SOLO - Alera Lighting

Report 33 Downloads 126 Views
SOLO 1, 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution PROJECT INFORMATION Project Name

Type

Catalog No.

Date

MOUNTING —The aircraft cable assembly is adjustable.

—Reinforced to provide maximum rigidity across the entire housing.

—Precise horizontal balancing is accomplished by sliding a cable gripper along a metal yoke on each end.

DI SC ON TIN UE D

CONSTRUCTION —4', 8' and 12' housings

—End caps are made of 16-gauge construction and attach with nuts and bolts.

FEATURES

• Contemporary low profile appearance with octagonal sides • Direct/Indirect Luminaires • One, two, or three T8, T5, or T5HO lamps • Steel housing • Controls compatible • High efficiency with wide distribution • Modular suspension points offer ease of installation • Adjustable yoke cable hanger allows vertical adjustments and horizontal balancing • Fixed louver stays in housing, even if fixture is struck or damaged

—Aligners are supplied for intermediate connection points, providing sturdy attachment for straight continuous rows. —Upper reflectors are specular anodized aluminum for precise upward distribution —Relamped from above

FINISH The housing is finished with a baked powder coat matte white finish as standard. End caps and intermediate aligners are painted to match the housing. Hanging stems and canopies are painted white. Cable fittings are standard chrome.

SHIELDING —Louvers: securely attached to the housing from the top, eliminating any chance of loosening or falling from the fixture.

2¾"

91/2"

ORDERING INFORMATION

MODEL Solo Solaris Octagonal

ROW LENGTH 4' Single 8' Single 12' Single Indicate row length over 12' in 4' increments Note: Rows over 12' will be configured by Alera. Example: 16' will be (2) 8'. Alternate configurations: contact factory. (12' not available in WM) 4 8 12 —



—Available with rigid stem mount.

LABELS AND ELECTRICAL —All luminaires are built to UL1598 standards and bear appropriate UL and cUL or CSA labels. —Damp location labeling is standard. —Quick connect plugs standard. Name: Test #: Efficiency: LER:

SOLO-2T8-LD-E 12635 92.9% 76

EXAMPLE: SOLO-8-2T8-CM48-LD-EU-ZT



LAMP TYPE AND PROFILE 1T5 One T5 Lamp1 2T5 Two T5 Lamps1 3T5 Three T5 Lamps1 1T5HO One T5HO Lamp1 2T5HO Two T5HO Lamps1 3T5HO Three T5HO Lamps1 1T8 One T8 Lamp 2T8 Two T8 Lamps 3T8 Three T8 Lamps





MOUNTING CM Adjustable Aircraft Cable Mount (Std.) WM Wall Mount PM Pendant Mount See HGR-1 for other hanging methods.

DISTRIBUTION 60% Uplight, 40% Downlight 0% Uplight, 100% Downlight2 20% Uplight, 80% Downlight2 40% Uplight, 60% Downlight2 85% Uplight, 15% Downlight 100% Uplight, 0% Downlight (Fully indirect) CLC Center Lamp Cover for A/V Mode2

Blank 0/100 20/80 40/60 85/15 100/0

—The double hanging system allows the suspension points to be placed on 48" centers for quick and easy installation.

—LD: semi-specular anodized aluminum, eleven-cell louver measures 11⁄2" high and provides maximum efficiency and a glare-free environment. The aluminum finish will remain dust and fingerprint free.

SHAPE AND DIMENSIONS

SOLO —

—The cable gripper is simply turned and locked into place once the fixture is leveled.



SHIELDING LD Low Iridescent Semi-Specular (Std.) LS Low Iridescent Specular LD18 18-Cell Low Iridescent SemiSpecular Louver

SUSPENSION LENGTH 18 18" 24 24" 36 36" 48 48" 96 96" N/A for WM. Other lengths available on request.



U 120 277 347

VOLTAGE 120V-277V 120V 277V 347V

BALLAST E Electronic, Instant Start, (Std. for T8) EP Electronic, Programmed Start (Std. for T5 and T5HO, optional for T8) ED Electronic, Dimming (Must specify) Unless specified, Alera will use fewest ballasts possible.



FINISH MW Matte White ZT Zet Metallic Silver

See Color Selection Guide for other color selections

OPTIONS DC Dust Cover2,6 LR Left/Right Switching (2-Lamp only) IBOB Inboard/Outboard Switching (3-Lamp only) EL One Emergency Battery Pack3, 4 EMC One Emergency Circuit4, 5 NLC Night Light Circuit4, 5 GLR Fast Blow Fuse GMF Slow Blow Fuse TBAR T-Bar Mounting

T5/T5HO at risk for socket shadow in downlight component. Dust cover not available when using these optical distribution covers. 3 Specify voltage. For additional, specify quantity before nomenclature (Example: 2EL120). 4 Not available with all configurations; some limitations apply. Contact factory for details. 5 One extra feed drop per EMC or NLC. (Standard is one 4ft lamp per circuit.) For through wiring, please contact factory. 1 2

Page 1/3 Rev. 12/19/16

CURVES / SOLO.indd

© 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

SOLO 1, 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution CROSS SECTION

2¾"

2¾"

DI SC ON TIN UE D

2¾"

9½" SOLO-1T8

9½" SOLO-2T8

9½" SOLO-3T8

PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

SOLO-2T8-LD-EB8 Solo Architectural Curve 9" × 48" 2 LAMP WITH 1 × 11 CELL SEMISPECULAR LOUVER RCN-2P32-SC 0.88 F32T8 2900 62 Pendant 0º = 21  90º = 24 0º = 1.20  90º = 1.31 Length: 3.80 Width: 0.37 Height: 0.00

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

5711 5322 4907 4526 4026 3390 2480 1359 269 177 132 176

5711 5852 5467 5078 4562 3884 2970 1884 694 296 220 176

5711 5932 5706 5435 5300 5152 5374 4311 1947 503 353 264

5711 5994 5786 6085 6622 8209 7503 5127 1724 769 485 439

5711 5994 5876 6334 7718 9503 8590 5090 1500 828 573 439

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 611 995 1774 2005 1161 1754 2745 3385 5390

10.5 17.2 30.6 34.6 20.0 30.2 47.3 58.4 92.9

11.3 18.5 32.9 37.2 21.5 32.5 50.9 62.8 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test 12635

RC RW 1 2 3 4 5 6 7 8 9 10

70 89 81 74 68 62 57 53 49 45 42

80 50 30 85 82 75 69 66 59 58 51 52 44 46 39 42 34 38 31 34 27 31 25

10 79 65 54 46 39 34 29 26 23 20

70 80 73 67 61 56 52 48 44 41 38

70 50 30 77 74 68 63 60 54 53 47 47 41 42 36 38 32 35 28 31 25 29 23

10 72 60 50 42 36 31 27 24 21 19

50 63 55 49 43 39 35 32 29 26 24

50 30 61 52 45 39 34 30 27 24 22 19

10 59 49 42 36 31 27 23 21 18 16

INDOOR CANDELA PLOT

0 0 30 26 22 19 16 14 13 11 10 9

165

180

150

135

900

120

450

105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75

450

ENERGY DATA

60

Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

92.9% 76 Yes-VDT Normal Use $3.16 based on 3000 hrs. and $0.08 per KWH

900

0

15 30 Horiz 0-180 90.0 45.0

0.0

45

Test Date 9/12/00

PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

SOLO-2T885/15-LD-EB8 Solo Architectural Curve 9" × 48" 2L W/ 1X11 CELL SEMI-SPEC LOUVER & DOWNLIGHT SCREEN RCN-2P32-SC 0.88 F32T8 2900 63 Pendant 0º = 90  90º = 90 0º = 1.08  90º = 1.16 Length: 3.80 Width: 0.37 Height: 0.00

Page 2/3 Rev. 12/19/16

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

2725 2219 1879 1657 1405 1108 781 417 90 59 88 176

2725 2404 1969 1711 1417 1108 796 507 269 237 220 176

2725 2431 1969 1689 1501 1268 980 725 470 207 132 0

2725 2466 2029 1906 1751 1468 1072 851 425 237 132 0

2725 2458 2099 2014 1882 1562 1179 996 381 207 132 0

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 273 421 636 685 1389 2142 3437 4295 4980

4.7 7.3 11.0 11.8 23.9 36.9 59.3 74.1 85.9

5.5 8.5 12.8 13.8 27.9 43.0 69.0 86.2 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test 12636

RC RW 1 2 3 4 5 6 7 8 9 10

70 77 71 64 59 54 50 46 42 39 37

80 50 30 74 71 65 60 57 51 50 44 45 38 40 34 36 30 33 26 29 24 27 21

10 68 56 47 40 34 29 25 22 19 17

70 68 62 56 51 47 43 40 37 34 32

70 50 30 65 62 57 53 50 45 44 39 40 34 35 30 32 27 29 24 26 21 24 19

10 60 50 42 35 30 26 23 20 18 16

50 48 42 37 33 30 27 24 22 20 18

50 30 46 40 34 30 26 23 20 18 16 15

10 45 37 32 27 23 20 18 16 14 12

INDOOR CANDELA PLOT

0 0 11 9 8 7 6 6 5 5 4 4

180

165

150

120

550

105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75

550

ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

85.9% 70 Yes-VDT INTENSIVE USE $3.43 based on 3000 hrs. and $0.08 per KWH

135

1100

60 1100 0 0.0

15 30 Horiz 0-180 90.0 45.0

45

Test Date 9/12/00 CURVES / SOLO.indd

© 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

SOLO 1, 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution PHOTOMETRIC DATA AVG. LUMINANCE (Candela/Sq. M.) 0 30 40 45 50 55 60 65 70 75 80 85

0.0

8972 8380 7755 7146 6360 5339 3889 2065 358 266 220 176

COEFFICIENTS OF UTILIZATION (%)

22.5 45.0 67.5 90.0 8972 9220 8825 8326 7611 6660 5328 3351 940 414 353 264

8972 9715 9734 9755 9457 8342 6798 4855 2104 651 441 264

8972 10148 11023 10892 10314 9383 8008 5271 1903 947 617 351

8972 10237 11363 11195 10791 10264 8881 5326 1724 1006 661 351

RC RW 1 2 3 4 5 6 7 8 9 10

70 86 78 72 66 60 55 51 47 44 41

80 50 30 82 79 72 67 64 58 56 50 50 43 45 38 41 34 37 30 33 27 31 24

10 76 63 53 45 38 33 29 25 23 20

70 78 71 65 60 55 50 46 43 40 37

70 50 30 75 72 66 62 58 53 52 46 46 40 41 35 37 31 34 28 31 25 28 23

10 70 58 49 42 36 31 27 24 21 19

50 62 54 48 43 38 35 31 28 26 24

50 30 60 51 45 39 34 30 27 24 22 19

10 58 49 41 35 31 27 23 21 18 16

INDOOR CANDELA PLOT 0 0 31 27 23 20 18 15 14 12 11 10

180

165

150

135

1300 120 650

DI SC ON TIN UE D

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

SOLO-3T8-LD-EB8 Solo Architectural Curve 9" × 48" 3 LAMP WITH 1X11 CELL SEMISPECULAR LOUVER B332I120RH-A 0.88 F32T8 2900 89 Pendant 0º = 21  90º = 23 0º = 1.20  90º = 1.49 Length: 3.80 Width: 0.37 Height: 0.00

RCR

Luminaire

Angle

LUMINAIRE DATA Test 12637

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Page 3/3 Rev. 12/19/16

Lumens % Lamp % Fixt. 970 1620 2833 3112 1310 2133 3626 4608 7720

11.2 18.6 32.6 35.8 15.1 24.5 41.7 53.0 88.7

12.6 21.0 36.7 40.3 17.0 27.6 47.0 59.7 100.0

105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75

650

ENERGY DATA

Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

60

88.7% 76 Yes-VDT Normal Use $3.16 based on 3000 hrs. and $0.08 per KWH

1300

0

0.0

15 30 Horiz 0-180 90.0 45.0

45

Test Date 9/12/00

CURVES / SOLO.indd

© 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Recommend Documents