Hanger Options - Alera Lighting

Report 2 Downloads 70 Views
HANGER OPTIONS PENDANT OPTIONS S18 - STEM, NON-SWIVEL

SS18 - STEM, SWIVEL 45° SWIVEL FROM VERTICAL

TECHNICAL

Nut

PM - FEED STEM W/J-BOX, NON-SWIVEL J-Box with fixture stud (furnished by electrical contractor)

Swivel Suspension Plate

Suspension Plate

Crossbar Canopy Ceiling Canopy with Slip Ring

Canopy

Stem (⅝" OD)

Stem (⅝" OD) Stem (⅝" OD)

⅜" IP Hex Nut

Slip Ring with Screw

Screw

Locknut Locknut

Washer

Wastenut Locknut

Locknut

PMS - SLOPED CEILING STEM 45° SWIVEL FROM VERTICAL

Small Hex Nut

PMR - EARTHQUAKE STEM W/CABLE 45° SWIVEL FROM VERTICAL

Visual Leveling Scale

Ceiling Bracket Visual Leveling Scale

Canopy K.O. in fixture channel

Canopy Stem (⅝" OD) Rocker Fitting Kit

Wastenut Kit Standard ⅝"

182

Cable Earthquake

⅜" IP Hex Nut

PENDANT OPTIONS ARE NOT AVAILABLE FOR ALL FIXTURE TYPES. CONTACT FACTORY FOR DETAILS.

Ceiling Bracket

Stem (⅝" OD)

K.O. in fixture channel

K.O. in fixture channel

HANGER OPTIONS CABLE OPTIONS FEED

NON-FEED J-Box Strap w/ ground screw

Ceiling Plate 5"

WASTENUT KIT NOT REQUIRED

T-Bar Caddy Clip*

Stud

ALS1, CV2, QST2, SLS1, SOLO1

Ceiling Plate 2" (optional)

1

TECHNICAL

T-Bar Caddy Clip*

⅜" IP Hex Nut ¼" IP Hex Nut

2

Ceiling Plate 5" (standard)

Bushing Coiled Cord (optional)

Cable Assembly (see options below)

Cable Assembly (see options below)

SJT Power Cord

Bushing Wastenut Kit if required

Wastenut Kit if required *Add TBAR in the suffix of the catalog number if required.

CABLE ASSEMBLY OPTIONS

FCM

CM

CM

CM

CVL 2-L, CVR 2-L, QST

CV, CVPL, CVSL, M, MM

CM

ALS, SLS, SOLO

CPLS, CVL 1-L, CVL 3-L, CVR 1-L, CVR 3-L, MDI NPLS, NVS, PLK, PPLS

T-BAR MOUNTING OPTION

JUNCTION BOX ACCESSORY FOR DROP CEILING INSTALLATION

Alera cable hangers can be installed directly to the T-Bar grid. The IDS clip and additional length of SJT cord will be supplied when the suffix “TBAR” is added to the catalog number.

#93016675- ordered separately

Feed End

• Complies with Article 400.8 NEC with issues concerning cords thru drop ceilings

Non-Feed End Support Wire to Structure (by others)

4" Octagonal J-Box by others

¼" Flex to Junction Box (by others)

T-Bar Clip with ¼-20 Screw

5" Canopy

Ceiling Tile (by others)

Strain Relief Bushing

¼-20 Internal Thread Ceiling Coupler Cable Hanger Assembly

T-Bar Clip T-Bar (by others)

5" Canopy (2” Canopy option) Aircraft Cable

Feed Cord Snap-In Bushing

• 2⅛" deep octagonal box to mount over T-Bar

• Independent support tab provided on back of box for independent support for both junction box and attached lighting fixture. • Ground screw hole location and ½" knockouts located for easier access after mounting. • Knockouts provided for regular type ceiling tiles to keep junction box flush with ceiling tile edge.

3.56" Square

Drop Ceiling Junction Box Drop Ceiling T-Bar By Others (For Drop Ceiling Application)

2.16" Height

¼"-20 × ¾"L Philips Flat Head Screw Countersunk ¼"-20 Gem Bar 3.5" C to C

8/32" Mounting Screws

Connect feed wires to fixture as required

183