harbour milspec catalog

Report 51 Downloads 109 Views
Harbour I N D U S T R I E S

High Performance Wire & Cable

Founded in 1965, Harbour Industries’ vision was to fill the gap between the demand for high quality, high performance wire and cable and the supply available at the time. The military's stringent requirements for quality wire and cable shipped in a timely manner were the formative guidelines for today's Harbour. Attention to detail and a respect for the customer's needs have enabled Harbour to grow in markets that demand quality, consistency and availability. Throughout it’s history Harbour has stressed the importance of an efficient, productive manufacturing facility. A number of moves and property acquisitions have taken place, propelling Harbour to the forefront of the Mil-Spec wire and cable industry. Today Harbour boasts TFE extrusion capacity unparalleled in North America, extensive jacketing lines and high speed braiding equipment to support a wide range of lead wires; shielded and jacketed cables; and coaxial cables. Additional product lines include silicone rubber insulated mil-spec wire and cable and corresponding UL/CSA styles. Harbour’s mission statement is to remain competitive while continuing to develop processes and procedures to ensure compliance with all mil-spec wire and cable requirements. Harbour’s reputation for quality, consistency and a strong technical orientation has resulted in approvals for a variety of military constructions. Since its first day producing mil-spec wire and cable, Harbour has recognized the importance of meeting the needs of government suppliers. Today Harbour also understands the importance of maintaining this focus as many manufacturers have designed systems using mil-spec requirements independently of any government agency. This has increased the importance of ensuring the ability to produce “obsolete” specification material and transitioning to commercial versions of those items. Ultimately quality is the goal and focus of Harbour Industries. Certified to ISO-9001, Harbour’s quality system ensures that what we manufacture meets or exceeds our customer’s requirements for product quality, performance and delivery.

US 800 659 4733 800 65 WIRED Canada 450 293 5304 www.harbourind.com e-mail - [email protected]

2

Table of

Contents

Single Conductor Constructions MIL-W-16878 - Extruded TFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 M16878/4, /5, /6, /23, /25, /27 NEMA HP3 Types E, EE, ET, EN, EEN, ETN . . . . . . . . . . . . . . . . . .4 replaces M16878 MIL-W-16878 - Extruded FEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 M16878/11, /12, /13 NEMA HP4 Types K, KK, KT, KZ, KKZ, KZT . . . . . . . . . . . . . . . . . .6 replaces M16878 MIL-DTL-16878 - Wrapped TFE . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 M16878/20, /22, /24, /26, /28, /34, /35 MIL-DTL-16878 - Extruded Silicone Rubber . . . . . . . . . . . . . . . . . . .8 M16878/7, /8, /29, /30, /31, /32 MIL-W-22759 - Extruded TFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9, 10 M22759/9, /10, /11, /12, /20, /21, /22, /23 MIL-W-22759 - Mineral Filled TFE . . . . . . . . . . . . . . . . . . . . . . . . . .11 M22759/5, /6, /7, /8 MIL-W-22759 - Extruded ETFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 M22759/16, /17, /18, /19 MIL-W-81822 - Extruded TFE or ETFE . . . . . . . . . . . . . . . . . . . . . . .13 M16878/4, /5, /6, /23, /25, /27 UL and CSA Hook Up and Lead Wire Index . . . . . . . . . . . . . . . . . . . .14

Multiconductor Constructions MIL-DTL-27500 - Base Specification . . . . . . . . . . . . . . . . . . . . . . . . . .16 MIL-DTL-27500 - Type TE-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 M22759/16 Primary conductors MIL-DTL-27500 - Type TG-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 M22759/18 Primary conductors MIL-DTL-27500 - Type RC-06 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 M22759/11 Primary conductors, wrapped PTFE jacket Type STJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Commercial equivalent to Type RC-06 MIL-DTL-27500 - Type RC-09 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 M22759/11 Primary conductors, extruded FEP jacket Type SE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Commercial equivalent to Type RC-09 MIL-C-55021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 M16878/4 or M16878/5 Primary conductors MIL-C-17 Coaxial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23, 24 Buying Directory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25, 26

MIL-W-16878 Extruded TFE For Reference Only*

Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 260º C. PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment, and PTFE can be used in systems subject to current overload conditions or mechanical stress.

Similar mil-spec constructions available (call factory for details) - MIL-W-81822/6, MPD-1506

Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 30 1/30 30 7/38 28 1/28 28 7/36 28 19/40 26 1/26 26 7/34 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 18 19/30 16 19/29 14 19/27 12 19/25 10 37/26 8 133/29

M16878/4

M16878/5

M16878/6

M16878/23

600 200 SPC

1000 200 SPC

250 200 SPC

600 260 NPC

10/.030 10/.032 10/.033 10/.035 10/.036 10/.036 10/.039 10/.040 10/.040 10/.044 10/.045 10/.045 10/.050 10/.051 10/.052 10/.058 10/.058 10/.061 10/.069 10/.069 13/.080 13/.095 15/.114 13/.134 -

Insulation thickness (mils) / Overall diameter (inches) 15/.040 6/.022 10/.030 15/.042 6/.024 10/.032 15/.043 6/.025 10/.033 15/.045 6/.027 10/.035 15/.046 6/.027 10/.036 15/.046 6/.028 10/.036 15/.049 6/.031 10/.039 15/.049 6/.031 10/.040 15/.050 6/.032 10/.040 15/.054 6/.036 10/.044 15/.055 6/.036 10/.045 15/.055 6/.038 10/.045 15/.060 6/.042 10/.050 15/.061 6/.042 10/.051 15/.062 6/.044 10/.052 15/.068 6/.050 10/.058 15/.069 6/.052 10/.058 15/.071 10/.061 15/.079 10/.069 15/.080 10/.069 18/.089 13/.080 18/.106 13/.095 21/.125 15/.114 19/.145 13/.134 24/.209 -

All figures referenced are nominal.

*MIL-W-16878 is obsolete and has been replaced by NEMA HP 3 See page 4 of this catalog.

3

M16878/25

M16878/27

1000 260 NPC

250 260 NPC

15/.040 15/.042 15/.043 15/.045 15/.046 15/.046 15/.049 15/.049 15/.050 15/.054 15/.055 15/.055 15/.060 15/.061 15/.062 15/.068 15/.069 15/.071 15/.079 15/.080 18/.089 18/.106 21/.125 19/.145 24/.209

6/.022 6/.024 6/.025 6/.027 6/.027 6/.028 6/.031 6/.031 6/.032 6/.036 6/.036 6/.038 6/.042 6/.042 6/.044 6/.050 6/.052 -

NEMA HP3 Types E, EE, ET Replaces M16878

Applications For use in internal wiring of electronic equipment and appliances. Nema HP-3, TFE lead wires have a low coefficient of friction which promotes easy handling. The insulation also resists hot soldering irons, is self extinguishing, non-flammable, has excellent chemical resistance and is suitable for immersion in gasoline, gasoline vapor and at 80º C. maximum, oil. PTFE insulation is not affected by weathering, ozone, or corrosive environments.

Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 30 1/30 30 7/38 28 1/28 28 7/36 28 19/40 26 1/26 26 7/34 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 18 19/30 16 19/29 14 19/27 12 19/25 10 37/26 8 133/29

Type E

Type EE

Type ET

Type EN

600 200 SPC

1000 200 SPC

250 200 SPC

600 260 NPC

10/.030 10/.032 10/.033 10/.035 10/.036 10/.036 10/.039 10/.040 10/.040 10/.044 10/.045 10/.045 10/.050 10/.051 10/.052 10/.058 10/.058 10/.061 10/.069 10/.069 13/.080 13/.095 15/.114 13/.134 -

Insulation thickness (mils) / Overall diameter (inches) 15/.040 6/.022 10/.030 15/.042 6/.024 10/.032 15/.043 6/.025 10/.033 15/.045 6/.027 10/.035 15/.046 6/.027 10/.036 15/.046 6/.028 10/.036 15/.049 6/.031 10/.039 15/.049 6/.031 10/.040 15/.050 6/.032 10/.040 15/.054 6/.036 10/.044 15/.055 6/.036 10/.045 15/.055 6/.038 10/.045 15/.060 6/.042 10/.050 15/.061 6/.042 10/.051 15/.062 6/.044 10/.052 15/.068 6/.050 10/.058 15/.069 6/.052 10/.058 15/.071 10/.061 15/.079 10/.069 15/.079 10/.069 18/.089 13/.080 18/.106 13/.095 21/.125 15/.114 19/.145 13/.134 24/.209 -

Type EEN

Type ETN

1000 260 NPC

250 260 NPC

15/.040 15/.042 15/.043 15/.045 15/.046 15/.046 15/.049 15/.049 15/.050 15/.054 15/.055 15/.055 15/.060 15/.061 15/.062 15/.068 15/.069 15/.071 15/.079 15/.079 18/.089 18/.106 21/.125 19/.145 24/.209

6/.022 6/.024 6/.025 6/.027 6/.027 6/.028 6/.031 6/.031 6/.032 6/.036 6/.036 6/.038 6/.042 6/.042 6/.044 6/.050 6/.052 -

All figures referenced are nominal.

Products referenced on this page are manufactured with extruded PTFE insulation. Tape wrapped versions are also available, contact factory for details.

4

MIL-W-16878 Extruded FEP For Reference Only*

Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 200º C. FEP is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment, and FEP can be used in systems subject to current overload conditions or mechanical stress.

M16878/11 Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 30 1/30 30 7/38 28 1/28 28 7/36 26 1/26 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 16 1/16 16 19/29 14 1/14 14 19/27 12 19/25 10 37/26 8 133/29

M16878/12

M16878/13

600 200 SPC

1000 200 SPC

250 200 SPC

10/.030 10/.032 10/.033 10/.035 10/.036 10/.039 10/.040 10/.044 10/.044 10/.045 10/.050 10/.050 10/.052 10/.058 10/.058 10/.061 10/.069 10/.074 10/.080 12/.087 14/.095 15/.114 -

Insulation thickness (mils) / Overall diameter (inches) 15/.040 15/.042 15/.043 15/.045 15/.046 15/.049 15/.050 15/.054 15/.054 15/.055 15/.060 15/.060 15/.062 15/.068 15/.068 15/.071 15/.079 16/.083 18/.089 17/.098 20/.106 21/.125 19/.145 24/.209

6/.022 6/.024 6/.025 6/.027 6/.028 6/.031 6/.032 6/.036 6/.036 6/.038 6/.042 6/.042 6/.044 6/.050 6/.050 -

All figures referenced are nominal.

*MIL-W-16878 is obsolete and has been replaced by NEMA HP 4 See page 6 of this catalog.

5

NEMA HP4 Types K, KK, KT Replaces M16878

Applications For use in internal wiring of electronic equipment and appliances. NEMA HP4, FEP lead wires have a low coefficient of friction which promotes easy handling. The insulation also resists hot soldering irons, is self extinguishing, non-flammable, has excellent chemical resistance and is suitable for immersion in gasoline, gasoline vapor and at 80º C. maximum, oil. FEP insulation is not affected by weathering, ozone, or corrosive environments.

Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 30 1/30 30 7/38 28 1/28 28 7/36 28 19/40 26 1/26 26 7/34 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 18 19/30 16 19/29 14 19/27 12 19/25 10 37/26 8 133/29

Type K

Type KK

Type KT

Type KZ

600 200 SPC

1000 200 SPC

250 200 SPC

600 150 TPC

10/.030 10/.032 10/.033 10/.035 10/.036 10/.036 10/.039 10/.040 10/.040 10/.044 10/.045 10/.045 10/.050 10/.051 10/.052 10/.058 10/.059 10/.061 10/.069 10/.068 14/.080 14/.095 15/.114 13/.134 -

Insulation thickness (mils) / Overall diameter (inches) 15/.040 6/.022 10/.030 15/.042 6/.024 10/.032 15/.043 6/.025 10/.033 15/.045 6/.027 10/.035 15/.045 6/.027 10/.036 15/.046 6/.028 10/.036 15/.049 6/.031 10/.039 15/.049 6/.031 10/.040 15/.050 6/.032 10/.040 15/.054 6/.036 10/.044 15/.054 6/.036 10/.045 15/.055 6/.038 10/.045 15/.060 6/.042 10/.050 15/.060 6/.042 10/.051 15/.062 6/.044 10/.052 15/.068 6/.050 10/.058 15/.069 6/.052 10/.059 15/.070 10/.061 16/.079 10/.069 16/.079 10/.068 18/.089 14/.080 19/.106 14/.095 20/.125 15/.114 18/.145 13/.134 24/.209 -

Type KKZ

Type KKZT

1000 150 TPC

250 150 TPC

15/.040 15/.042 15/.043 15/.045 15/.045 15/.046 15/.049 15/.049 15/.050 15/.054 15/.054 15/.055 15/.060 15/.061 15/.052 15/.058 15/.069 10/.061 16/.078 16/.079 18/.089 19/.106 20/.125 18/.145 24/.209

6/.022 6/.024 6/.025 6/.027 6/.027 6/.028 6/.031 6/.031 6/.032 6/.036 6/.036 6/.038 6/.042 6/.042 6/.044 6/.050 6/.052 -

All figures referenced are nominal.

6

MIL-DTL-16878 Wrapped TFE For Reference Only*

Applications For use in electronic and electrical applications with ambient temperatures up to 200º C. PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment, and PTFE can be used in systems subject to current overload conditions or mechanical stress.

M16878/20

M16878/21

M16878/22

M16878/24

Voltage Rating Temperature (° C.) Conductor Type

250 200 SPC

600 200 SPC

1000 200 SPC

250 260 NPC

AWG size & stranding 30 1/30 28 1/28 28 7/36 26 1/26 26 7/34 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 18 19/30 16 1/16 16 19/29 14 19/27 12 19/25 12 37/28 12 65/30 10 37/26 8 133/29 6 133/27

6/.022 6/.025 6/.027 6/.028 6/.031 6/.031 6/.032 6/.036 6/.036 6/.037 6/.042 6/.042 6/.044 6/.050 6/.050 -

10/.030 10/.033 10/.035 10/.036 10/.039 10/.039 10/.040 10/.044 10/.044 10/.045 10/.050 10/.050 10/.052 10/.058 10/.058 11/.061 11/.069 11/.069 12/.074 14/.080 15/.095 15/.114 14/112 13/.134 -

M16878/26

M16878/28

M16878/34

M16878/35

1000 260 NPC

1000

1000

SPC

NPC

15/.045 15/.049 15/.054 15/.060 15/.068 16/.079 16/.089 17/.106 17/.125 17/.123 17/.145 20/.209 25/.263

15/.045 15/.049 15/.054 15/.060 15/.068 16/.079 16/.089 17/.106 17/.125 17/.123 17/.145 20/.209 25/.263

600 260 NPC

Insulation thickness (mils) / Overall diameter (inches) 15/.040 6/.022 10/.030 15/.040 15/.043 6/.025 10/.033 15/.043 15/.045 6/.027 10/.035 15/.045 15/.046 6/.028 10/.036 15/.046 15/.049 6/.031 10/.039 15/.049 15/.049 6/.031 10/.039 15/.049 15/.050 6/.032 10/.040 15/.050 15/.054 6/.036 10/.044 15/.054 15/.054 6/.036 10/.044 15/.054 15/.055 6/.037 10/.045 15/.055 15/.060 6/.042 10/.050 15/.060 15/.060 6/.042 10/.050 15/.060 15/.062 6/.044 10/.052 15/.062 15/.068 6/.050 10/.058 15/.068 15/.068 6/.050 10/.058 15/.068 15/.071 11/.061 15/.071 16/.079 11/.069 16/.079 16/.079 11/.069 16/.079 16/.083 12/.074 16/.083 16/.089 14/.080 16/.089 17/.106 15/.095 17/.106 17/.125 15/.114 17/.125 17/.123 14/.112 17/.123 17/.127 17/.145 13/.134 17/.145 20/.209 20/.209 25/.263 25/.263

All figures referenced are nominal.

*MIL-W-16878 is obsolete and has been replaced by NEMA HP 3

7

MIL-DTL-16878 Silicone Rubber

Applications For internal wiring of electrical equipment and where moisture, cold and/or heat may be present. Styles with fiberglass insulation offer excellent abrasion resistance.

Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 24 7/32 22 7/30 20 7/28 20 10/30 18 7/26 18 16/30 16 19/29 16 26/30 14 19/27 14 41/30 12 19/25 12 65/30 10 37/26 10 105/30 8 133/29 6 133/27 4 133/25 2 133/23 1 259/25 1/0 259/24 2/0 259/23 3/0 259/22 4/0 259/21

M16878/7

M16878/8

M16878/29

M16878/30

600 200 SPC

1000 200 SPC

600 150 TPC

1000 150 TPC

16/.055 16/.061 16/.069 16/.069 16/.079 16/.079 16/.088 16/.088 24/.119 24/.119 24/.138 24/.138 22/.161 -

Insulation thickness (mils) / Overall diameter (inches) 32/.087 16/.055 32/.087 32/.093 16/.061 32/.093 32/.101 16/.069 32/.101 32/.101 16/.069 32/.101 32/.111 16/.079 32/.111 32/.111 16/.079 32/.111 32/.120 16/.088 32/.120 32/.120 16/.088 32/.120 47/.166 24/.119 47/.166 47/.166 24/.119 47/.166 47/.185 24/.138 47/.185 47/.185 24/.138 47/.185 47/.205 47/.205 44/.205 22/.161 44/.205 63/.294 63/.294 63/.338 63/.338 63/.394 63/.394 63/.460 63/.460 78/.534 78/.534 78/.580 78/.580 78/.633 78/.633 88/.709 88/.709 78/.757 78/.757

M16878/31

M16878/32

1000 150 TPC

1000 200 SPC

35/.094 35/.100 35/.108 35/.108 35/.118 32/.111 35/.127 35/.127 52/.176 52/.176 52/.195 47/.185 52/.215 47/.205 72/.312 72/.356 73/.414 72/.478 87/.552 87/.598 87/.651 88/.709 87/.775

35/.094 35/.100 35/.108 35/.108 35/.118 32/.111 35/.127 35/.127 52/.176 52/.176 52/.195 47/.185 52/.215 47/.205 72/.312 72/.356 73/.414 72/.478 87/.552 87/.598 87/.651 88/.709 87/.775

All figures referenced are nominal.

8

MIL-W-22759 Extruded TFE

Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 260º C. PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment and can be used in systems subject to current overload conditions or mechanical stress. Identification Surface printed in accordance with MIL-W-22759

Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 28 7/36 26 19/38 24 19/36 22 19/34 20 19/32 18 19/30 16 19/29 14 19/27 12 19/25 10 37/26 8 133/29

M22759/9

M22759/10

M22759/11

M22759/12

1000 200 SPC

1000 260 NPC

600 200 SPC

600 260 NPC

Insulation thickness (mils) / Overall diameter (inches) 14/.043 14/.043 9/.033 15/.048 14/.048 10/.038 15/.053 14/.053 10/.043 15/.060 15/.060 9/.049 15/.068 15/.068 10/.058 15/.078 15/.078 10/.068 15/.085 15/.085 10/.075 16/.100 16/.100 11/.090 17/.120 17/.120 13/.111 16/.141 16/.141 15/.139 22/.207 19/.202

All figures referenced are nominal.

9

9/.033 10/.038 10/.043 9/.049 10/.058 10/.068 10/.075 11/.090 12/.111 15/.139 19/.202

MIL-W-22759 Extruded TFE

Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 260º C. PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment and can be used in systems subject to current overload conditions or mechanical stress. Identification Surface printed in accordance with MIL-W-22759

Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 28 7/36 26 19/38 24 19/36 22 19/34 20 19/32

M22759/20

M22759/21

M22759/22

M22759/23

1000 200 SPTF

1000 260 NPTF

600 200 SPTF

600 260 NPTF

Insulation thickness (mils) / Overall diameter (inches) 15/.043 14/.043 10/.033 15/.048 15/.048 10/.038 15/.053 15/.053 10/.043 16/.060 15/.060 10/.049 15/.068 15/.068 10/.058

9/.033 10/.038 10/.043 10/.049 10/.058

All figures referenced are nominal.

10

MIL-W-22759 Mineral Filled TFE

Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 260º C. Mineral filled PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment and can be used in systems subject to current overload conditions or mechanical stress. Mineral filled PTFE insulation also offers improved abrasion resistance over standard PTFE constructions. Identification Surface printed in accordance with MIL-W-22759

Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 24 19/36 22 19/34 20 19/32 18 19/30 16 19/29 14 19/27 12 19/25 10 19/26

M22759/5

M22759/6

M22759/7

M22759/8

600 200 SPC

600 260 NPC

600 200 SPC

600 260 NPC

Insulation thickness (mils) / Overall diameter (inches) 26/.075 25/.075 19/.062 28/.085 27/.085 22/.073 29/.095 28/.095 22/.082 31/.110 31/.110 22/.092 36/.125 35/.125 24/.102 38/.143 37/.143 23/.115 38/.160 37/.160 24/.134 35/.179 35/.179 25/.158

19/.062 21/.073 22/.082 22/.092 24/.102 23/.115 24/.134 24/.158

All figures referenced are nominal.

Harbour I N D U S T R I E S

High Performance Wire & Cable

11

MIL-W-22759 Extruded ETFE

Applications For use in aerospace, electronic and electrical installations with ambient or conductor temperatures up to 150º C. ETFE insulation is abrasion resistant, potable and offers excellent chemical resistance. Identification Surface printed in accordance with MIL-W-22759 Similar mil-spec constructions available (call factory for details) - MIL-W-81822/13

Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 26 19/38 24 19/36 22 19/34 20 19/32 18 19/30 16 19/29 14 19/27 12 37/28 10 37/26 8 133/29 6 133/27 4 133/25 2 665/30 1 817/30 0 1045/30 00 1330/30

M22759/16

M22759/17

M22759/18

M22759/19

600 150 TPC

600 150 SPTF

600 150 TPC

600 150 SPTF

Insulation thickness (mils) / Overall diameter (inches) 11/.040 7/.032 11/.045 11/.045 7/.036 11/.052 11/.052 7/.043 11/.060 11/.060 7/.051 12/.071 7/.061 13/.079 9/.070 13/.093 9/.085 14/.114 11/.107 15/.139 13/.134 18/.199 23/.250 27/.312 29/.388 31/.431 32/.479 44/.546 -

6/.032 6/.036 6/.043 6/.051 -

All figures referenced are nominal.

12

MIL-W-81822 Extruded TFE or ETFE Applications Designed for solderless wrap connections in electrical and electronic devices and equipment. Part number example: M81822/6-A24-9 M81822 Base Specification

/6 Cable Specification

A ConductorDesignation

22 AWG Size

9 Color Code

Conductor Designated by applicable call out as indicated by letter designator located directly before AWG size call out in part number. Designations as follows: “A” - solid silver plated copper “B” - solid silver plated oxygen free copper “C” - solid silver plated high strength, high conductivity copper alloy Insulation Extruded TFE M81822/6 Extruded ETFE M81822/13, thin wall versions designated by ”V” after AWG size call out in part number

M81822/6

M81822/13

M81822/13 “V” styles

Voltage Rating Temperature (° C.)

300 200

300 150

300 150

AWG size & stranding 30 1/30 28 1/28 26 1/26 24 1/24 22 1/22 20 1/20 18 1/18

6/.022 6.5/.026 7.5/.031 11/.042 12/.048 12/.056 13/.065

Insulation thickness (mils) / Overall diameter (inches) 5/.019 7/.026 7/.029 7/.034 7/.039 7/.046 7/.054

5/.023 5/.026 5/.030 -

All figures referenced are nominal.

Harbour I N D U S T R I E S

High Performance Wire & Cable

13

UL & CSA Hook up and Lead Wire Index Insulation Material PTFE

FEP

ETFE

PFA

UL Style

CSA Classification

1164

Class I Group A/B FT1

1180

Class I Group A/B FT1

1198

Class I Group A/B FT1

AWG Size Range

Voltage Rating (Volts)

Temperature Rating (ºC)

30-10

300

150

28-10

300

200

30-10

600

150 200

1199

Class I Group A/B FT1

28-10

600

1212

-

30-16

N.S

80

1213

Class I Group A/B FT1

30-16

N.S UL/150 CSA

105

1659

Class I Group A/B FT1

30-10

600

250

1815

-

30-10

300

250

1226

-

30-14

N.S.

80

1227

-

30-10

N.S.

105

1330

Class I Group A/B FT1

30-4/0

600

200(UL)/180(CSA)

1331

-

30-4/0

600

150

1332

Class I Group A/B FT1

30-10

300

200(UL)/180(CSA)

1333

Class I Group A/B FT1

30-10

300

150

1643

Class I Group A FT1

30-4/0

300

150

1644

Class I Group A FT1

30-4/0

600

150

1671

Class I Group A FT1

30-10

300

150

10125

Class I Group A/B FT1

24-10

300

150

10126

Class I Group A/B FT1

24-10

600

150

10109

Class I Group A/B FT1

30-10

300

200

10086

Class I Group A/B FT1

30-10

600

200

1709

Class Group A FT1

-

-

-

Class Group A FT1

-

-

-

Class Group A FT1

-

-

-

Silicone

SFF-1, 3068

SEWF-1

22-16

300

150

Rubber

SEW-1, 3122

SEW-1

22-16

300

200

SFF-2,

-

-

-

-

3069,3100,

-

-

-

150

3101, 3278

SEWF-2

18-4/0

600

SF-2, 3074,

-

-

-

-

3075, 3172,

-

-

-

-

3231

SEW-2

18-4/0

600

200

3139

Class I, Group A/B FT1

24-12

600

200

3367

Class I, Group A/B FT2

24-18

300

200

3530

Class I, Group A/B FT2

24-4/0

600

200

Ceramic &

5315

Class I, Group A/B FT1

24-10

300

250

Fiberglass

5331

Class I, Group A/B FT1

22-8

300

250

5288

Class I, Group A/B FT1

24-2

600

250

Mica &

5128

Class I, Group A/B FT1

24-2

300

450

Fiberglass

5107

Class I, Group A/B FT1

22-2

600

450

Additional UL and CSA styles are available. Call factory for more information. All figures referenced are nominal.

14

MIL-C-55021 Applications One, two or three conductor cables, shielded or unshielded covering mil-spec requirements for use as internal wiring of electrical equipment. Available in a variety of configurations, defined by the specific milspec part number referenced. Part number example: M-C-55021 / 2B E24C904-903-902STW Specification/ Revision

Base wire Specification

AWG Size

Conductor Material

Color code of 1st Wire

Color code of 2nd Wire

Color code of 3rd Wire

Type of Covering

E

24

C

904

903

902

STW

MIL-C-55021/2B

Specification/Revision Details of cable consruction as outlined in the governing mil-spec and revision level. Basic Wire Specification E = MIL-W-16878/4

EE = MIL-W-16878/5

AWG Size Per individual conductor style sheets for stranding and plating. Conductor Material C = Annealed copper

S = Copper clad steel

H = High strength copper alloy

Color code A three digit code is used to indicate the color of the wire and any identifying stripes. The first digit is the color of the insulation, the second and third digits indicate the color of the first and second stripes, where applicable. The number of color codes contained in the part number also indicates the number of conductors in the cable. In the example above there are three conductors, all of which have white insulation. The stripes on the first conductor are black and yellow, the stripes on the second conductor are black and orange and on the third they are black and red. Type of cable covering Jacket color for M55021 is white unless otherwise specified. Shields, when applied, are constructed of the same conductor materials as the base wire. F = Extruded FEP S = Shielded and unjacketed SF = Shielded and jacketed with FEP STW = Shielded and PTFE tape jacket T = PTFE tape jacket U = Unshielded and unjacketed Similar mil-spec constructions available (call factory for details) MIL-C7078, MIL-27072, MIL-47206, MIL-13929, MPD-1507

15

MIL-DTL-27500 Applications Single and multiconductor cables, shielded or unshielded covering mil-spec requirements for special purpose and power electrical cable. Available in a variety of configurations, defined by the specific part mil-spec part number referenced.

Part number example: M27500A20RC3S06 Specification Number

Identification method

AWG Size

Basic Wire Specification

Number of conductors

Shield style and material

Jacket material

M27500

A

20

RC

3

S

06

Identification methods All ID methods are in accordance with Table IIIA, IIIC, or IIID of MIL-C-27500 “A” = solid colors (Table IIIA) “B” = Solid colors (Table IIIC) with band markings (Table IIID) “ - “= All conductors white with stripes (Table IIIA)

AWG size Per individual conductor style sheets for stranding and plating

Basic Wire Specification EA E RA RB VA WA SA TA LE LH

= MIL-W-22759/1 = MIL-W-22759/2 = MIL-W-22759/3 = MIL-W-22759/4 = MIL-W-22759/5 = MIL-W-22759/6 = MIL-W-22759/7 = MIL-W-22759/8 = MIL-W-22759/9 = MIL-W-22759/10

Shield Style and Material RC RE TE TF TG TH TK TL TM TN

= MIL-W-22759/11 = MIL-W-22759/12 = MIL-W-22759/16 = MIL-W-22759/17 = MIL-W-22759/18 = MIL-W-22759/19 = MIL-W-22759/20 = MIL-W-22759/21 = MIL-W-22759/22 = MIL-W-22759/23

Single Double C R F Z M K N P

Y L

S T U

W V U

Nickel clad copper Stainless steel Silver plated high strength copper Nickel plated copper Nickel plated high strength copper Silver plated copper Tin plated copper No shield

Number of conductors 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Jacket material Single Double 01 51 03 53 04 53 05 55 06 56 07 57 09 59 10 60 11 61 12 62 14 64 15 65 16 66 17 67 18 68 20 70 21 71 00 00

Extruded PVC White polyimide braid with polyimide finisher over polyester tape Polyester braid with high temperature finish over polyester tape Extruded clear FEP PTFE tape wrap White PTFE treated glass braid over pre-sintered PTFE tape Extruded white FEP Extruded clear PVDF Polyimide/FEP tape with FEP outer surface Polyimide/FEP tape with polyimide outer surface Extruded white ETFE Extruded clear ETFE Aromatic polyimide braid with high temperature finish over pre-sintered PTFE tape Extruded white ECTFE Extruded clear ECTFE Extruded white PFA Extruded clear PFA No jacket

Similar mil-spec constructions available (call factory for details) MIL-C7078, MIL-27072, MIL-47206, MIL-13929, MPD-1507

16

MIL-DTL-27500 Type RC-06

Applications Used for aerospace flight vehicles. Primary conductors manufactured in accordance to M22759/11. Identification In accordance with MIL-C-27500 Similar mil-spec constructions available (call factory for details) - MIL-C-7078, MIL-C-27072, MIL-W47206, MIS-C-13929, MPD-1507 Part Number

Primary (AWG)

Stranding (No./AWG)

Primary OD (inches)

Shield OD (inches)

Cable OD (inches)

MS27500-26RC-1S06

26

19/38

.038

.055

.079

6

MS27500-26RC-2S06

26

19/38

.038

.092

.116

10

MS27500-26RC-3S06

26

19/38

.038

.098

.122

13

MS27500-26RC-4S06

26

19/38

.038

.108

.132

16

MS27500-24RC-1S06

24

19/36

.043

.059

.083

7

MS27500-24RC-2S06

24

19/36

.043

.102

.126

13

MS27500-24RC-3S06

24

19/36

.043

.109

.133

16

MS27500-24RC-4S06

24

19/36

.043

.120

.144

19

MS27500-22RC-1S06

22

19/34

.049

.065

.089

10

MS27500-22RC-2S06

22

19/34

.049

.114

.138

15

MS27500-22RC-3S06

22

19/34

.049

.122

.146

20

MS27500-22RC-4S06

22

19/34

.049

.135

.159

25

MS27500-20RC-1S06

20

19/32

.058

.074

.098

11

MS27500-20RC-2S06

20

19/32

.058

.132

.156

20

MS27500-20RC-3S06

20

19/32

.058

.141

.165

27

MS27500-20RC-4S06

20

19/32

.058

.156

.180

35

MS27500-18RC-1S06

18

19/30

.068

.084

.108

15

MS27500-18RC-2S06

18

19/30

.068

.152

.176

28

MS27500-18RC-3S06

18

19/30

.068

.163

.187

38

MS27500-18RC-4S06

18

19/30

.068

.181

.205

47

MS27500-16RC-1S06

16

19/29

.075

.091

.115

17

MS27500-16RC-2S06

16

19/29

.075

.166

.190

33

MS27500-16RC-3S06

16

19/29

.075

.178

.202

46

MS27500-16RC-4S06

16

19/29

.075

.198

.222

59

MS27500-14RC-1S06

14

19/27

.090

.106

.130

23

MS27500-14RC-2S06

14

19/27

.090

.196

.220

45

MS27500-14RC-3S06

14

19/27

.090

.210

.234

62

MS27500-14RC-4S06

14

19/27

.090

.234

.258

79

MS27500-12RC-1S06

12

19/25

.111

.127

.151

33

MS27500-12RC-2S06

12

19/25

.111

.238

.262

68

MS27500-12RC-3S06

12

19/25

.111

.256

.280

95

MS27500-12RC-4S06

12

19/25

.111

.289

.313

126

Cable configurations of up to 10 primaries are also available.

17

All figures referenced are nominal.

Weight (lbs.)

Type STJ Commercial equivalents to Type RC-06

Applications Electrical and electronic installations with ambient temperatures up to 200º C. and voltage requirements to 600 volts. Part Number

Primary (AWG)

Stranding (No./AWG)

Primary OD (inches)

Shield OD (inches)

Cable OD (inches)

Weight (lbs.)

1XE26-734STJ

26

7/34

.038

.055

.073

6

2XE26-734STJ

26

7/34

.038

.092

.110

10

3XE26-734STJ

26

7/34

.038

.098

.116

13

4XE26-734STJ

26

7/34

.038

.108

.126

16

1XE24-1936STJ

24

19/36

.043

.059

.077

7

2XE24-1936STJ

24

19/36

.043

.102

.120

13

3XE24-1936STJ

24

19/36

.043

.109

.127

16

4XE24-1936STJ

24

19/36

.043

.120

.138

19

1XE24-1934STJ

22

19/34

.049

.065

.083

10

2XE24-1934STJ

22

19/34

.049

.114

.132

15

3XE24-1934STJ

22

19/34

.049

.122

.140

20

4XE24-1934STJ

22

19/34

.049

.135

.153

25

1XE20-1936STJ

20

19/32

.058

.074

.092

11

2XE20-1936STJ

20

19/32

.058

.132

.150

20

3XE20-1936STJ

20

19/32

.058

.141

.159

27

4XE20-1936STJ

20

19/32

.058

.156

.174

35

1XE18-1936STJ

18

19/30

.068

.084

.102

15

2XE18-1936STJ

18

19/30

.068

.152

.176

28

3XE18-1936STJ

18

19/30

.068

.163

.187

38

4XE18-1936STJ

18

19/30

.068

.181

.205

47

1XE16-1936STJ

16

19/29

.075

.091

.109

17

2XE16-1936STJ

16

19/29

.075

.166

.190

33

3XE16-1936STJ

16

19/29

.075

.178

.202

46

4XE16-1936STJ

16

19/29

.075

.198

.222

59

1XE14-1936STJ

14

19/27

.090

.106

.124

23

2XE14-1936STJ

14

19/27

.090

.196

.220

45

3XE14-1936STJ

14

19/27

.090

.210

.234

65

4XE14-1936STJ

14

19/27

.090

.234

.258

82

1XE12-1936STJ

12

19/25

.111

.127

.145

33

2XE12-1936STJ

12

19/25

.111

.238

.262

68

3XE12-1936STJ

12

19/25

.111

.256

.280

95

4XE12-1936STJ

12

19/25

.111

.289

.313

126

Cable configurations of up to 10 primaries are also available. All figures referenced are nominal.

18

MIL-DTL-27500 Type RC-09

Applications Used for aerospace flight vehicles. Primary conductors manufactured in accordance to M22759/11. Identification In accordance with MIL-C-27500 Similar mil-spec constructions available (call factory for details) - MIL-C-7078, MIL-C-27072, MIL-W47206, MIS-C-13929, MPD-1507 Part Number

Primary (AWG)

Stranding (No./AWG)

Primary OD (inches)

Shield OD (inches)

Cable OD (inches)

Weight (lbs.)

MS27500-26RC-1S09

26

19/38

.038

.055

.073

6

MS27500-26RC-2S09

26

19/38

.038

.092

.110

10

MS27500-26RC-3S09

26

19/38

.038

.098

.116

13

MS27500-26RC-4S09

26

19/38

.038

.108

.126

16

MS27500-24RC-1S09

24

19/36

.043

.059

.077

7

MS27500-24RC-2S09

24

19/36

.043

.102

.120

13

MS27500-24RC-3S09

24

19/36

.043

.109

.127

16

MS27500-24RC-4S09

24

19/36

.043

.120

.138

19

MS27500-22RC-1S09

22

19/34

.049

.065

.083

9

MS27500-22RC-2S09

22

19/34

.049

.114

.132

14

MS27500-22RC-3S09

22

19/34

.049

.122

.140

19

MS27500-22RC-4S09

22

19/34

.049

.135

.153

24

MS27500-20RC-1S09

20

19/32

.058

.074

.092

11

MS27500-20RC-2S09

20

19/32

.058

.132

.150

19

MS27500-20RC-3S09

20

19/32

.058

.141

.159

26

MS27500-20RC-4S09

20

19/32

.058

.156

.180

35

MS27500-18RC-1S09

18

19/30

.068

.084

.102

14

MS27500-18RC-2S09

18

19/30

.068

.152

.176

27

MS27500-18RC-3S09

18

19/30

.068

.163

.187

37

MS27500-18RC-4S09

18

19/30

.068

.181

.205

47

MS27500-16RC-1S09

16

19/29

.075

.091

.109

16

MS27500-16RC-2S09

16

19/29

.075

.166

.190

32

MS27500-16RC-3S09

16

19/29

.075

.178

.202

45

MS27500-16RC-4S09

16

19/29

.075

.198

.222

59

MS27500-14RC-1S09

14

19/27

.090

.106

.124

23

MS27500-14RC-2S09

14

19/27

.090

.196

.220

45

MS27500-14RC-3S09

14

19/27

.090

.210

.234

62

MS27500-14RC-4S09

14

19/27

.090

.234

.258

79

MS27500-12RC-1S09

12

19/25

.111

.127

.145

32

MS27500-12RC-2S09

12

19/25

.111

.238

.262

65

MS27500-12RC-3S09

12

19/25

.111

.256

.280

91

MS27500-12RC-4S09

12

19/25

.111

.289

.313

123

Cable configurations of up to 10 primaries are also available.

19

All figures referenced are nominal.

Type SE Commercial equivalents to Type RC-09 Applications Electrical and electronic installations with ambient temperatures up to 200º C. and voltage requirements to 600 volts.

Part Number

Primary (AWG)

Stranding (No./AWG)

Primary OD (inches)

Shield OD (inches)

Cable OD (inches)

Weight (lbs.)

1XE24-1936SE

24

19/36

.043

.059

.079

7

2XE24-1936SE

24

19/36

.043

.102

.122

13

3XE24-1936SE

24

19/36

.043

.109

.129

16

4XE24-1936SE

24

19/36

.043

.120

.140

19

1XE22-1934SE

22

19/34

.049

.065

.085

10

2XE22-1934SE

22

19/34

.049

.114

.134

15

3XE22-1934SE

22

19/34

.049

.122

.142

20

4XE22-1934SE

22

19/34

.049

.135

.155

25

1XE20-1932SE

20

19/32

.058

.074

.094

11

2XE20-1932SE

20

19/32

.058

.132

.152

20

3XE20-1932SE

20

19/32

.058

.141

.161

27

4XE20-1932SE

20

19/32

.058

.156

.180

35

1XE18-1930SE

18

19/30

.068

.084

.104

15

2XE18-1930SE

18

19/30

.068

.152

.176

28

3XE18-1930SE

18

19/30

.068

.163

.187

38

4XE18-1930SE

18

19/30

.068

.181

.205

47

1XE16-1929SE

16

19/29

.075

.091

.111

17

2XE16-1929SE

16

19/29

.075

.166

.190

33

3XE16-1929SE

16

19/29

.075

.178

.202

46

4XE16-1929SE

16

19/29

.075

.198

.222

59

1XE14-1927SE

14

19/27

.090

.109

.129

23

2XE14-1927SE

14

19/27

.090

.196

.220

45

3XE14-1927SE

14

19/27

.090

.210

.234

65

4XE14-1927SE

14

19/27

.090

.234

.258

82

1XE12-1925SE

12

19/25

.111

.127

.147

33

2XE12-1925SE

12

19/25

.111

.238

.262

68

3XE12-1925SE

12

19/25

.111

.256

.280

95

4XE12-1925SE

12

19/25

.111

.289

.309

126

Cable configurations of up to 10 primaries are also available. All figures referenced are nominal.

20

MIL-DTL-27500 Type TE-14

Applications Used for aerospace flight vehicles. Primary conductors manufactured in accordance to M22759/16. Identification In accordance with MIL-C-27500 Part Number

Primary (AWG)

Stranding (No./AWG)

Primary OD (inches)

Shield OD (inches)

Cable OD (inches)

MS27500-24TE-1T14

24

19/36

.045

.054

.072

7

MS27500-24TE-2T14

24

19/36

.045

.095

.113

11

MS27500-24TE-3T14

24

19/36

.045

.101

.119

15

MS27500-24TE-4T14

24

19/36

.045

.110

.128

19

MS27500-22TE-1T14

22

19/34

.052

.061

.079

8

MS27500-22TE-2T14

22

19/34

.052

.109

.127

15

MS27500-22TE-3T14

22

19/34

.052

.116

.134

19

MS27500-22TE-4T14

22

19/34

.052

.127

.145

25

MS27500-20TE-1T14

20

19/32

.060

.069

.087

10

MS27500-20TE-2T14

20

19/32

.060

.125

.143

19

MS27500-20TE-3T14

20

19/32

.060

.133

.151

25

MS27500-20TE-4T14

20

19/32

.060

.146

.164

32

MS27500-18TE-1T14

18

19/30

.071

.084

.102

14

MS27500-18TE-2T14

18

19/30

.071

.145

.163

26

MS27500-18TE-3T14

18

19/30

.071

.154

.178

36

MS27500-18TE-4T14

18

19/30

.071

.170

.194

45

MS27500-16TE-1T14

16

19/29

.079

.102

.120

16

MS27500-16TE-2T14

16

19/29

.079

.157

.181

31

MS27500-16TE-3T14

16

19/29

.079

.167

.191

43

MS27500-16TE-4T14

16

19/29

.079

.184

.208

54

MS27500-14TE-1T14

14

19/27

.093

.104

.122

22

MS27500-14TE-2T14

14

19/27

.093

.185

.209

43

MS27500-14TE-3T14

14

19/27

.093

.198

.222

60

MS27500-14TE-4T14

14

19/27

.093

.218

.242

76

MS27500-12TE-1T14

12

19/28

.114

.126

.144

30

MS27500-12TE-2T14

12

19/28

.114

.229

.253

60

MS27500-12TE-3T14

12

19/28

.114

.245

.269

86

MS27500-12TE-4T14

12

19/28

.114

.271

.295

114

All figures referenced are nominal.

21

Weight (lbs.)

MIL-DTL-27500 Type TG-14 Applications Used for aerospace flight vehicles. Primary conductors manufactured in accordance to M22759/18. Identification In accordance with MIL-C-27500 Part Number

Primary (AWG)

Stranding (No./AWG)

Primary OD (inches)

Shield OD (inches)

Cable OD (inches)

Weight (lbs.)

MS27500-24TG-1T14

24

19/36

.036

.054

.072

6

MS27500-24TG-2T14

24

19/36

.036

.095

.113

9

MS27500-24TG-3T14

24

19/36

.036

.101

.119

12

MS27500-24TG-4T14

24

19/36

.036

.110

.128

15

MS27500-22TG-1T14

22

19/34

.043

.061

.079

7

MS27500-22TG-2T14

22

19/34

.043

.109

.127

12

MS27500-22TG-3T14

22

19/34

.043

.116

.134

17

MS27500-22TG-4T14

22

19/34

.043

.127

.145

20

MS27500-20TG-1T14

20

19/32

.051

.069

.087

9

MS27500-20TG-2T14

20

19/32

.051

.125

.163

18

MS27500-20TG-3T14

20

19/32

.051

.133

.178

22

MS27500-20TG-4T14

20

19/32

.051

.146

.194

27

MS27500-18TG-1T14

18

19/30

.061

.084

.102

12

MS27500-18TG-2T14

18

19/30

.061

.145

.163

23

MS27500-18TG-3T14

18

19/30

.061

.154

.178

31

MS27500-18TG-4T14

18

19/30

.061

.170

.194

40

MS27500-16TG-1T14

16

19/29

.070

.090

.108

15

MS27500-16TG-2T14

16

19/29

.070

.157

.181

28

MS27500-16TG-3T14

16

19/29

.070

.167

.191

39

MS27500-16TG-4T14

16

19/29

.070

.184

.208

72

MS27500-14TG-1T14

14

19/27

.085

.104

.122

21

MS27500-14TG-2T14

14

19/27

.085

.185

.209

40

MS27500-14TG-3T14

14

19/27

.085

.198

.222

56

MS27500-14TG-4T14

14

19/27

.085

.218

.242

72

MS27500-12TG-1T14

12

19/25

.107

.126

.144

30

MS27500-12TG-2T14

12

19/25

.107

.229

.253

59

MS27500-12TG-3T14

12

19/25

.107

.245

.269

83

MS27500-12TG-4T14

12

19/25

.107

.271

.295

111

All figures referenced are nominal.

22

Mil-C-17 Coaxial Cable QPL Approved Single braid

Double braid

Triax

Twinax

Harbour supplies a complete line of high temperature, high performance QPL approved MIL-C-17 coax cables for the military, commercial and industrial applications. The specific M17 constructions referenced are manufactured in accordance with the most recent revision of the MIL-C-17 specification. The MIL-C-17 specification defines complete physical and electrical characteristics for each M17 part number, including dimensional parameters, dielectric materials, shield construction, maximum attenuation, and VSWR levels. VSWR Sweep Testing When selecting a 50 ohm coaxial cable, constructions with VSWR requirements are recommended. Manufacturing and sweep testing cables with concern for VSWR ensures a quality cable free of spikes over the referenced frequency range. (Note the test frequencies specified in the electrical characteristics section.) Precision PTFE Dielectrics All of the high temperature, high performance coax cables listed have PTFE dielectrics with high dielectric strength and low capacitance in proportion to the dielectric constant. All PTFE dielectrics are manufactured with tolerances tighter than the MIL-C-17 specification to ensure uniformity of electrical characteristics, especially impedance, attenuation and VSWR. Tape wrapped PTFE Constructions Harbour also manufactures PTFE tape wrapped cables to a previous revision of the MIL-C-17 specification. These constructions can withstand operating temperatures up to 250° C. versus 200° C. for FEP jacketed cables. Also, PTFE tape wrapped cables are generally more flexible than their FEP jacketed counterparts. UL Approvals All of Harbour’s M17 part numbers manufactured to the MIL-C-17 specification may be ordered with UL and FT4 approvals.

23

Mil-C-17 Coaxial Cables Physical Characteristics: M17 Number

Center Conductor

PTFE Overall Minimum Operating Weight Dielectric Shield Jacket Diameter Recommended Temp. (°C) (lbs./MFT) Diameter Bend Radius

M17/60-RG142 .037” SCCS M17/93-RG178 .0120”(7/.004”)SCCS M17/93-00001 .0120”(7/.004”)SCCS

.116” .033” .033”

SPC(2) SPC SPC

M17/94-RG179 .0120”(7/.004”)SCCS M17/95-RG180 .0120”(7/.004”)SCCS M17/110-RG302 .0253”SCCS M17/111-RG303 .037”SCCS M17/113-RG316 .0201”(7/.0067”)SCCS M17/127-RG393 .094”(7/.0312”)SC M17/128-RG400 .0384”(19/.008”)SC M17/131-RG403 .0120”(7/.004”)SCCS M17/152-00001 .0201”(7/.0067”)SCCS

.063” .102” .146” .116” .060” .285” .116” .033” .060”

M17/158-00001 M17/169-00001 M17/170-00001 M17/172-00001 M17/174-00001 M17/175-00001 M17/176-00002

.037”SCCS .0120”(7/.004”)SCCS .037”(SCCS .0201”(7/.0067”)SCCS .094”(7/.0312”)SCCS .0384”(19/.008”)SC .0235”(19/.005”)SPA(2)

PTFE Tape Wrap Jacketed RG Cables RG 187 A/U .0120”(7/.004)SCCS RG 188 A/U .0201”(7/.0067)SCCS RG 195 A/U .0120”(7/.004)SCCS RG 196 A/U .0120”(7/.004)SCCS

FEP FEP PFA

.195” .071” .071”

1.0” 0.4” 0.4”

-55 +200 -55 +200 -55 +230

43.0 6.3 6.3

SPC FEP SPC FEP SPC FEP SPC FEP SPC FEP SPC(2) FEP SPC(2) FEP SPC(2) FEP(2) SPC(2) FEP

.100” .141” .202” .170” .098” .390” .195” .116” .114”

0.4” 0.7” 1.0” 0.9” 0.5” 2.0” 1.0” 0.6” 0.6”

-55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200

10.8 19.8 40.0 31.0 11.5 165.0 50.0 15.0 18.5

.116” .033” .116” .060” .285” .116” .042”

SPC(2) SPC SPC SPC SPC(2) SPC(2) SPA

FEP FEP FEP FEP FEP FEP PFA

.195” .071” .170” .098” .390” .195” .129”

1.0” 0.4” 0.9” 0.5” 2.0” 1.0” 0.6”

-55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +230

43.0 6.3 31.0 11.5 165.0 50.0 18.0

.063 .060 .102 .034

SPC SPC SPC SPC

PTFE PTFE PTFE PTFE

.100” .100” .141” .067”

0.5” 0.5” 0.7” 0.4”

-55 +250 -55 +250 -55 +250 -55 +250

10.0 11.0 18.0 6.0

Comments

M17/93-RG178 w/extended temp. range

Triaxial M17/93-RG178 Double shielded M17/113-RG316 Unswept M17/60-RG142 Unswept M17/93-RG178 Unswept M17/111-RG303 Unswept M17/113-RG316 Unswept M17/127-RG393 Unswept M17/128-RG400 Controlled impedance twinax Flexible, 250° C. rated Flexible, 250° C. rated Flexible, 250° C. rated Flexible, 250° C. rated

Electrical Characteristics: M17 Number

Impedence Capacitance Max. Operating (ohms) (pF/ft) Voltage (RMS)

M17/60-RG142 50 +/- 2 29.4 M17/93-RG178 50 +/- 2 29.4 M17/93-00001 50 +/- 2 29.4 M17/94-RG179 75 +/- 3 19.4 M17/95-RG180 95 +/- 5 16.4 M17/110-RG302 75 +/- 3 19.4 M17/111-RG303 50 +/- 2 29.4 M17/113-RG316 50 +/- 2 29.4 M17/127-RG393 50 +/- 2 29.4 M17/128-RG400 50 +/- 2 29.4 M17/131-RG403 50 +/- 2 29.4 M17/152-00001 50 +/- 2 29.4 M17/158-00001 50 +/- 2 29.4 M17/169-00001 50 +/- 2 29.4 M17/170-00001 50 +/- 2 29.4 M17/172-00001 50 +/- 2 29.4 M17/174-00001 50 +/- 2 29.4 M17/175-00001 50 +/- 2 29.4 M17/176-00002 77 +/- 7 19.0 PTFE Tape Wrap Jacketed RG Cables RG 187 A/U 75 +/- 3 19.4 RG 188 A/U 50 +/- 2 29.4 RG 195 A/U 95 +/- 5 15.4 RG 196 A/U 50 +/- 2 29.4

100 MHz

Maximum attenuation (dB/100ft) @ 400 MHz 1 GHz 3 GHz 5 GHz 10 GHz

1900 1000 1000 1200 1500 2300 1900 1200 2500 1900 1000 1200 1900 1000 1900 1200 2500 1900 1000

5.5 16.0 16.0 3.9 11.0 2.4 4.5 11.5 -

11.7 33.0 33.0 21.0 17.0 8.0 8.6 21.0 5.0 10.5 37.0 24.0 11.7 33.0 8.6 21.0 5.0 10.5 -

19.0 52.0 52.0 15.0 38.0 8.8 17.0 40.0 1.4

1200 1200 1500 1000

11.0 -

21.0 21.0 17.0 29.0

38.0 -

35.0 94.0 94.0 26.0 28.0 58.0 18.0 38.0 75.0 -

58.0

Max. Test/Cut off (Freq-GHz)

48.0 24.6 50.0 110.0 -

37.0 78.0 170.0 -

8.0/32.6 3.0 /110.8 3.0 /110.8 0.4/66.5 0.4/43.8 3.0/29.1 3.0/32.6 3.0/62.3 11.0/13.2 12.4/32.3 0.4/110.8 12.4/62.3 0.40/32.6 0.40/110.8 0.40/32.6 0.40/62.3 0.40/13.2 0.40/32.3 -

-

-

0.40/66.5 3.0/62.3 0.40/43.8 0.40/110.8

“Maximum test frequencies” are those as referenced on individual slant sheets of the MIL-C-17 specification.

24

Buying Directory MIL-C-17 COAXIAL CABLE Swept

Unswept

M16/60-RG142 M17/93-RG178 M17/93-00001 M17/94-RG179 M17/95-RG180 M17/110-RG302 M17/111-RG303 M17/113-RG316 M17/128-RG400 M17/131-RG403 M17/152-00001 M17/176-00002

M17/158-00001 M17/169-00001 M17/170-00001 M17/172-00001 M17/174-00001 M17/175-00001 Commercial Grade

RG 187 A/U RG 188 A/U RG 195 A/U RG 196 A/U RG 393 IMAX

SPECIALTY COAX Communications Network Coaxial*

CN142 CN316

CN178 CN400

CN179

*Available in single or double braid configurations with Tin Plated Copper or Silver Plated Copper Braid.

Low Loss, High Frequency Coax

LL120 LL142 LL304 LL393-1 LL393-2

SB142 SB304 SB393 SB405

SS402 SS405

Low Noise Coax

High Strength Coax

LN178 LN179 LN180

HS178 HS179 HS180

SPECIALTY INDUSTRIAL WIRES

SureformPlus Hand Formable Coax Unjacketed Jacketed

SC401 SC402 SC405

SC401FJ SC402FJ SC405FJ

SC401PJ SC402PJ SC405PJ

High Performance Foam - NEC 800, NEC 820, CMR, Halogenated, Non-Halogen, CATVR

HPF195 HPF240

HPF200 HPF400

PREMISE NETWORKING CABLES Plenum, Coaxial FEP Core

NEC 800, CMP RG-59 RG-58-Thinnet RG-6 100 Ohm Twinax

RG-62

Local Area Network Cable - PVC & Plenum Rated

Category 3 XH

Category 5e

Category 5e

Category 6

Power-limited cables - NEC725, NEC800

CL2P, CMP, MMP, FPLP, CSA, FT4, FT6 Low-Cap Mid-Cap Loop Sound and Control Signaling Ethernet Transceiver IEEE 802.3 Point-of-sale cables

US 800 659 4733 800 65 WIRED Canada 450 293 5304 www.harbourind.com [email protected]

25

INDUSTRIAL WIRE & CABLE TCGT 250°C UL AND CSA UL Style AWG Sizes Voltage 5315 #24-#2 300 5288 #24-#8 600 TGGT 250°C UL AND CSA UL Style AWG Sizes Voltage 5257 #24-#8 300 5156 #24-#2 600 MG 450°C UL and CSA UL Style AWG Sizes Voltage 5128 #22-#4 300 5107 #22-#4/0 600 SLIPSTRIP 450°C UL and CSA UL Style AWG Sizes Voltage 5360 #30-#4/0 300 5359 #30-#4/0 600 UL/CSA FEP Wires (AWM) UL/CSA AWG Voltage Temp. °C. 3135/I A/B #8-#2 600 200 3127/I A/B #8-#2 600 150 3139/I A #24-#12 600 200 3241/I A/B #24-#14 300 200 3304/n/a #22-#12 10KV 200 3239/TV-15 #24-#10 15KV 150 3239/TV-20 #24-#10 20KV 150 3239/TV-25 #24-#10 25KV 150 3239/TV-30 #24-#10 30KV 150 3239/TV-40 #24-#10 40KV 150 3239/TV-50 #24-#10 50KV 150

Flameguard - 2 hour Fire Rated Heatguard - Temperatures to 1000 º C. Hartrex - Resistant to 1000 Megrads SLAR - Nuclear robotics cable

UL and CSA LEAD WIRES PTFE STYLES UL/CSA AWG Sizes Voltage Temp. °C. 1164/1 A/B #28-#12 300 200 1180/1 A/B #28-#12 300 200 1198/1 A/B #24-#12 300 150 1199/1 A/B #24-#12 600 200 1212/1 A/B #32-#12 n/r 200 1213/1 A/B #32-#12 n/r 200 1371/1 A/B #32-#12 n/r 200 1512/1 A/B #16-#14 n/r 200 1538/1 A/B #32-#12 125 105 1584/1 A/B #30-#12 1000 200 1659/1 A/B #26-#12 600 250 1716/1 A/B #32-#12 150 1500 1815/1 A/B #32-#12 300 250 UL FEP Wires (AWM) UL/CSA AWG Sizes Voltage Temp. °C. 1226/I A/B #26-#20 n/r 80 1227/I A/B #26-#14 n/r 105 1330/I A/B #26-#4/0 600 200 1331/I A/B #26-#4/0 600 150 1332/I A/B #36-#10 300 200 1333/I A/B #26-#4/0 300 150 1371/I A/B #26-#6 n/r 105 1538/I A/B #30-#6 125 105 1716/I A/B #30-#6 150 150 ETFE Wires UL/CSA AWG Sizes Voltage Temp. °C. 1517/I A/B #24-#20 n/r 105 1586/I A/B #24-#6 n/r 105 1609/I A/B #24-#6 125 105 1610/I A/B #24-#10 n/r 105 1671/I A #30-#10 300 150 10086/I A/B #24-#10 600 200 10109/I A/B #24-#10 300 200 10125/I A/B #30-#4/0 300 150 10126/I A/B #30-#4/0 600 150

Custom designs utilizing the following components are available upon request: SOLID & STRANDED CONDUCTORS Bare Copper • Grade A Nickel • Nickel Plated Copper • Nickel Plated High Strength Copper Alloy • Nickel Plated Steel • Nickel Plated Copper Clad Steel • Silver Plated High Strength Copper Alloy • Silver Plated Copper Clad Steel • Silver Plated Copper • Tin Plated Copper • Thermocouple Alloys • Resistive Alloys • Oxygen Free Nickel Plated Copper • Oxygen Free Silver Plated Copper • Tin Overcoat Copper

SHIELD MATERIALS Nickel Plated Copper • Nickel Plated Copper Clad Steel • Silver Plated Copper • Silver Plated Copper Clad Steel • Stainless steel • Flat Braid • Round Braid • Spirally Applied Flat • Aluminum Polyester Tape • Aluminum Polyimide Tape

INSULATION & JACKETING MATERIALS Extruded Materials ETFEP • ECTFE • FRPVC • FEP • PVC • PEEK • PTFE • PVDF • PFA • TPE Polyethylene • Polyimide • Polyurethane • Silicone Rubbers Tapes Ceramic • Fiberglass • Mica • Polyester • PTFE Yarns Aramid • Ceramic • Fiberglass • K-fiber • Polyimide • Polyester • Fiberglass

The UL and CSA styles listed here represent the most commonly requested items. Harbour is approved for many more styles not listed here. If you do not see a particular style that you need call 1 800 659 4733 to check availability.

Hook-Up Wire MIL-W-16878* Revision F. PTFE Insulation

MIL-W-22759 Revision E PTFE Insulation

Extruded Insulation

Part No. NEMA HP-3 AWG Size Conductor Voltage Temp. °C. M16878/4 E #30-#10 SPC 600 200 M16878/5 EE #30-#8 SPC 1000 200 M16878/6 ET #30-#20 SPC 250 200 M16878/23 ET #30-#20 NPC 250 260 M16878/25 E #22-#12 NPC 600 260 M16878/27 EE #25-#12 NPC 1000 260 Wrapped Insulation

M16878/21 M16878/22 M16878/26 M16878/28 M16878/34 M16878/35

E EE E EE EE EE

#22-#10 #22-#6 #22-#10 #22-#6 #22-#8 #22-#8

SPC SPC NPC NPC SPC NPC

600 1000 600 1000 1000 1000

200 200 260 260 200 260

K KK KT

#26-#8 #26-#4/0 #26-#20

SPC SPC SPC

600 1000 250

200 200 200

#24-#10 #24-#4/0 #24-#10 #24-#4/0

SPC SPC TPC TPC

600 1000 600 1000

200 200 150 150

TPC SPC

1000 1000

150 200

Silicone Rubber Insulation

M16878/7 M16878/8 M16878/29 M16878/30

-

Silicone Rubber and Fiberglass Insulation

M16978/31 M16878/32

AWG Size #28-#8 #28-#12 #28-#8 #28-#12 #28-#20 #28-#20 #28-#20 #28-#20

Conductor SPC NPC SPC NPC SPTF NPTF SPTF NPTF

Voltage 1000 1000 600 600 1000 1000 600 600

Temp.°C. 200 260 200 260 200 260 200 260

Mineral Filled PTFE Insulation

M22759/5 M22759/6 M22759/7 M22759/8

#24-#10 #24-#10 #24-#10 #24-#10

SPC NPC SPC NPC

600 600 600 600

200 260 200 260

#24-#2/0 #26-#20 #26-#10 #26-#20

TPC SPA TPC SPA

600 600 600 600

150 150 150 150

ETFE Insulation

FEP Insulation

M16878/11 M16878/12 M16878/13

Part No. M22759/9 M22759/10 M22759/11 M22759/12 M22759/20 M22759/21 M22759/22 M22759/23

-

#24-#4/0 #24-#4/0

*MIL-W-16878 is obsolete and no longer active. Specification requirements for equivalent constructions are found in NEMA HP-3

In addition to the referenced Military Specifications, Harbour Industries also manufactures hook-up wire and cables to the following specifications:

Hook-Up Wires (MIL-W-) 8777, 81381, 81822, 47206

Cables (MIL-C-) 7078, 27072, 55021/2B

Other MPD-1506, MPD-1507, MIS-13928, MIS-13929

M22759/16 M22759/17 M22759/18 M22759/19

MILITARY/COMMERCIAL CABLES Shielded or unshielded, extruded FEP, ETFE or tape wrapped PTFE jackets using the following components: MIL-C-27500 PTFE Insulated Primaries Symbol Primaries LE M22759/9 LH M22759/10 RC M22759/11 RE M22759/12 TK M22759/20 TM M22759/22 TN M22759/23

AWG Size #28-#8 #28-#12 #28-#8 #28-#12 #28-#20 #28-#20 #28-#20

ETFE Insulated Primaries TE M22759/16 TF M22759/17 TG M22759/18 TH M22759/19

#26-#2/0 #26-#20 #26-#10 #26-#20

Commercial Cables SE FEP Extruded Jacket STJ PTFE Wrapped Jacket

Harbour Industries, Inc. makes every effort to ensure the accuracy of the information contained in this publication. However, Harbour is not responsible for errors or changes.

US 800 659 4733 800 65 WIRED Canada 450 293 5304 www.harbourind.com e-mail - [email protected]

Harbour I N D U S T R I E S

High Performance Wire & Cable

26