ELED TW Strip WW Photometric Test Report (pdf)

Report 2 Downloads 75 Views
Test #: L09133803 Date: 10/9/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 Test Report:

L09133803

Model Number:

ELED Strip TW WW

Report Prepared For:

Test:

NVLAP LAB CODE 200927‐0 

ELATION LIGHTING 6122 S. EASTERN AVE, COMMERCE, CA 90040

Electrical and Photometric tests as required by the IESNA test standards.

Standards Used: Appropriate part or all test guidelines were used for test performed: IESNA LM79: 2008 Approved Methods for Electrical and Photometric Measurements of Solid-State Lighting Products ANSI NEMA ANSLG C78.377: 2008 Specification of the Chromaticity of Solid State Lighting Products ANSI C82.77:2002: Harmonic Emission Limits-Related Quality Requirements for Lighting Equipment Description of Sample:

Client submitted the sample. Fixture catalog number is ELED Strip TW WW. Received in working and undamaged condition. No modifications were necessary.

Testing Condition:

Fixture is tested with no special conditions.

Sample Arrival Date:

9/5/13

Date of Tests:

10/9/13



10/9/13

Seasoning of Sample SSL: No seasoning was performed in accordance with IESNA LM-79.

Equipment List

Equipment Used Chroma Programmable AC Source Yokogawa Digital Power Meter Xitron Power Analysis System Fluke Digital Thermometer LLI Type C Goniophotometer System LLI 2M Sphere LLI Spectroradiometer

Model No

Stock No

Calibration Due Date

61604 WT210 2503AH 52k/J RMG-C-MKII 2MR97 SPR-3000

PS-AC02 MT-EL06-S1 MT-EL01 MT-TP02-GC CD-LL04-GC CD-SN03-S2 MT-SC01-S2

-01/04/14 01/09/14 01/04/14 --Before Use

*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.

Page 1 of 4

Page 2 of 4

Test #: L09133803 Date: 10/9/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558

NVLAP LAB CODE 200927‐0 

Spectral Power 

Percent Output 

1.0 0.8 0.6 0.4 0.2 0.0 380 Wavelength

W/m2nm

380 390 400 410 420 430

0.0008 0.0002 0.0001 0.0002 0.0011 0.0039

CRI & CCT x 0.4369 y 0.4034 u' 0.2508 v' 0.5211 CRI 77.20 CCT 2994 Duv ‐0.00027 R Values R1 75.10 R2 85.21 R3 91.94 R4 73.14 R5 72.48 R6 77.40 R7 83.74 R8 58.46 R9 3.10 R10 63.25 R11 66.47 R12 51.51 R13 77.16 R14 94.77

430

440 450 460 470 480 490 500

480

0.0092 0.0193 0.0168 0.0094 0.0059 0.0053 0.0069

530

510 520 530 540 550 560 570

580 Wavelength(nm)

0.0109 0.0156 0.0198 0.0235 0.0266 0.0295 0.0322

580 590 600 610 620 630 640

630

0.0347 0.0362 0.0370 0.0365 0.0348 0.0316 0.0278

680

650 660 670 680 690 700 710

730

0.0242 0.0202 0.0164 0.0132 0.0103 0.0081 0.0062

780

720 730 740 750 760 770 780

0.0047 0.0036 0.0027 0.0021 0.0016 0.0013 0.0010

CIE 1931 Chromaticity Diagram 

Y 0.9 520 

0.8

530  540 

510 

0.7

550  560 

0.6

570 

500 

0.5

580  590 

0.4

0.4369, 0.4034  0.3

600  610  620  630  640  650  700 

490 

0.2 480 

0.1 0 0

0.1

470  460  440  430  380 

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

X

*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.

Page 3 of 4

Page 4 of 4

IES FLOOD REPORT PHOTOMETRIC FILENAME : L09133803.IES DESCRIPTIVE INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] L09133803 [TESTLAB] LIGHT LABORATORY, INC. [ISSUEDATE] 10/9/2013S [MANUFAC] ELATION LIGHTING [LUMCAT] ELED Strip TW WW [LUMINAIRE] 8-1/4"L. X 40"W. X 8-1/2"H. LED LUMINAIRE [MORE] CLEAR LENS [LAMPPOSITION] 0,0 [LAMPCAT] N/A [OTHER] INDICATING THE CANDELA VALUES ARE ABSOLUTE AND [MORE] SHOULD NOT BE FACTORED FOR DIFFERENT LAMP RATINGS. [_INPUT] 120VAC, 39.27W [_TEST PROCEDURE] IESNA:LM-79-08 Note: Candela values converted from Type-C to Type-B CHARACTERISTICS NEMA Type Maximum Candela Maximum Candela Angle Horizontal Beam Angle (50%) Vertical Beam Angle (50%) Horizontal Field Angle (10%) Vertical Field Angle (10%) Lumens Per Lamp Total Lamp Lumens Beam Lumens Beam Efficiency Field Lumens Field Efficiency Spill Lumens Luminaire Lumens Total Efficiency Total Luminaire Watts Ballast Factor

5Hx4V 954 -1H -1V 42.5 39.5 73.5 64.8 N.A. (absolute) N.A. (absolute) 288 N.A. 459 N.A. 70 529 N.A. 39.27 1.00

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.

Page 1

IES FLOOD REPORT PHOTOMETRIC FILENAME : L09133803.IES AXIAL CANDELA DEG.

HOR.

DEG.

VERT.

90 85 75 65 55 47.5 42.5 37.5 33 29 25.5 22.5 19.5 17 15 13 11 9 7 5 3 1 0 -1 -3 -5 -7 -9 -11 -13 -15 -17 -19.5 -22.5 -25.5 -29 -33 -37.5 -42.5 -47.5 -55 -65 -75 -85 -90

0 4 4 7 13 25 44 85 149 230 331 434 534 614 672 729 784 833 877 913 937 950 954 950 937 913 877 833 784 729 672 614 534 434 331 230 149 85 44 25 13 7 4 4 0

90 85 75 65 55 47.5 42.5 37.5 33 29 25.5 22.5 19.5 17 15 13 11 9 7 5 3 1 0 -1 -3 -5 -7 -9 -11 -13 -15 -17 -19.5 -22.5 -25.5 -29 -33 -37.5 -42.5 -47.5 -55 -65 -75 -85 -90

0 3 4 6 11 17 25 42 83 168 268 374 487 578 653 729 800 861 907 938 952 953 954 953 952 938 907 861 800 729 653 578 487 374 268 168 83 42 25 17 11 6 4 3 0

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.

Page 2

IES FLOOD REPORT PHOTOMETRIC FILENAME : L09133803.IES AXIAL CANDELA DISPLAY

954

716

477 H

239 V

-90

-60

-30

0

30

60

90

Maximum Candela = 954 Located At Horizontal Angle =-1, Vertical Angle =-1 H - Horizontal Axial Candela V - Vertical Axial Candela

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.

Page 3

IES FLOOD REPORT PHOTOMETRIC FILENAME : L09133803.IES ISOCANDELA CURVES 60

40 95.4 190.8 286.2 20

477 667.8 858.6

Vertical Angles

0

-20

-40

-60

0

20

40

60

Horizontal Angles

Maximum Candela = 954 Located At Horizontal Angle =-1, Vertical Angle =-1 50% Maximum Candela = 477 10% Maximum Candela = 95.4

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.

Page 4