2
"H"
4
100
"Ø D"
"Ø C"
Ø14 UP TO 1050 @ 250 CRS 1200 UPWARDS @ 350CRS
3
OPENING UP TO 1050 = 300 1200 UPWARDS = 350
QTY OF BUFFERS x 150 (REF TABLE BELOW)
IT IS SUBMITTED FOR A SPECIFIED PURPOSE AND THE RECIPIENT, BY ACCEPTING THIS DOCUMENT AGREES 1. THAT THIS DOCUMENT WILL NOT BE COPIED OR REPRODUCED IN WHOLE OR IN PART, EXCEPT TO MEET THE PURPOSE FOR WHICH IT WAS DELIVERED, AND 2. THAT ANY SPECIAL FEATURES PARTICULAR TO THIS DESIGN WILL NOT BE INCORPORATED IN OTHER PROJECTS AND/OR DESIGNS. 3. THAT THIS IS NOT FOR PUBLIC DISTRIBUTION
APPROVAL
SC16 BUFFER
SIGN:
F.DE KLERK
SIGN:
S.ENSLIN
*
SC16 ARB SANDWICH
DATE:
06/05/2013
DATE:
06/05/2013
*
SC16 ARB *
THE INFORMATION CONTAINED WITHIN THIS DRAWING FILE INVOLVES CONFIDENTIAL PROPRIETARY DESIGN RIGHTS OF MARTIN.
MARKETING DEPT
PRODUCTION DEPT
SC16 SANDWICH
0
INITIAL RELEASE
06/05/2013
R.BEER
SIGN:
M.LEZAR
SIGN:
*
SC16 HAR
REV.
DESCRIPTION
DATE
APPROVED
DATE:
06/05/2013
DATE:
*
ADJUSTING BRKT
REVISIONS
SALES DEPT
WITBANK SOUTH AFRICA + 27 13 656 5135 www.martin-eng.co.za TITLE
MARTIN ENGINEERING WITBANK SOUTH AFRICA SC 16 600 - 2400 BW INSTALLATION DRAWING