Electric Heated - Whaley Foodservice

Report 4 Downloads 259 Views
No.: Date:

KSB

DS-338 May, 2007

Electric Heated Data Sheet

STANDARD FEATURES ‹ 1 hp single speed motor(s) ‹ Factory mounted control panel - 24 volt control ‹ Galvanized steel blower wheels and housing ‹ Airfoil aluminum air directional vanes ‹ Powder coated finish with aluminum inlet screen ‹ 16 gauge aluminized steel cabinet ‹ ½” mounting holes (wall or top mount) ‹ UL Listed (United States and Canada) ‹ Two year parts warranty ‹ Crafted wtih Pride in the USA

Model KSB1036E KSB1042E KSB1048E KSB1060E KSB2060E KSB2072E KSB2078E KSB2084E KSB2096E KSB3096E KSB2108E KSB3108E KSB2120E KSB3120E KSB3132E KSB3144E KSB4144E

Avg. Max. Nozzle Air Outlet Width Velocity Volume Velocity (fpm) (in) (scfm) (fpm) 36 5000 2738 2396 42 5000 2435 2486 48 5000 2173 2535 66 5000 1668 2433 66 5000 3136 4574 72 5000 2738 4792 78 5000 2575 4882 84 5000 2435 4972 99 5000 2173 5070 99 5000 2942 6865 108 5000 1893 4968 108 5000 2738 7188 117 5000 1668 4866 117 5000 2526 7368 132 5000 2340 7507 144 5000 2173 7605 144 5000 2738 9584

HEATER FEATURES ‹ Helical coil with point suspension of elements ‹ Available single or three phase ‹ Galvanized steel frame ‹ Thermally protected against overheating OPTIONAL FEATURES ‹ Reduced kW available (see sheet KW-337) ‹ Multi-speed motor(s) (consult factory)

Electric Outlet Power Motor(s) Rating Velocity Capacity @ hp (kW) (kW) Unif. (%) 1@1 1@1 1@1 1@1 2@1 2@1 2@1 2@1 2@1 3@1 2@1 3@1 2@1 3@1 3@1 3@1 4@1

1.12 1.12 1.25 1.25 2.07 2.24 2.24 2.24 2.50 3.36 2.50 3.36 3.36 3.36 3.49 3.75 4.48

87 81 84 72 97 87 81 81 84 88 72 87 72 81 81 84 87

14 14 14 14 28 28 28 28 28 42 28 42 28 42 42 42 54

Heater Temp. Capacity Rise (°F) (BTU/hr) 47,782 47,782 47,782 47,782 95,564 95,564 95,564 95,564 95,564 143,346 95,564 143,346 95,564 143,346 143,346 143,346 184,302

18 18 17 18 19 18 18 18 17 19 18 18 18 18 18 17 18

Net Wgt. (lbs)

Ship Wgt. (lbs)

101 107 112 123 190 199 205 210 220 281 263 324 270 331 352 366 427

123 132 141 159 226 242 252 260 278 339 328 389 342 403 431 452 513

Air performance based on AMCA licensed data from base (unheated) units *Reduced kW heaters available, see sheet KW-337

VOLTS PHASE HERTZ* AMPS per MOTOR

MOTOR VOLTAGES/AMP 120 208 240 208 240 1 1 1 3 3 60 60 60 60 60 12 6.5 6.3 4.6 4.4

DRAWS 480 600 3 3 60 60 2.3 1.4

190 3 50 4.5

220 1 50 6.5

380 3 50 2.2

*Operation at 50 Hz will generate approximately a 17% reduction in performance.

Sound level measured 10’ (3M) from the unit in free field:

63 dBA

Berner reserves the right to alter specifications without prior notice. Berner International Corporation New Castle, PA 16101 / USA / Telephone (724) 658-3551 / FAX (724) 652-0682 / www.berner.com / [email protected] MADE IN U.S.A.

©Copyright, 2007 Berner International Corporation