SOLARIS 1, 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution PROJECT INFORMATION Project Name

Type

Catalog No.

Date

CONSTRUCTION

MOUNTING

—4', 8', and 12' housings

CM- Solaris utilizes a unique hanging system that makes vertical and horizontal adjustment effortless. The aircraft cable assembly is totally adjustable. Precise horizontal balancing is accomplished by sliding a cable gripper along a metal yoke on each end. The cable gripper is simply turned and locked into place once the fixture is leveled. The double hanging system allows the suspension points to be placed on 48" centers for quick and easy installation.

—Reinforcement provided to ensure maximum rigidity across the entire housing.

FEATURES • Optional distribution covers allow the designer to maintain a single look throughout a facility while varying the light distribution • Direct/Indirect distribution • T8, T5, or T5HO lamps • Heavy 20-gauge steel construction provides excellent housing rigidity • Controls compatible • Adjustable 48" (CM48) aircraft cable yoke hanger with vertical and horizontal balancing • Patented die cast couplers and end caps ensure straight rows with no light leak • Fixed louver stays in housing, even if fixture is struck or damaged • Popular for educational and general office commercial facilities, also excellent for retail

—Diecast aluminum end caps provide zero tolerance alignment between fixtures, resulting in consistently straight rows with no snaking. —Upper reflectors are constructed of specular anodized aluminum for precise upward distribution.

PM—Rigid stems available

—Relamped from above

FINISH The housing is finished with a baked powder coat matte white finish as standard. Diecast end caps and intermediate couplers are painted to match the housing. Hanging stems and canopies are painted white. Cable fittings are standard chrome.

2 3/4"

LABELS AND ELECTRICAL —All luminaires are built to UL1598 Standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard.

SHIELDING

—Quick-connect plugs standard.

Louvers attach securely to the housing from the top, eliminating any chance of loosening or falling from the fixture.

CONTROLS COMPATIBILITY

—Constructed of semi-specular anodized aluminum, the eleven-cell louver (LD) measures 1½" high and provides maximum efficiency and a glare-free environment. The aluminum finish will remain dust and fingerprint free.

SHAPE AND DIMENSIONS

WM—Mounts directly to and is flush with the wall

Controls compatible. When used with Occupancy Sensors, most lamp vendors recommend Program Rapid Start (EP) to extend lamp life. Common control schemes: Switching (IB/OB or L/R), 0-10V Dimming ballast (ED). Compatibility with specific control (example, dimmer switch) is by others.

—Specular aluminum is available (LS). A variety of lenses are available with the Solaris.

91/2"

Name: Test #: Efficiency: LER:

—The lenses slide into a track in the bottom of the extrusion to make it completely captive. This captivity makes the lensed Solaris ideal for laboratories, hallways, or schools.

ORDERING INFORMATION

SLS



MODEL SLS Solaris

4 8 12 —

ROW LENGTH 4' Single 8' Single 12' Single Indicate row length over 12' in 4' increments



EXAMPLE: SLS-8-2T8-CM48-LD-EU-MW-LR



LAMP TYPE AND PROFILE 1T5 One T5 Lamp1 2T5 Two T5 Lamps1 3T5 Three T5 Lamps1 1T5HO One T5HO Lamp1 2T5HO Two T5HO Lamps1 3T5HO Three T5HO Lamps1 1T8 One T8 Lamp 2T8 Two T8 Lamps 3T8 Three T8 Lamps

Note: Rows over 12' will be configured by Alera. Example: 16' will be (2) 8'. Alternate configurations: contact factory.

Blank 0/100 20/80 40/60 85/15 CLC 100/0





MOUNTING METHOD CM Adjustable Aircraft Cable Mount (Std.) PM Pendant Mount WM Wall Mount

DISTRIBUTION 60% Uplight, 40% Downlight 0% Uplight, 100% Downlight2,6 20% Uplight, 80% Downlight2,6 40% Uplight, 60% Downlight2,6 85% Uplight, 15% Downlight2,6 Center Lamp Cover for A/V Mode2,6 100% Uplight, No Downlight (Fully Direct, No Louver)

2





SHIELDING LD Low Iridescent Semi-Specular Louver (Std.) LS Low Iridescent Specular Louver LD18 Low Iridescent Semi-Specular 18-Cell Louver LS18 Low Iridescent Specular 18-Cell Louver WL White Louver A12 Pattern 12 Acrylic Lens A19 Pattern 19 Acrylic Lens MA Matte Anodized Louver

SUSPENSION LENGTH 18 18" 24 24" 36 36" 48 48" 96 96" N/A for WM and SM. Other lengths available on request.

T5/T5HO at risk for socket shadow in downlight component. Dust cover not available when using these optical distribution covers. 3 Specify voltage. For additional, specify quantity before nomenclature (Example: 2EL120). 4 Not available with all configurations; some limitations apply. Contact factory for details. 5 One extra feed drop per EMC/NLC. For through wiring, contact factory. 6 Ships separately. 1

SLS-2T8-LD-E 12479 92.9% 76

U 120 277 347

VOLTAGE 120V-277V 120V 277V 347V4

BALLAST E Electronic, Instant Start, (Std. for T8) EP Electronic, Programmed Start (Std. for T5 & T5HO, optional for T8) ED Electronic, Dimming (Must specify) ESD Electronic, Step Dimming ELW Electronic T8, Low Wattage, Instant Start EPLW Electronic T8, Low Wattage, Programmed Start Unless specified, Alera will use fewest ballasts possible.

DC BN LR IBOB EL EMC NLC GLR GMF TBAR FO841 F5841 FO835 F5835

— FINISH MW Matte White (Std.) ZT ZET Metallic Silver See Color Selection Guide for other colors. OPTIONS Dust Cover (N/A T5HO)2, 6 Bull Nose End Cap6 Left/Right Switching (2-Lamp only) Inboard/Outboard Switching (3-Lamp only) One Emergency Battery Pack3, 4 One Emergency Circuit4, 5 Night Light Circuit4, 5 Fast Blow Fuse Slow Blow Fuse T-Bar Mounting With T8 4100K Lamp Installed With T5/T5HO 4100K Lamp Installed With T8 3500K Lamp Installed With T5/T5HO 3500K Lamp Installed

Page 1/3 Rev. 11/08/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

CURVES / SLS

SOLARIS 1, 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution CROSS SECTION

23/4"

23/4" 91/2" SLS-1T8

23/4"

91/2" SLS-2T8

23/4"

91/2" SLS-3T8

9" SLS-2T8-WM

PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

SLS-3T8-LD-EB8 Solaris Architectural Curve 9" × 48" 3 LAMP WITH 1 × 11 CELL SEMISPECULAR LOUVER B332I120RH-A 0.88 F32T8 2900 89 0º = 21  90º = 23 0º = 1.20  90º = 1.49 Length: 3.80 Width: 0.37 Height: 0.00

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5

8972 8380 7755 7146 6360 5339 3889 2065 358 266 220 176

8972 9220 8825 8326 7611 6660 5328 3351 940 414 353 264

8972 9715 9734 9755 9457 8342 6798 4855 2104 651 441 264

8972 10148 11023 10892 10314 9383 8008 5271 1903 947 617 351

90.0

8972 10237 11363 11195 10791 10264 8881 5326 1724 1006 661 351

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 970 1620 2833 3112 1310 2133 3626 4608 7720

11.2 18.6 32.6 35.8 15.1 24.5 41.7 53.0 88.7

12.6 21.0 36.7 40.3 17.0 27.6 47.0 59.7 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test I2436

RC RW 1 2 3 4 5 6 7 8 9 10

70 86 78 72 66 60 55 51 47 44 41

80 50 30 82 79 72 67 64 58 56 50 50 43 45 38 41 34 37 30 33 27 31 24

10 76 63 53 45 38 33 29 25 23 20

70 78 71 65 60 55 50 46 43 40 37

70 50 30 75 72 66 62 58 53 52 46 46 40 41 35 37 31 34 28 31 25 28 23

10 70 58 49 42 36 31 27 24 21 19

50 62 54 48 43 38 35 31 28 26 24

50 30 60 51 45 39 34 30 27 24 22 19

10 58 49 41 35 31 27 23 21 18 16

INDOOR CANDELA PLOT 0 0 31 27 23 20 18 15 14 12 11 10

180

165

150

135

1300

120 650 105

90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance650

75

ENERGY DATA

60

Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

88.7% 76 Yes-VDT Normal Use $3.16 based on 3000 hrs. and $0.08 per KWH

1300 0

15

0.0

30 Horiz 0-180

45

45.0

90.0

Test Date 2/3/00

PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

SLS-2T8-LD-EB8 Solaris Architectural Curve 9" × 48" 2 LAMP WITH 1 × 11 CELL SEMISPECULAR LOUVER RCN-2P32-SC 0.88 F32T8 2900 62 Pendant 0º = 21  90º = 24 0º = 1.20  90º = 1.31 Length: 3.80 Width: 0.37 Height: 0.00

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

5711 5322 4907 4526 4026 3390 2480 1359 269 177 132 176

5711 5852 5467 5078 4562 3884 2970 1884 694 296 220 176

5711 5932 5706 5435 5300 5152 5374 4311 1947 503 353 264

5711 5994 5786 6085 6622 8209 7503 5127 1724 769 485 439

5711 5994 5876 6334 7718 9503 8590 5090 1500 828 573 439

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 611 995 1774 2005 1161 1754 2745 3385 5390

10.5 17.2 30.6 34.6 20.0 30.2 47.3 58.4 92.9

11.3 18.5 32.9 37.2 21.5 32.5 50.9 62.8 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test 12479

RC RW 1 2 3 4 5 6 7 8 9 10

70 89 81 74 68 62 57 53 49 45 42

80 50 30 85 82 75 69 66 59 58 51 52 44 46 39 42 34 38 31 34 27 31 25

10 79 65 54 46 39 34 29 26 23 20

70 80 73 67 61 56 52 48 44 41 38

70 50 30 77 74 68 63 60 54 53 47 47 41 42 36 38 32 35 28 31 25 29 23

10 72 60 50 42 36 31 27 24 21 19

50 63 55 49 43 39 35 32 29 26 24

50 30 61 52 45 39 34 30 27 24 22 19

10 59 49 42 36 31 27 23 21 18 16

INDOOR CANDELA PLOT 0 0 30 26 22 19 16 14 13 11 10 9

180

165

150

135

900

120 450 105

90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75 450 60

ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

92.9% 76 Yes-VDT Normal Use $3.16 based on 3000 hrs. and $0.08 per KWH

900 0

0.0

15

30 Horiz 0-180

45.0

Page 2/3 Rev. 11/08/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

45

90.0

Test Date 4/4/2000

CURVES / SLS

SOLARIS 1, 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

SLS-2T885/15-LD-EB8 Solaris Architectural Curve 9" × 48" 2L W/ 1X11 CELL SEMI-SPEC LOUVER & DOWNLIGHT SCREEN RCN-2P32-SC 1.00 F32T8 2900 63 Pendant 0º = 21  90º = 24 0º = 1.08  90º = 1.16 Length: 3.80 Width: 0.37 Height: 0.00

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

535 525 513 502 493 473 443 407 368 325 308 307

535 644 713 729 677 593 496 452 424 398 418 526

535 535 535 763 679 644 618 558 558 556 551 556 529 547 558 519 553 566 512 558 573 515 578 614 514 648 681 590 738 767 682 902 946 1008 1402 1534

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 273 421 636 685 1389 2142 3437 4295 4980

4.7 7.3 11.0 11.8 23.9 36.9 59.3 74.1 85.9

5.5 8.5 12.8 13.8 27.9 43.0 69.0 86.2 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test 12486

RC RW 1 2 3 4 5 6 7 8 9 10

70 77 71 64 59 54 50 46 42 39 37

80 50 30 74 71 65 60 57 51 50 44 45 38 40 34 36 30 33 26 29 24 27 21

10 68 56 47 40 34 29 25 22 19 17

70 68 62 56 51 47 43 40 37 34 32

70 50 30 65 62 57 53 50 45 44 39 40 34 35 30 32 27 29 24 26 21 24 19

10 60 50 42 35 30 26 23 20 18 16

50 48 42 37 33 30 27 24 22 20 18

50 30 46 40 34 30 26 23 20 18 16 15

10 45 37 32 27 23 20 18 16 14 12

INDOOR CANDELA PLOT 0 0 11 9 8 7 6 6 5 5 4 4

180

Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

85.9% 70 Yes-VDT Normal Use $3.43 based on 3000 hrs. and $0.08 per KWH

150

135

120 550 105

90

75

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

ENERGY DATA

165

1100

550 60

1100 0

0.0

15

30 Horiz 0-180

45.0

Page 3/3 Rev. 11/08/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

45

90.0

Test Date 4/28/00

CURVES / SLS