WW Profile Photometric Report

Report 1 Downloads 52 Views
REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101918458

Date: March 17, 2014

REPORT NO. 101918458LAX-022 TEST OF ONE LED PROFILE MODEL NO. WW PROFILE 26°

RENDERED TO ELATION PROFESSIONAL 6122 S. EASTERN AVE COMMERCE, CA 90040 USA

TEST:

Electrical and Photometric tests as required to the IESNA test standard.

STATEMENT OF LIMITATION:

This report must not be used by the client to claim product certification, approval, or endorsement by A2LA, NIST, or any agency of the federal government.

AUTHORIZATION:

The testing performed was authorized by signed quote number Q500519256.

STANDARDS USED:

The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen:

IESNA LM-79 - 2008: Electrical and Photometric Measurements of Solid State Lighting

DESCRIPTION OF SAMPLE:

The client submitted one production sample of model number WW PROFILE 26°. The sample was received by Intertek on March 10, 2015, in undamaged condition and one sample was tested as received. The sample designation was LAN1503101019-003.

DATES OF TESTS:

March 16, 2015

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

SUMMARY Model No.: Description:

WW PROFILE 26° LED Profile

Criteria Total Lumen Output (Lumens) Total Power (W) Luminaire Efficacy (LPW)

Sphere 4805 174.3 27.57

Criteria Power Factor Current ATHD % Correlated Color Temperature (CCT - K) Color Rendering Index (CRI - Ra) Color Rendering Index (CRI - R9) DUV Chromaticity Coordinate (x) Chromaticity Coordinate (y) Chromaticity Coordinate (u') Chromaticity Coordinate (v')

Result Goniometer 4923 173.4 28.39

Result 0.975 4.08 3070 94.3 75.7 0.001 0.431 0.400 0.248 0.519

EQUIPMENT LIST

Equipment Used LabSphere Power Supply LapSphere 3M Integrating Sphere LabSphere Spectrometer California Instruments Power Supply Yokogawa Power Meter Extech Instruments Stop Watch Temperature Humidity Meter LSI High Speed Mirror Goniometer Elgar Power Supply Yokogawa Power Analyzer Temp. & RH Meter Extech Instruments Stop Watch Tape Measure

Report No. 101918458LAX-022

Model Number LPS-100-0833 CA-11821-LRT CDS-3020 CSW5550 WT333 C-510 971 6440T CW1251 WT210 971 365510 33-430

2 of 7

Control Number 000832 000830 000834 001338 001319 000351 001178 000943 000944 000945 001178 001390 001491

Last Date Calibrated 05/23/13 02/25/15 02/25/15 VBU 05/10/13 09/25/14 12/22/14 02/25/15 VBU 11/26/14 12/22/14 12/08/14 12/08/14

Calibration Due Date 05/20/15 03/25/15 03/25/15 VBU 05/15/15 09/25/15 12/22/15 03/25/15 VBU 11/26/15 12/22/15 12/08/15 12/08/15

Date: March 17, 2014

TEST METHODS Seasoning in Sample Orientation – LED Products No seasoning was performed in accordance with IESNA LM-79.

Photometric and Electrical Measurements – Integrating Sphere Method A Labsphere CDS 3020 Spectrometer and Three Meter Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. The calibration of the sphere spectrometer system is traceable to the National Institute of Standards and Technology. Photometric and Electrical Measurements – Distribution Method A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. Some graphics were created with Photometrics Plus software.

Report No. 101918458LAX-022

3 of 7

Date: March 17, 2014

RESULTS OF TEST Photometric and Electrical Measurements at Ambient Temperature (25°C +/- 1°C) - Integrating Sphere Method

Intertek Sample No. LAN1503101019-003

Correlated Color CRI Temperature (K) -Ra

3070

94.3

Input Input Input Voltage Current Power {Vac} (mA) (Watts) 119.9 1491 174.3

Base Orientation UP

CRI -R9 75.7

DUV 0.001

CIE 31’ Chromaticity Coordinate 0.431

Input Current Power ATHD Factor (%) 0.975 4.08

CIE 31’ Chromaticity Coordinate (y) 0.400

Luminous Flux (Lumens) 4805

CIE 76’ Chromaticity Coordinate (u’) 0.248

Lumen Efficacy (LPW) 27.57

CIE 76’ Chromaticity Coordinate (v’) 0.519

Spectral Distribution over Visible Wavelengths nm 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435

mW/nm -0.162 -0.225 -0.138 -0.188 -0.083 -0.107 -0.080 -0.089 -0.074 -0.014 0.050 0.202 0.526 1.184 2.279 4.061 6.605 10.290

nm 440 445 450 455 460 465 470 475 480 485 490 495 500 505 510 515 520 525

mW/nm 15.830 23.900 31.280 31.570 25.650 20.340 17.190 15.110 14.600 15.740 17.810 20.450 23.290 25.960 28.250 30.290 32.210 33.900

nm 530 535 540 545 550 555 560 565 570 575 580 585 590 595 600 605 610 615

mW/nm 35.750 37.440 39.210 40.800 42.250 43.590 44.720 45.840 46.770 47.740 48.770 49.880 51.050 52.550 54.620 56.780 58.790 60.610

nm 620 625 630 635 640 645 650 655 660 665 670 675 680 685 690 695 700 705

mW/nm 61.890 62.790 63.000 62.560 61.410 59.560 57.310 54.590 51.600 48.300 44.790 41.110 37.510 33.820 30.250 26.960 23.970 21.180

nm 710 715 720 725 730 735 740 745 750 755 760 765 770 775 780

mW/nm 18.660 16.390 14.400 12.560 10.780 9.226 7.947 6.798 5.828 4.978 4.317 3.664 3.118 2.642 2.257

Spectral Data Over Visible Wavelengths

70.000 60.000

(mW/nm)

50.000 40.000 30.000 20.000 10.000 0.000 350

400

450

500

550

600

650

700

750

800

Nanometers

Report No. 101918458LAX-022

4 of 7

Date: March 17, 2014

RESULTS OF TEST (cont'd) Photometric and Electrical Measurements at Ambient Temperature (25°C +/- 1°C) – Distribution Method

Intertek Sample No. LAN1503101019-003

Base Orientation UP

Input Input Input Voltage Current Power {Vac} (mA) (Watts) 120.0 1533 173.4

Input Absolute Lumen Efficacy Power Luminous Flux (Lumens Per Factor (Lumens) Watt) 0.942 4923 28.39

Intensity (Candlepower) Summary at 25°C - Candelas Maximum Candela Value: 38,316.9 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

0 22.5 45 32477 32477 32477 35325 35240 35201 35962 36270 36106 40 41 18 29 13 27 20 23 14 12 9 7 0 16 2 0 12 16 9 0 0 0 0 21 26 2 0 0 4 0 0 0 0 0 0 9 0 0 0 7 2 0 0 0 0 7 0 0

Report No. 101918458LAX-022

67.5 32477 34973 36314 63 10 17 14 11 0 7 16 0 5 0 1 0 6 3 0

90 32477 34930 36575 56 23 16 13 2 13 0 8 6 0 0 4 15 0 11 9

X

5 of 7

Date: March 17, 2014

RESULTS OF TEST (cont'd) Illumination Plots Mounting Height: 10 ft. Illuminance - Cone of Light

Isoillumination Plot

X

X

Zonal Lumens and Percentages at 25°C

Zonal Lumen Summary and Percentages at 25°C Zone Lumens 0-30 4901 0-40 4904 0-60 4912 60-90 10.3 0-90 4923 90-180 0.3 0-180 4923

Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100

% Luminaire 99.5 99.6 99.8 0.2 100.0 0.0 100.0

Report No. 101918458LAX-022

6 of 7

Lumens 3439 1450 11.3 3.9 3.1 4.9 3.7 3.6 3.0 0.3

% Luminaire 69.9 29.5 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0

Date: March 17, 2014

PICTURE (not to scale) X

CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report.

In Charge Of Tests:

Report Reviewed By:

Ameet Alawi Technician Lighting Division

Kenda Branch Lighting Performance Team Lead Lighting Division

Attachment: None

Report No. 101918458LAX-022

7 of 7

Date: March 17, 2014