Harbour I N D U S T R I E S
High Performance Wire & Cable
Founded in 1965, Harbour Industries’ vision was to fill the gap between the demand for high quality, high performance wire and cable and the supply available at the time. The military's stringent requirements for quality wire and cable shipped in a timely manner were the formative guidelines for today's Harbour. Attention to detail and a respect for the customer's needs have enabled Harbour to grow in markets that demand quality, consistency and availability. Throughout it’s history Harbour has stressed the importance of an efficient, productive manufacturing facility. A number of moves and property acquisitions have taken place, propelling Harbour to the forefront of the Mil-Spec wire and cable industry. Today Harbour boasts TFE extrusion capacity unparalleled in North America, extensive jacketing lines and high speed braiding equipment to support a wide range of lead wires; shielded and jacketed cables; and coaxial cables. Additional product lines include silicone rubber insulated mil-spec wire and cable and corresponding UL/CSA styles. Harbour’s mission statement is to remain competitive while continuing to develop processes and procedures to ensure compliance with all mil-spec wire and cable requirements. Harbour’s reputation for quality, consistency and a strong technical orientation has resulted in approvals for a variety of military constructions. Since its first day producing mil-spec wire and cable, Harbour has recognized the importance of meeting the needs of government suppliers. Today Harbour also understands the importance of maintaining this focus as many manufacturers have designed systems using mil-spec requirements independently of any government agency. This has increased the importance of ensuring the ability to produce “obsolete” specification material and transitioning to commercial versions of those items. Ultimately quality is the goal and focus of Harbour Industries. Certified to ISO-9001, Harbour’s quality system ensures that what we manufacture meets or exceeds our customer’s requirements for product quality, performance and delivery.
US 800 659 4733 800 65 WIRED Canada 450 293 5304 www.harbourind.com e-mail -
[email protected] 2
Table of
Contents
Single Conductor Constructions MIL-W-16878 - Extruded TFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 M16878/4, /5, /6, /23, /25, /27 NEMA HP3 Types E, EE, ET, EN, EEN, ETN . . . . . . . . . . . . . . . . . .4 replaces M16878 MIL-W-16878 - Extruded FEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 M16878/11, /12, /13 NEMA HP4 Types K, KK, KT, KZ, KKZ, KZT . . . . . . . . . . . . . . . . . .6 replaces M16878 MIL-DTL-16878 - Wrapped TFE . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 M16878/20, /22, /24, /26, /28, /34, /35 MIL-DTL-16878 - Extruded Silicone Rubber . . . . . . . . . . . . . . . . . . .8 M16878/7, /8, /29, /30, /31, /32 MIL-W-22759 - Extruded TFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9, 10 M22759/9, /10, /11, /12, /20, /21, /22, /23 MIL-W-22759 - Mineral Filled TFE . . . . . . . . . . . . . . . . . . . . . . . . . .11 M22759/5, /6, /7, /8 MIL-W-22759 - Extruded ETFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 M22759/16, /17, /18, /19 MIL-W-81822 - Extruded TFE or ETFE . . . . . . . . . . . . . . . . . . . . . . .13 M16878/4, /5, /6, /23, /25, /27 UL and CSA Hook Up and Lead Wire Index . . . . . . . . . . . . . . . . . . . .14
Multiconductor Constructions MIL-DTL-27500 - Base Specification . . . . . . . . . . . . . . . . . . . . . . . . . .16 MIL-DTL-27500 - Type TE-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 M22759/16 Primary conductors MIL-DTL-27500 - Type TG-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 M22759/18 Primary conductors MIL-DTL-27500 - Type RC-06 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 M22759/11 Primary conductors, wrapped PTFE jacket Type STJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Commercial equivalent to Type RC-06 MIL-DTL-27500 - Type RC-09 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 M22759/11 Primary conductors, extruded FEP jacket Type SE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Commercial equivalent to Type RC-09 MIL-C-55021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 M16878/4 or M16878/5 Primary conductors MIL-C-17 Coaxial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23, 24 Buying Directory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25, 26
MIL-W-16878 Extruded TFE For Reference Only*
Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 260º C. PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment, and PTFE can be used in systems subject to current overload conditions or mechanical stress.
Similar mil-spec constructions available (call factory for details) - MIL-W-81822/6, MPD-1506
Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 30 1/30 30 7/38 28 1/28 28 7/36 28 19/40 26 1/26 26 7/34 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 18 19/30 16 19/29 14 19/27 12 19/25 10 37/26 8 133/29
M16878/4
M16878/5
M16878/6
M16878/23
600 200 SPC
1000 200 SPC
250 200 SPC
600 260 NPC
10/.030 10/.032 10/.033 10/.035 10/.036 10/.036 10/.039 10/.040 10/.040 10/.044 10/.045 10/.045 10/.050 10/.051 10/.052 10/.058 10/.058 10/.061 10/.069 10/.069 13/.080 13/.095 15/.114 13/.134 -
Insulation thickness (mils) / Overall diameter (inches) 15/.040 6/.022 10/.030 15/.042 6/.024 10/.032 15/.043 6/.025 10/.033 15/.045 6/.027 10/.035 15/.046 6/.027 10/.036 15/.046 6/.028 10/.036 15/.049 6/.031 10/.039 15/.049 6/.031 10/.040 15/.050 6/.032 10/.040 15/.054 6/.036 10/.044 15/.055 6/.036 10/.045 15/.055 6/.038 10/.045 15/.060 6/.042 10/.050 15/.061 6/.042 10/.051 15/.062 6/.044 10/.052 15/.068 6/.050 10/.058 15/.069 6/.052 10/.058 15/.071 10/.061 15/.079 10/.069 15/.080 10/.069 18/.089 13/.080 18/.106 13/.095 21/.125 15/.114 19/.145 13/.134 24/.209 -
All figures referenced are nominal.
*MIL-W-16878 is obsolete and has been replaced by NEMA HP 3 See page 4 of this catalog.
3
M16878/25
M16878/27
1000 260 NPC
250 260 NPC
15/.040 15/.042 15/.043 15/.045 15/.046 15/.046 15/.049 15/.049 15/.050 15/.054 15/.055 15/.055 15/.060 15/.061 15/.062 15/.068 15/.069 15/.071 15/.079 15/.080 18/.089 18/.106 21/.125 19/.145 24/.209
6/.022 6/.024 6/.025 6/.027 6/.027 6/.028 6/.031 6/.031 6/.032 6/.036 6/.036 6/.038 6/.042 6/.042 6/.044 6/.050 6/.052 -
NEMA HP3 Types E, EE, ET Replaces M16878
Applications For use in internal wiring of electronic equipment and appliances. Nema HP-3, TFE lead wires have a low coefficient of friction which promotes easy handling. The insulation also resists hot soldering irons, is self extinguishing, non-flammable, has excellent chemical resistance and is suitable for immersion in gasoline, gasoline vapor and at 80º C. maximum, oil. PTFE insulation is not affected by weathering, ozone, or corrosive environments.
Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 30 1/30 30 7/38 28 1/28 28 7/36 28 19/40 26 1/26 26 7/34 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 18 19/30 16 19/29 14 19/27 12 19/25 10 37/26 8 133/29
Type E
Type EE
Type ET
Type EN
600 200 SPC
1000 200 SPC
250 200 SPC
600 260 NPC
10/.030 10/.032 10/.033 10/.035 10/.036 10/.036 10/.039 10/.040 10/.040 10/.044 10/.045 10/.045 10/.050 10/.051 10/.052 10/.058 10/.058 10/.061 10/.069 10/.069 13/.080 13/.095 15/.114 13/.134 -
Insulation thickness (mils) / Overall diameter (inches) 15/.040 6/.022 10/.030 15/.042 6/.024 10/.032 15/.043 6/.025 10/.033 15/.045 6/.027 10/.035 15/.046 6/.027 10/.036 15/.046 6/.028 10/.036 15/.049 6/.031 10/.039 15/.049 6/.031 10/.040 15/.050 6/.032 10/.040 15/.054 6/.036 10/.044 15/.055 6/.036 10/.045 15/.055 6/.038 10/.045 15/.060 6/.042 10/.050 15/.061 6/.042 10/.051 15/.062 6/.044 10/.052 15/.068 6/.050 10/.058 15/.069 6/.052 10/.058 15/.071 10/.061 15/.079 10/.069 15/.079 10/.069 18/.089 13/.080 18/.106 13/.095 21/.125 15/.114 19/.145 13/.134 24/.209 -
Type EEN
Type ETN
1000 260 NPC
250 260 NPC
15/.040 15/.042 15/.043 15/.045 15/.046 15/.046 15/.049 15/.049 15/.050 15/.054 15/.055 15/.055 15/.060 15/.061 15/.062 15/.068 15/.069 15/.071 15/.079 15/.079 18/.089 18/.106 21/.125 19/.145 24/.209
6/.022 6/.024 6/.025 6/.027 6/.027 6/.028 6/.031 6/.031 6/.032 6/.036 6/.036 6/.038 6/.042 6/.042 6/.044 6/.050 6/.052 -
All figures referenced are nominal.
Products referenced on this page are manufactured with extruded PTFE insulation. Tape wrapped versions are also available, contact factory for details.
4
MIL-W-16878 Extruded FEP For Reference Only*
Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 200º C. FEP is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment, and FEP can be used in systems subject to current overload conditions or mechanical stress.
M16878/11 Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 30 1/30 30 7/38 28 1/28 28 7/36 26 1/26 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 16 1/16 16 19/29 14 1/14 14 19/27 12 19/25 10 37/26 8 133/29
M16878/12
M16878/13
600 200 SPC
1000 200 SPC
250 200 SPC
10/.030 10/.032 10/.033 10/.035 10/.036 10/.039 10/.040 10/.044 10/.044 10/.045 10/.050 10/.050 10/.052 10/.058 10/.058 10/.061 10/.069 10/.074 10/.080 12/.087 14/.095 15/.114 -
Insulation thickness (mils) / Overall diameter (inches) 15/.040 15/.042 15/.043 15/.045 15/.046 15/.049 15/.050 15/.054 15/.054 15/.055 15/.060 15/.060 15/.062 15/.068 15/.068 15/.071 15/.079 16/.083 18/.089 17/.098 20/.106 21/.125 19/.145 24/.209
6/.022 6/.024 6/.025 6/.027 6/.028 6/.031 6/.032 6/.036 6/.036 6/.038 6/.042 6/.042 6/.044 6/.050 6/.050 -
All figures referenced are nominal.
*MIL-W-16878 is obsolete and has been replaced by NEMA HP 4 See page 6 of this catalog.
5
NEMA HP4 Types K, KK, KT Replaces M16878
Applications For use in internal wiring of electronic equipment and appliances. NEMA HP4, FEP lead wires have a low coefficient of friction which promotes easy handling. The insulation also resists hot soldering irons, is self extinguishing, non-flammable, has excellent chemical resistance and is suitable for immersion in gasoline, gasoline vapor and at 80º C. maximum, oil. FEP insulation is not affected by weathering, ozone, or corrosive environments.
Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 30 1/30 30 7/38 28 1/28 28 7/36 28 19/40 26 1/26 26 7/34 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 18 19/30 16 19/29 14 19/27 12 19/25 10 37/26 8 133/29
Type K
Type KK
Type KT
Type KZ
600 200 SPC
1000 200 SPC
250 200 SPC
600 150 TPC
10/.030 10/.032 10/.033 10/.035 10/.036 10/.036 10/.039 10/.040 10/.040 10/.044 10/.045 10/.045 10/.050 10/.051 10/.052 10/.058 10/.059 10/.061 10/.069 10/.068 14/.080 14/.095 15/.114 13/.134 -
Insulation thickness (mils) / Overall diameter (inches) 15/.040 6/.022 10/.030 15/.042 6/.024 10/.032 15/.043 6/.025 10/.033 15/.045 6/.027 10/.035 15/.045 6/.027 10/.036 15/.046 6/.028 10/.036 15/.049 6/.031 10/.039 15/.049 6/.031 10/.040 15/.050 6/.032 10/.040 15/.054 6/.036 10/.044 15/.054 6/.036 10/.045 15/.055 6/.038 10/.045 15/.060 6/.042 10/.050 15/.060 6/.042 10/.051 15/.062 6/.044 10/.052 15/.068 6/.050 10/.058 15/.069 6/.052 10/.059 15/.070 10/.061 16/.079 10/.069 16/.079 10/.068 18/.089 14/.080 19/.106 14/.095 20/.125 15/.114 18/.145 13/.134 24/.209 -
Type KKZ
Type KKZT
1000 150 TPC
250 150 TPC
15/.040 15/.042 15/.043 15/.045 15/.045 15/.046 15/.049 15/.049 15/.050 15/.054 15/.054 15/.055 15/.060 15/.061 15/.052 15/.058 15/.069 10/.061 16/.078 16/.079 18/.089 19/.106 20/.125 18/.145 24/.209
6/.022 6/.024 6/.025 6/.027 6/.027 6/.028 6/.031 6/.031 6/.032 6/.036 6/.036 6/.038 6/.042 6/.042 6/.044 6/.050 6/.052 -
All figures referenced are nominal.
6
MIL-DTL-16878 Wrapped TFE For Reference Only*
Applications For use in electronic and electrical applications with ambient temperatures up to 200º C. PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment, and PTFE can be used in systems subject to current overload conditions or mechanical stress.
M16878/20
M16878/21
M16878/22
M16878/24
Voltage Rating Temperature (° C.) Conductor Type
250 200 SPC
600 200 SPC
1000 200 SPC
250 260 NPC
AWG size & stranding 30 1/30 28 1/28 28 7/36 26 1/26 26 7/34 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 18 19/30 16 1/16 16 19/29 14 19/27 12 19/25 12 37/28 12 65/30 10 37/26 8 133/29 6 133/27
6/.022 6/.025 6/.027 6/.028 6/.031 6/.031 6/.032 6/.036 6/.036 6/.037 6/.042 6/.042 6/.044 6/.050 6/.050 -
10/.030 10/.033 10/.035 10/.036 10/.039 10/.039 10/.040 10/.044 10/.044 10/.045 10/.050 10/.050 10/.052 10/.058 10/.058 11/.061 11/.069 11/.069 12/.074 14/.080 15/.095 15/.114 14/112 13/.134 -
M16878/26
M16878/28
M16878/34
M16878/35
1000 260 NPC
1000
1000
SPC
NPC
15/.045 15/.049 15/.054 15/.060 15/.068 16/.079 16/.089 17/.106 17/.125 17/.123 17/.145 20/.209 25/.263
15/.045 15/.049 15/.054 15/.060 15/.068 16/.079 16/.089 17/.106 17/.125 17/.123 17/.145 20/.209 25/.263
600 260 NPC
Insulation thickness (mils) / Overall diameter (inches) 15/.040 6/.022 10/.030 15/.040 15/.043 6/.025 10/.033 15/.043 15/.045 6/.027 10/.035 15/.045 15/.046 6/.028 10/.036 15/.046 15/.049 6/.031 10/.039 15/.049 15/.049 6/.031 10/.039 15/.049 15/.050 6/.032 10/.040 15/.050 15/.054 6/.036 10/.044 15/.054 15/.054 6/.036 10/.044 15/.054 15/.055 6/.037 10/.045 15/.055 15/.060 6/.042 10/.050 15/.060 15/.060 6/.042 10/.050 15/.060 15/.062 6/.044 10/.052 15/.062 15/.068 6/.050 10/.058 15/.068 15/.068 6/.050 10/.058 15/.068 15/.071 11/.061 15/.071 16/.079 11/.069 16/.079 16/.079 11/.069 16/.079 16/.083 12/.074 16/.083 16/.089 14/.080 16/.089 17/.106 15/.095 17/.106 17/.125 15/.114 17/.125 17/.123 14/.112 17/.123 17/.127 17/.145 13/.134 17/.145 20/.209 20/.209 25/.263 25/.263
All figures referenced are nominal.
*MIL-W-16878 is obsolete and has been replaced by NEMA HP 3
7
MIL-DTL-16878 Silicone Rubber
Applications For internal wiring of electrical equipment and where moisture, cold and/or heat may be present. Styles with fiberglass insulation offer excellent abrasion resistance.
Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 24 7/32 22 7/30 20 7/28 20 10/30 18 7/26 18 16/30 16 19/29 16 26/30 14 19/27 14 41/30 12 19/25 12 65/30 10 37/26 10 105/30 8 133/29 6 133/27 4 133/25 2 133/23 1 259/25 1/0 259/24 2/0 259/23 3/0 259/22 4/0 259/21
M16878/7
M16878/8
M16878/29
M16878/30
600 200 SPC
1000 200 SPC
600 150 TPC
1000 150 TPC
16/.055 16/.061 16/.069 16/.069 16/.079 16/.079 16/.088 16/.088 24/.119 24/.119 24/.138 24/.138 22/.161 -
Insulation thickness (mils) / Overall diameter (inches) 32/.087 16/.055 32/.087 32/.093 16/.061 32/.093 32/.101 16/.069 32/.101 32/.101 16/.069 32/.101 32/.111 16/.079 32/.111 32/.111 16/.079 32/.111 32/.120 16/.088 32/.120 32/.120 16/.088 32/.120 47/.166 24/.119 47/.166 47/.166 24/.119 47/.166 47/.185 24/.138 47/.185 47/.185 24/.138 47/.185 47/.205 47/.205 44/.205 22/.161 44/.205 63/.294 63/.294 63/.338 63/.338 63/.394 63/.394 63/.460 63/.460 78/.534 78/.534 78/.580 78/.580 78/.633 78/.633 88/.709 88/.709 78/.757 78/.757
M16878/31
M16878/32
1000 150 TPC
1000 200 SPC
35/.094 35/.100 35/.108 35/.108 35/.118 32/.111 35/.127 35/.127 52/.176 52/.176 52/.195 47/.185 52/.215 47/.205 72/.312 72/.356 73/.414 72/.478 87/.552 87/.598 87/.651 88/.709 87/.775
35/.094 35/.100 35/.108 35/.108 35/.118 32/.111 35/.127 35/.127 52/.176 52/.176 52/.195 47/.185 52/.215 47/.205 72/.312 72/.356 73/.414 72/.478 87/.552 87/.598 87/.651 88/.709 87/.775
All figures referenced are nominal.
8
MIL-W-22759 Extruded TFE
Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 260º C. PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment and can be used in systems subject to current overload conditions or mechanical stress. Identification Surface printed in accordance with MIL-W-22759
Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 28 7/36 26 19/38 24 19/36 22 19/34 20 19/32 18 19/30 16 19/29 14 19/27 12 19/25 10 37/26 8 133/29
M22759/9
M22759/10
M22759/11
M22759/12
1000 200 SPC
1000 260 NPC
600 200 SPC
600 260 NPC
Insulation thickness (mils) / Overall diameter (inches) 14/.043 14/.043 9/.033 15/.048 14/.048 10/.038 15/.053 14/.053 10/.043 15/.060 15/.060 9/.049 15/.068 15/.068 10/.058 15/.078 15/.078 10/.068 15/.085 15/.085 10/.075 16/.100 16/.100 11/.090 17/.120 17/.120 13/.111 16/.141 16/.141 15/.139 22/.207 19/.202
All figures referenced are nominal.
9
9/.033 10/.038 10/.043 9/.049 10/.058 10/.068 10/.075 11/.090 12/.111 15/.139 19/.202
MIL-W-22759 Extruded TFE
Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 260º C. PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment and can be used in systems subject to current overload conditions or mechanical stress. Identification Surface printed in accordance with MIL-W-22759
Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 28 7/36 26 19/38 24 19/36 22 19/34 20 19/32
M22759/20
M22759/21
M22759/22
M22759/23
1000 200 SPTF
1000 260 NPTF
600 200 SPTF
600 260 NPTF
Insulation thickness (mils) / Overall diameter (inches) 15/.043 14/.043 10/.033 15/.048 15/.048 10/.038 15/.053 15/.053 10/.043 16/.060 15/.060 10/.049 15/.068 15/.068 10/.058
9/.033 10/.038 10/.043 10/.049 10/.058
All figures referenced are nominal.
10
MIL-W-22759 Mineral Filled TFE
Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 260º C. Mineral filled PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment and can be used in systems subject to current overload conditions or mechanical stress. Mineral filled PTFE insulation also offers improved abrasion resistance over standard PTFE constructions. Identification Surface printed in accordance with MIL-W-22759
Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 24 19/36 22 19/34 20 19/32 18 19/30 16 19/29 14 19/27 12 19/25 10 19/26
M22759/5
M22759/6
M22759/7
M22759/8
600 200 SPC
600 260 NPC
600 200 SPC
600 260 NPC
Insulation thickness (mils) / Overall diameter (inches) 26/.075 25/.075 19/.062 28/.085 27/.085 22/.073 29/.095 28/.095 22/.082 31/.110 31/.110 22/.092 36/.125 35/.125 24/.102 38/.143 37/.143 23/.115 38/.160 37/.160 24/.134 35/.179 35/.179 25/.158
19/.062 21/.073 22/.082 22/.092 24/.102 23/.115 24/.134 24/.158
All figures referenced are nominal.
Harbour I N D U S T R I E S
High Performance Wire & Cable
11
MIL-W-22759 Extruded ETFE
Applications For use in aerospace, electronic and electrical installations with ambient or conductor temperatures up to 150º C. ETFE insulation is abrasion resistant, potable and offers excellent chemical resistance. Identification Surface printed in accordance with MIL-W-22759 Similar mil-spec constructions available (call factory for details) - MIL-W-81822/13
Voltage Rating Temperature (° C.) Conductor Type AWG size & stranding 26 19/38 24 19/36 22 19/34 20 19/32 18 19/30 16 19/29 14 19/27 12 37/28 10 37/26 8 133/29 6 133/27 4 133/25 2 665/30 1 817/30 0 1045/30 00 1330/30
M22759/16
M22759/17
M22759/18
M22759/19
600 150 TPC
600 150 SPTF
600 150 TPC
600 150 SPTF
Insulation thickness (mils) / Overall diameter (inches) 11/.040 7/.032 11/.045 11/.045 7/.036 11/.052 11/.052 7/.043 11/.060 11/.060 7/.051 12/.071 7/.061 13/.079 9/.070 13/.093 9/.085 14/.114 11/.107 15/.139 13/.134 18/.199 23/.250 27/.312 29/.388 31/.431 32/.479 44/.546 -
6/.032 6/.036 6/.043 6/.051 -
All figures referenced are nominal.
12
MIL-W-81822 Extruded TFE or ETFE Applications Designed for solderless wrap connections in electrical and electronic devices and equipment. Part number example: M81822/6-A24-9 M81822 Base Specification
/6 Cable Specification
A ConductorDesignation
22 AWG Size
9 Color Code
Conductor Designated by applicable call out as indicated by letter designator located directly before AWG size call out in part number. Designations as follows: “A” - solid silver plated copper “B” - solid silver plated oxygen free copper “C” - solid silver plated high strength, high conductivity copper alloy Insulation Extruded TFE M81822/6 Extruded ETFE M81822/13, thin wall versions designated by ”V” after AWG size call out in part number
M81822/6
M81822/13
M81822/13 “V” styles
Voltage Rating Temperature (° C.)
300 200
300 150
300 150
AWG size & stranding 30 1/30 28 1/28 26 1/26 24 1/24 22 1/22 20 1/20 18 1/18
6/.022 6.5/.026 7.5/.031 11/.042 12/.048 12/.056 13/.065
Insulation thickness (mils) / Overall diameter (inches) 5/.019 7/.026 7/.029 7/.034 7/.039 7/.046 7/.054
5/.023 5/.026 5/.030 -
All figures referenced are nominal.
Harbour I N D U S T R I E S
High Performance Wire & Cable
13
UL & CSA Hook up and Lead Wire Index Insulation Material PTFE
FEP
ETFE
PFA
UL Style
CSA Classification
1164
Class I Group A/B FT1
1180
Class I Group A/B FT1
1198
Class I Group A/B FT1
AWG Size Range
Voltage Rating (Volts)
Temperature Rating (ºC)
30-10
300
150
28-10
300
200
30-10
600
150 200
1199
Class I Group A/B FT1
28-10
600
1212
-
30-16
N.S
80
1213
Class I Group A/B FT1
30-16
N.S UL/150 CSA
105
1659
Class I Group A/B FT1
30-10
600
250
1815
-
30-10
300
250
1226
-
30-14
N.S.
80
1227
-
30-10
N.S.
105
1330
Class I Group A/B FT1
30-4/0
600
200(UL)/180(CSA)
1331
-
30-4/0
600
150
1332
Class I Group A/B FT1
30-10
300
200(UL)/180(CSA)
1333
Class I Group A/B FT1
30-10
300
150
1643
Class I Group A FT1
30-4/0
300
150
1644
Class I Group A FT1
30-4/0
600
150
1671
Class I Group A FT1
30-10
300
150
10125
Class I Group A/B FT1
24-10
300
150
10126
Class I Group A/B FT1
24-10
600
150
10109
Class I Group A/B FT1
30-10
300
200
10086
Class I Group A/B FT1
30-10
600
200
1709
Class Group A FT1
-
-
-
Class Group A FT1
-
-
-
Class Group A FT1
-
-
-
Silicone
SFF-1, 3068
SEWF-1
22-16
300
150
Rubber
SEW-1, 3122
SEW-1
22-16
300
200
SFF-2,
-
-
-
-
3069,3100,
-
-
-
150
3101, 3278
SEWF-2
18-4/0
600
SF-2, 3074,
-
-
-
-
3075, 3172,
-
-
-
-
3231
SEW-2
18-4/0
600
200
3139
Class I, Group A/B FT1
24-12
600
200
3367
Class I, Group A/B FT2
24-18
300
200
3530
Class I, Group A/B FT2
24-4/0
600
200
Ceramic &
5315
Class I, Group A/B FT1
24-10
300
250
Fiberglass
5331
Class I, Group A/B FT1
22-8
300
250
5288
Class I, Group A/B FT1
24-2
600
250
Mica &
5128
Class I, Group A/B FT1
24-2
300
450
Fiberglass
5107
Class I, Group A/B FT1
22-2
600
450
Additional UL and CSA styles are available. Call factory for more information. All figures referenced are nominal.
14
MIL-C-55021 Applications One, two or three conductor cables, shielded or unshielded covering mil-spec requirements for use as internal wiring of electrical equipment. Available in a variety of configurations, defined by the specific milspec part number referenced. Part number example: M-C-55021 / 2B E24C904-903-902STW Specification/ Revision
Base wire Specification
AWG Size
Conductor Material
Color code of 1st Wire
Color code of 2nd Wire
Color code of 3rd Wire
Type of Covering
E
24
C
904
903
902
STW
MIL-C-55021/2B
Specification/Revision Details of cable consruction as outlined in the governing mil-spec and revision level. Basic Wire Specification E = MIL-W-16878/4
EE = MIL-W-16878/5
AWG Size Per individual conductor style sheets for stranding and plating. Conductor Material C = Annealed copper
S = Copper clad steel
H = High strength copper alloy
Color code A three digit code is used to indicate the color of the wire and any identifying stripes. The first digit is the color of the insulation, the second and third digits indicate the color of the first and second stripes, where applicable. The number of color codes contained in the part number also indicates the number of conductors in the cable. In the example above there are three conductors, all of which have white insulation. The stripes on the first conductor are black and yellow, the stripes on the second conductor are black and orange and on the third they are black and red. Type of cable covering Jacket color for M55021 is white unless otherwise specified. Shields, when applied, are constructed of the same conductor materials as the base wire. F = Extruded FEP S = Shielded and unjacketed SF = Shielded and jacketed with FEP STW = Shielded and PTFE tape jacket T = PTFE tape jacket U = Unshielded and unjacketed Similar mil-spec constructions available (call factory for details) MIL-C7078, MIL-27072, MIL-47206, MIL-13929, MPD-1507
15
MIL-DTL-27500 Applications Single and multiconductor cables, shielded or unshielded covering mil-spec requirements for special purpose and power electrical cable. Available in a variety of configurations, defined by the specific part mil-spec part number referenced.
Part number example: M27500A20RC3S06 Specification Number
Identification method
AWG Size
Basic Wire Specification
Number of conductors
Shield style and material
Jacket material
M27500
A
20
RC
3
S
06
Identification methods All ID methods are in accordance with Table IIIA, IIIC, or IIID of MIL-C-27500 “A” = solid colors (Table IIIA) “B” = Solid colors (Table IIIC) with band markings (Table IIID) “ - “= All conductors white with stripes (Table IIIA)
AWG size Per individual conductor style sheets for stranding and plating
Basic Wire Specification EA E RA RB VA WA SA TA LE LH
= MIL-W-22759/1 = MIL-W-22759/2 = MIL-W-22759/3 = MIL-W-22759/4 = MIL-W-22759/5 = MIL-W-22759/6 = MIL-W-22759/7 = MIL-W-22759/8 = MIL-W-22759/9 = MIL-W-22759/10
Shield Style and Material RC RE TE TF TG TH TK TL TM TN
= MIL-W-22759/11 = MIL-W-22759/12 = MIL-W-22759/16 = MIL-W-22759/17 = MIL-W-22759/18 = MIL-W-22759/19 = MIL-W-22759/20 = MIL-W-22759/21 = MIL-W-22759/22 = MIL-W-22759/23
Single Double C R F Z M K N P
Y L
S T U
W V U
Nickel clad copper Stainless steel Silver plated high strength copper Nickel plated copper Nickel plated high strength copper Silver plated copper Tin plated copper No shield
Number of conductors 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Jacket material Single Double 01 51 03 53 04 53 05 55 06 56 07 57 09 59 10 60 11 61 12 62 14 64 15 65 16 66 17 67 18 68 20 70 21 71 00 00
Extruded PVC White polyimide braid with polyimide finisher over polyester tape Polyester braid with high temperature finish over polyester tape Extruded clear FEP PTFE tape wrap White PTFE treated glass braid over pre-sintered PTFE tape Extruded white FEP Extruded clear PVDF Polyimide/FEP tape with FEP outer surface Polyimide/FEP tape with polyimide outer surface Extruded white ETFE Extruded clear ETFE Aromatic polyimide braid with high temperature finish over pre-sintered PTFE tape Extruded white ECTFE Extruded clear ECTFE Extruded white PFA Extruded clear PFA No jacket
Similar mil-spec constructions available (call factory for details) MIL-C7078, MIL-27072, MIL-47206, MIL-13929, MPD-1507
16
MIL-DTL-27500 Type RC-06
Applications Used for aerospace flight vehicles. Primary conductors manufactured in accordance to M22759/11. Identification In accordance with MIL-C-27500 Similar mil-spec constructions available (call factory for details) - MIL-C-7078, MIL-C-27072, MIL-W47206, MIS-C-13929, MPD-1507 Part Number
Primary (AWG)
Stranding (No./AWG)
Primary OD (inches)
Shield OD (inches)
Cable OD (inches)
MS27500-26RC-1S06
26
19/38
.038
.055
.079
6
MS27500-26RC-2S06
26
19/38
.038
.092
.116
10
MS27500-26RC-3S06
26
19/38
.038
.098
.122
13
MS27500-26RC-4S06
26
19/38
.038
.108
.132
16
MS27500-24RC-1S06
24
19/36
.043
.059
.083
7
MS27500-24RC-2S06
24
19/36
.043
.102
.126
13
MS27500-24RC-3S06
24
19/36
.043
.109
.133
16
MS27500-24RC-4S06
24
19/36
.043
.120
.144
19
MS27500-22RC-1S06
22
19/34
.049
.065
.089
10
MS27500-22RC-2S06
22
19/34
.049
.114
.138
15
MS27500-22RC-3S06
22
19/34
.049
.122
.146
20
MS27500-22RC-4S06
22
19/34
.049
.135
.159
25
MS27500-20RC-1S06
20
19/32
.058
.074
.098
11
MS27500-20RC-2S06
20
19/32
.058
.132
.156
20
MS27500-20RC-3S06
20
19/32
.058
.141
.165
27
MS27500-20RC-4S06
20
19/32
.058
.156
.180
35
MS27500-18RC-1S06
18
19/30
.068
.084
.108
15
MS27500-18RC-2S06
18
19/30
.068
.152
.176
28
MS27500-18RC-3S06
18
19/30
.068
.163
.187
38
MS27500-18RC-4S06
18
19/30
.068
.181
.205
47
MS27500-16RC-1S06
16
19/29
.075
.091
.115
17
MS27500-16RC-2S06
16
19/29
.075
.166
.190
33
MS27500-16RC-3S06
16
19/29
.075
.178
.202
46
MS27500-16RC-4S06
16
19/29
.075
.198
.222
59
MS27500-14RC-1S06
14
19/27
.090
.106
.130
23
MS27500-14RC-2S06
14
19/27
.090
.196
.220
45
MS27500-14RC-3S06
14
19/27
.090
.210
.234
62
MS27500-14RC-4S06
14
19/27
.090
.234
.258
79
MS27500-12RC-1S06
12
19/25
.111
.127
.151
33
MS27500-12RC-2S06
12
19/25
.111
.238
.262
68
MS27500-12RC-3S06
12
19/25
.111
.256
.280
95
MS27500-12RC-4S06
12
19/25
.111
.289
.313
126
Cable configurations of up to 10 primaries are also available.
17
All figures referenced are nominal.
Weight (lbs.)
Type STJ Commercial equivalents to Type RC-06
Applications Electrical and electronic installations with ambient temperatures up to 200º C. and voltage requirements to 600 volts. Part Number
Primary (AWG)
Stranding (No./AWG)
Primary OD (inches)
Shield OD (inches)
Cable OD (inches)
Weight (lbs.)
1XE26-734STJ
26
7/34
.038
.055
.073
6
2XE26-734STJ
26
7/34
.038
.092
.110
10
3XE26-734STJ
26
7/34
.038
.098
.116
13
4XE26-734STJ
26
7/34
.038
.108
.126
16
1XE24-1936STJ
24
19/36
.043
.059
.077
7
2XE24-1936STJ
24
19/36
.043
.102
.120
13
3XE24-1936STJ
24
19/36
.043
.109
.127
16
4XE24-1936STJ
24
19/36
.043
.120
.138
19
1XE24-1934STJ
22
19/34
.049
.065
.083
10
2XE24-1934STJ
22
19/34
.049
.114
.132
15
3XE24-1934STJ
22
19/34
.049
.122
.140
20
4XE24-1934STJ
22
19/34
.049
.135
.153
25
1XE20-1936STJ
20
19/32
.058
.074
.092
11
2XE20-1936STJ
20
19/32
.058
.132
.150
20
3XE20-1936STJ
20
19/32
.058
.141
.159
27
4XE20-1936STJ
20
19/32
.058
.156
.174
35
1XE18-1936STJ
18
19/30
.068
.084
.102
15
2XE18-1936STJ
18
19/30
.068
.152
.176
28
3XE18-1936STJ
18
19/30
.068
.163
.187
38
4XE18-1936STJ
18
19/30
.068
.181
.205
47
1XE16-1936STJ
16
19/29
.075
.091
.109
17
2XE16-1936STJ
16
19/29
.075
.166
.190
33
3XE16-1936STJ
16
19/29
.075
.178
.202
46
4XE16-1936STJ
16
19/29
.075
.198
.222
59
1XE14-1936STJ
14
19/27
.090
.106
.124
23
2XE14-1936STJ
14
19/27
.090
.196
.220
45
3XE14-1936STJ
14
19/27
.090
.210
.234
65
4XE14-1936STJ
14
19/27
.090
.234
.258
82
1XE12-1936STJ
12
19/25
.111
.127
.145
33
2XE12-1936STJ
12
19/25
.111
.238
.262
68
3XE12-1936STJ
12
19/25
.111
.256
.280
95
4XE12-1936STJ
12
19/25
.111
.289
.313
126
Cable configurations of up to 10 primaries are also available. All figures referenced are nominal.
18
MIL-DTL-27500 Type RC-09
Applications Used for aerospace flight vehicles. Primary conductors manufactured in accordance to M22759/11. Identification In accordance with MIL-C-27500 Similar mil-spec constructions available (call factory for details) - MIL-C-7078, MIL-C-27072, MIL-W47206, MIS-C-13929, MPD-1507 Part Number
Primary (AWG)
Stranding (No./AWG)
Primary OD (inches)
Shield OD (inches)
Cable OD (inches)
Weight (lbs.)
MS27500-26RC-1S09
26
19/38
.038
.055
.073
6
MS27500-26RC-2S09
26
19/38
.038
.092
.110
10
MS27500-26RC-3S09
26
19/38
.038
.098
.116
13
MS27500-26RC-4S09
26
19/38
.038
.108
.126
16
MS27500-24RC-1S09
24
19/36
.043
.059
.077
7
MS27500-24RC-2S09
24
19/36
.043
.102
.120
13
MS27500-24RC-3S09
24
19/36
.043
.109
.127
16
MS27500-24RC-4S09
24
19/36
.043
.120
.138
19
MS27500-22RC-1S09
22
19/34
.049
.065
.083
9
MS27500-22RC-2S09
22
19/34
.049
.114
.132
14
MS27500-22RC-3S09
22
19/34
.049
.122
.140
19
MS27500-22RC-4S09
22
19/34
.049
.135
.153
24
MS27500-20RC-1S09
20
19/32
.058
.074
.092
11
MS27500-20RC-2S09
20
19/32
.058
.132
.150
19
MS27500-20RC-3S09
20
19/32
.058
.141
.159
26
MS27500-20RC-4S09
20
19/32
.058
.156
.180
35
MS27500-18RC-1S09
18
19/30
.068
.084
.102
14
MS27500-18RC-2S09
18
19/30
.068
.152
.176
27
MS27500-18RC-3S09
18
19/30
.068
.163
.187
37
MS27500-18RC-4S09
18
19/30
.068
.181
.205
47
MS27500-16RC-1S09
16
19/29
.075
.091
.109
16
MS27500-16RC-2S09
16
19/29
.075
.166
.190
32
MS27500-16RC-3S09
16
19/29
.075
.178
.202
45
MS27500-16RC-4S09
16
19/29
.075
.198
.222
59
MS27500-14RC-1S09
14
19/27
.090
.106
.124
23
MS27500-14RC-2S09
14
19/27
.090
.196
.220
45
MS27500-14RC-3S09
14
19/27
.090
.210
.234
62
MS27500-14RC-4S09
14
19/27
.090
.234
.258
79
MS27500-12RC-1S09
12
19/25
.111
.127
.145
32
MS27500-12RC-2S09
12
19/25
.111
.238
.262
65
MS27500-12RC-3S09
12
19/25
.111
.256
.280
91
MS27500-12RC-4S09
12
19/25
.111
.289
.313
123
Cable configurations of up to 10 primaries are also available.
19
All figures referenced are nominal.
Type SE Commercial equivalents to Type RC-09 Applications Electrical and electronic installations with ambient temperatures up to 200º C. and voltage requirements to 600 volts.
Part Number
Primary (AWG)
Stranding (No./AWG)
Primary OD (inches)
Shield OD (inches)
Cable OD (inches)
Weight (lbs.)
1XE24-1936SE
24
19/36
.043
.059
.079
7
2XE24-1936SE
24
19/36
.043
.102
.122
13
3XE24-1936SE
24
19/36
.043
.109
.129
16
4XE24-1936SE
24
19/36
.043
.120
.140
19
1XE22-1934SE
22
19/34
.049
.065
.085
10
2XE22-1934SE
22
19/34
.049
.114
.134
15
3XE22-1934SE
22
19/34
.049
.122
.142
20
4XE22-1934SE
22
19/34
.049
.135
.155
25
1XE20-1932SE
20
19/32
.058
.074
.094
11
2XE20-1932SE
20
19/32
.058
.132
.152
20
3XE20-1932SE
20
19/32
.058
.141
.161
27
4XE20-1932SE
20
19/32
.058
.156
.180
35
1XE18-1930SE
18
19/30
.068
.084
.104
15
2XE18-1930SE
18
19/30
.068
.152
.176
28
3XE18-1930SE
18
19/30
.068
.163
.187
38
4XE18-1930SE
18
19/30
.068
.181
.205
47
1XE16-1929SE
16
19/29
.075
.091
.111
17
2XE16-1929SE
16
19/29
.075
.166
.190
33
3XE16-1929SE
16
19/29
.075
.178
.202
46
4XE16-1929SE
16
19/29
.075
.198
.222
59
1XE14-1927SE
14
19/27
.090
.109
.129
23
2XE14-1927SE
14
19/27
.090
.196
.220
45
3XE14-1927SE
14
19/27
.090
.210
.234
65
4XE14-1927SE
14
19/27
.090
.234
.258
82
1XE12-1925SE
12
19/25
.111
.127
.147
33
2XE12-1925SE
12
19/25
.111
.238
.262
68
3XE12-1925SE
12
19/25
.111
.256
.280
95
4XE12-1925SE
12
19/25
.111
.289
.309
126
Cable configurations of up to 10 primaries are also available. All figures referenced are nominal.
20
MIL-DTL-27500 Type TE-14
Applications Used for aerospace flight vehicles. Primary conductors manufactured in accordance to M22759/16. Identification In accordance with MIL-C-27500 Part Number
Primary (AWG)
Stranding (No./AWG)
Primary OD (inches)
Shield OD (inches)
Cable OD (inches)
MS27500-24TE-1T14
24
19/36
.045
.054
.072
7
MS27500-24TE-2T14
24
19/36
.045
.095
.113
11
MS27500-24TE-3T14
24
19/36
.045
.101
.119
15
MS27500-24TE-4T14
24
19/36
.045
.110
.128
19
MS27500-22TE-1T14
22
19/34
.052
.061
.079
8
MS27500-22TE-2T14
22
19/34
.052
.109
.127
15
MS27500-22TE-3T14
22
19/34
.052
.116
.134
19
MS27500-22TE-4T14
22
19/34
.052
.127
.145
25
MS27500-20TE-1T14
20
19/32
.060
.069
.087
10
MS27500-20TE-2T14
20
19/32
.060
.125
.143
19
MS27500-20TE-3T14
20
19/32
.060
.133
.151
25
MS27500-20TE-4T14
20
19/32
.060
.146
.164
32
MS27500-18TE-1T14
18
19/30
.071
.084
.102
14
MS27500-18TE-2T14
18
19/30
.071
.145
.163
26
MS27500-18TE-3T14
18
19/30
.071
.154
.178
36
MS27500-18TE-4T14
18
19/30
.071
.170
.194
45
MS27500-16TE-1T14
16
19/29
.079
.102
.120
16
MS27500-16TE-2T14
16
19/29
.079
.157
.181
31
MS27500-16TE-3T14
16
19/29
.079
.167
.191
43
MS27500-16TE-4T14
16
19/29
.079
.184
.208
54
MS27500-14TE-1T14
14
19/27
.093
.104
.122
22
MS27500-14TE-2T14
14
19/27
.093
.185
.209
43
MS27500-14TE-3T14
14
19/27
.093
.198
.222
60
MS27500-14TE-4T14
14
19/27
.093
.218
.242
76
MS27500-12TE-1T14
12
19/28
.114
.126
.144
30
MS27500-12TE-2T14
12
19/28
.114
.229
.253
60
MS27500-12TE-3T14
12
19/28
.114
.245
.269
86
MS27500-12TE-4T14
12
19/28
.114
.271
.295
114
All figures referenced are nominal.
21
Weight (lbs.)
MIL-DTL-27500 Type TG-14 Applications Used for aerospace flight vehicles. Primary conductors manufactured in accordance to M22759/18. Identification In accordance with MIL-C-27500 Part Number
Primary (AWG)
Stranding (No./AWG)
Primary OD (inches)
Shield OD (inches)
Cable OD (inches)
Weight (lbs.)
MS27500-24TG-1T14
24
19/36
.036
.054
.072
6
MS27500-24TG-2T14
24
19/36
.036
.095
.113
9
MS27500-24TG-3T14
24
19/36
.036
.101
.119
12
MS27500-24TG-4T14
24
19/36
.036
.110
.128
15
MS27500-22TG-1T14
22
19/34
.043
.061
.079
7
MS27500-22TG-2T14
22
19/34
.043
.109
.127
12
MS27500-22TG-3T14
22
19/34
.043
.116
.134
17
MS27500-22TG-4T14
22
19/34
.043
.127
.145
20
MS27500-20TG-1T14
20
19/32
.051
.069
.087
9
MS27500-20TG-2T14
20
19/32
.051
.125
.163
18
MS27500-20TG-3T14
20
19/32
.051
.133
.178
22
MS27500-20TG-4T14
20
19/32
.051
.146
.194
27
MS27500-18TG-1T14
18
19/30
.061
.084
.102
12
MS27500-18TG-2T14
18
19/30
.061
.145
.163
23
MS27500-18TG-3T14
18
19/30
.061
.154
.178
31
MS27500-18TG-4T14
18
19/30
.061
.170
.194
40
MS27500-16TG-1T14
16
19/29
.070
.090
.108
15
MS27500-16TG-2T14
16
19/29
.070
.157
.181
28
MS27500-16TG-3T14
16
19/29
.070
.167
.191
39
MS27500-16TG-4T14
16
19/29
.070
.184
.208
72
MS27500-14TG-1T14
14
19/27
.085
.104
.122
21
MS27500-14TG-2T14
14
19/27
.085
.185
.209
40
MS27500-14TG-3T14
14
19/27
.085
.198
.222
56
MS27500-14TG-4T14
14
19/27
.085
.218
.242
72
MS27500-12TG-1T14
12
19/25
.107
.126
.144
30
MS27500-12TG-2T14
12
19/25
.107
.229
.253
59
MS27500-12TG-3T14
12
19/25
.107
.245
.269
83
MS27500-12TG-4T14
12
19/25
.107
.271
.295
111
All figures referenced are nominal.
22
Mil-C-17 Coaxial Cable QPL Approved Single braid
Double braid
Triax
Twinax
Harbour supplies a complete line of high temperature, high performance QPL approved MIL-C-17 coax cables for the military, commercial and industrial applications. The specific M17 constructions referenced are manufactured in accordance with the most recent revision of the MIL-C-17 specification. The MIL-C-17 specification defines complete physical and electrical characteristics for each M17 part number, including dimensional parameters, dielectric materials, shield construction, maximum attenuation, and VSWR levels. VSWR Sweep Testing When selecting a 50 ohm coaxial cable, constructions with VSWR requirements are recommended. Manufacturing and sweep testing cables with concern for VSWR ensures a quality cable free of spikes over the referenced frequency range. (Note the test frequencies specified in the electrical characteristics section.) Precision PTFE Dielectrics All of the high temperature, high performance coax cables listed have PTFE dielectrics with high dielectric strength and low capacitance in proportion to the dielectric constant. All PTFE dielectrics are manufactured with tolerances tighter than the MIL-C-17 specification to ensure uniformity of electrical characteristics, especially impedance, attenuation and VSWR. Tape wrapped PTFE Constructions Harbour also manufactures PTFE tape wrapped cables to a previous revision of the MIL-C-17 specification. These constructions can withstand operating temperatures up to 250° C. versus 200° C. for FEP jacketed cables. Also, PTFE tape wrapped cables are generally more flexible than their FEP jacketed counterparts. UL Approvals All of Harbour’s M17 part numbers manufactured to the MIL-C-17 specification may be ordered with UL and FT4 approvals.
23
Mil-C-17 Coaxial Cables Physical Characteristics: M17 Number
Center Conductor
PTFE Overall Minimum Operating Weight Dielectric Shield Jacket Diameter Recommended Temp. (°C) (lbs./MFT) Diameter Bend Radius
M17/60-RG142 .037” SCCS M17/93-RG178 .0120”(7/.004”)SCCS M17/93-00001 .0120”(7/.004”)SCCS
.116” .033” .033”
SPC(2) SPC SPC
M17/94-RG179 .0120”(7/.004”)SCCS M17/95-RG180 .0120”(7/.004”)SCCS M17/110-RG302 .0253”SCCS M17/111-RG303 .037”SCCS M17/113-RG316 .0201”(7/.0067”)SCCS M17/127-RG393 .094”(7/.0312”)SC M17/128-RG400 .0384”(19/.008”)SC M17/131-RG403 .0120”(7/.004”)SCCS M17/152-00001 .0201”(7/.0067”)SCCS
.063” .102” .146” .116” .060” .285” .116” .033” .060”
M17/158-00001 M17/169-00001 M17/170-00001 M17/172-00001 M17/174-00001 M17/175-00001 M17/176-00002
.037”SCCS .0120”(7/.004”)SCCS .037”(SCCS .0201”(7/.0067”)SCCS .094”(7/.0312”)SCCS .0384”(19/.008”)SC .0235”(19/.005”)SPA(2)
PTFE Tape Wrap Jacketed RG Cables RG 187 A/U .0120”(7/.004)SCCS RG 188 A/U .0201”(7/.0067)SCCS RG 195 A/U .0120”(7/.004)SCCS RG 196 A/U .0120”(7/.004)SCCS
FEP FEP PFA
.195” .071” .071”
1.0” 0.4” 0.4”
-55 +200 -55 +200 -55 +230
43.0 6.3 6.3
SPC FEP SPC FEP SPC FEP SPC FEP SPC FEP SPC(2) FEP SPC(2) FEP SPC(2) FEP(2) SPC(2) FEP
.100” .141” .202” .170” .098” .390” .195” .116” .114”
0.4” 0.7” 1.0” 0.9” 0.5” 2.0” 1.0” 0.6” 0.6”
-55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200
10.8 19.8 40.0 31.0 11.5 165.0 50.0 15.0 18.5
.116” .033” .116” .060” .285” .116” .042”
SPC(2) SPC SPC SPC SPC(2) SPC(2) SPA
FEP FEP FEP FEP FEP FEP PFA
.195” .071” .170” .098” .390” .195” .129”
1.0” 0.4” 0.9” 0.5” 2.0” 1.0” 0.6”
-55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +230
43.0 6.3 31.0 11.5 165.0 50.0 18.0
.063 .060 .102 .034
SPC SPC SPC SPC
PTFE PTFE PTFE PTFE
.100” .100” .141” .067”
0.5” 0.5” 0.7” 0.4”
-55 +250 -55 +250 -55 +250 -55 +250
10.0 11.0 18.0 6.0
Comments
M17/93-RG178 w/extended temp. range
Triaxial M17/93-RG178 Double shielded M17/113-RG316 Unswept M17/60-RG142 Unswept M17/93-RG178 Unswept M17/111-RG303 Unswept M17/113-RG316 Unswept M17/127-RG393 Unswept M17/128-RG400 Controlled impedance twinax Flexible, 250° C. rated Flexible, 250° C. rated Flexible, 250° C. rated Flexible, 250° C. rated
Electrical Characteristics: M17 Number
Impedence Capacitance Max. Operating (ohms) (pF/ft) Voltage (RMS)
M17/60-RG142 50 +/- 2 29.4 M17/93-RG178 50 +/- 2 29.4 M17/93-00001 50 +/- 2 29.4 M17/94-RG179 75 +/- 3 19.4 M17/95-RG180 95 +/- 5 16.4 M17/110-RG302 75 +/- 3 19.4 M17/111-RG303 50 +/- 2 29.4 M17/113-RG316 50 +/- 2 29.4 M17/127-RG393 50 +/- 2 29.4 M17/128-RG400 50 +/- 2 29.4 M17/131-RG403 50 +/- 2 29.4 M17/152-00001 50 +/- 2 29.4 M17/158-00001 50 +/- 2 29.4 M17/169-00001 50 +/- 2 29.4 M17/170-00001 50 +/- 2 29.4 M17/172-00001 50 +/- 2 29.4 M17/174-00001 50 +/- 2 29.4 M17/175-00001 50 +/- 2 29.4 M17/176-00002 77 +/- 7 19.0 PTFE Tape Wrap Jacketed RG Cables RG 187 A/U 75 +/- 3 19.4 RG 188 A/U 50 +/- 2 29.4 RG 195 A/U 95 +/- 5 15.4 RG 196 A/U 50 +/- 2 29.4
100 MHz
Maximum attenuation (dB/100ft) @ 400 MHz 1 GHz 3 GHz 5 GHz 10 GHz
1900 1000 1000 1200 1500 2300 1900 1200 2500 1900 1000 1200 1900 1000 1900 1200 2500 1900 1000
5.5 16.0 16.0 3.9 11.0 2.4 4.5 11.5 -
11.7 33.0 33.0 21.0 17.0 8.0 8.6 21.0 5.0 10.5 37.0 24.0 11.7 33.0 8.6 21.0 5.0 10.5 -
19.0 52.0 52.0 15.0 38.0 8.8 17.0 40.0 1.4
1200 1200 1500 1000
11.0 -
21.0 21.0 17.0 29.0
38.0 -
35.0 94.0 94.0 26.0 28.0 58.0 18.0 38.0 75.0 -
58.0
Max. Test/Cut off (Freq-GHz)
48.0 24.6 50.0 110.0 -
37.0 78.0 170.0 -
8.0/32.6 3.0 /110.8 3.0 /110.8 0.4/66.5 0.4/43.8 3.0/29.1 3.0/32.6 3.0/62.3 11.0/13.2 12.4/32.3 0.4/110.8 12.4/62.3 0.40/32.6 0.40/110.8 0.40/32.6 0.40/62.3 0.40/13.2 0.40/32.3 -
-
-
0.40/66.5 3.0/62.3 0.40/43.8 0.40/110.8
“Maximum test frequencies” are those as referenced on individual slant sheets of the MIL-C-17 specification.
24
Buying Directory MIL-C-17 COAXIAL CABLE Swept
Unswept
M16/60-RG142 M17/93-RG178 M17/93-00001 M17/94-RG179 M17/95-RG180 M17/110-RG302 M17/111-RG303 M17/113-RG316 M17/128-RG400 M17/131-RG403 M17/152-00001 M17/176-00002
M17/158-00001 M17/169-00001 M17/170-00001 M17/172-00001 M17/174-00001 M17/175-00001 Commercial Grade
RG 187 A/U RG 188 A/U RG 195 A/U RG 196 A/U RG 393 IMAX
SPECIALTY COAX Communications Network Coaxial*
CN142 CN316
CN178 CN400
CN179
*Available in single or double braid configurations with Tin Plated Copper or Silver Plated Copper Braid.
Low Loss, High Frequency Coax
LL120 LL142 LL304 LL393-1 LL393-2
SB142 SB304 SB393 SB405
SS402 SS405
Low Noise Coax
High Strength Coax
LN178 LN179 LN180
HS178 HS179 HS180
SPECIALTY INDUSTRIAL WIRES
SureformPlus Hand Formable Coax Unjacketed Jacketed
SC401 SC402 SC405
SC401FJ SC402FJ SC405FJ
SC401PJ SC402PJ SC405PJ
High Performance Foam - NEC 800, NEC 820, CMR, Halogenated, Non-Halogen, CATVR
HPF195 HPF240
HPF200 HPF400
PREMISE NETWORKING CABLES Plenum, Coaxial FEP Core
NEC 800, CMP RG-59 RG-58-Thinnet RG-6 100 Ohm Twinax
RG-62
Local Area Network Cable - PVC & Plenum Rated
Category 3 XH
Category 5e
Category 5e
Category 6
Power-limited cables - NEC725, NEC800
CL2P, CMP, MMP, FPLP, CSA, FT4, FT6 Low-Cap Mid-Cap Loop Sound and Control Signaling Ethernet Transceiver IEEE 802.3 Point-of-sale cables
US 800 659 4733 800 65 WIRED Canada 450 293 5304 www.harbourind.com
[email protected] 25
INDUSTRIAL WIRE & CABLE TCGT 250°C UL AND CSA UL Style AWG Sizes Voltage 5315 #24-#2 300 5288 #24-#8 600 TGGT 250°C UL AND CSA UL Style AWG Sizes Voltage 5257 #24-#8 300 5156 #24-#2 600 MG 450°C UL and CSA UL Style AWG Sizes Voltage 5128 #22-#4 300 5107 #22-#4/0 600 SLIPSTRIP 450°C UL and CSA UL Style AWG Sizes Voltage 5360 #30-#4/0 300 5359 #30-#4/0 600 UL/CSA FEP Wires (AWM) UL/CSA AWG Voltage Temp. °C. 3135/I A/B #8-#2 600 200 3127/I A/B #8-#2 600 150 3139/I A #24-#12 600 200 3241/I A/B #24-#14 300 200 3304/n/a #22-#12 10KV 200 3239/TV-15 #24-#10 15KV 150 3239/TV-20 #24-#10 20KV 150 3239/TV-25 #24-#10 25KV 150 3239/TV-30 #24-#10 30KV 150 3239/TV-40 #24-#10 40KV 150 3239/TV-50 #24-#10 50KV 150
Flameguard - 2 hour Fire Rated Heatguard - Temperatures to 1000 º C. Hartrex - Resistant to 1000 Megrads SLAR - Nuclear robotics cable
UL and CSA LEAD WIRES PTFE STYLES UL/CSA AWG Sizes Voltage Temp. °C. 1164/1 A/B #28-#12 300 200 1180/1 A/B #28-#12 300 200 1198/1 A/B #24-#12 300 150 1199/1 A/B #24-#12 600 200 1212/1 A/B #32-#12 n/r 200 1213/1 A/B #32-#12 n/r 200 1371/1 A/B #32-#12 n/r 200 1512/1 A/B #16-#14 n/r 200 1538/1 A/B #32-#12 125 105 1584/1 A/B #30-#12 1000 200 1659/1 A/B #26-#12 600 250 1716/1 A/B #32-#12 150 1500 1815/1 A/B #32-#12 300 250 UL FEP Wires (AWM) UL/CSA AWG Sizes Voltage Temp. °C. 1226/I A/B #26-#20 n/r 80 1227/I A/B #26-#14 n/r 105 1330/I A/B #26-#4/0 600 200 1331/I A/B #26-#4/0 600 150 1332/I A/B #36-#10 300 200 1333/I A/B #26-#4/0 300 150 1371/I A/B #26-#6 n/r 105 1538/I A/B #30-#6 125 105 1716/I A/B #30-#6 150 150 ETFE Wires UL/CSA AWG Sizes Voltage Temp. °C. 1517/I A/B #24-#20 n/r 105 1586/I A/B #24-#6 n/r 105 1609/I A/B #24-#6 125 105 1610/I A/B #24-#10 n/r 105 1671/I A #30-#10 300 150 10086/I A/B #24-#10 600 200 10109/I A/B #24-#10 300 200 10125/I A/B #30-#4/0 300 150 10126/I A/B #30-#4/0 600 150
Custom designs utilizing the following components are available upon request: SOLID & STRANDED CONDUCTORS Bare Copper • Grade A Nickel • Nickel Plated Copper • Nickel Plated High Strength Copper Alloy • Nickel Plated Steel • Nickel Plated Copper Clad Steel • Silver Plated High Strength Copper Alloy • Silver Plated Copper Clad Steel • Silver Plated Copper • Tin Plated Copper • Thermocouple Alloys • Resistive Alloys • Oxygen Free Nickel Plated Copper • Oxygen Free Silver Plated Copper • Tin Overcoat Copper
SHIELD MATERIALS Nickel Plated Copper • Nickel Plated Copper Clad Steel • Silver Plated Copper • Silver Plated Copper Clad Steel • Stainless steel • Flat Braid • Round Braid • Spirally Applied Flat • Aluminum Polyester Tape • Aluminum Polyimide Tape
INSULATION & JACKETING MATERIALS Extruded Materials ETFEP • ECTFE • FRPVC • FEP • PVC • PEEK • PTFE • PVDF • PFA • TPE Polyethylene • Polyimide • Polyurethane • Silicone Rubbers Tapes Ceramic • Fiberglass • Mica • Polyester • PTFE Yarns Aramid • Ceramic • Fiberglass • K-fiber • Polyimide • Polyester • Fiberglass
The UL and CSA styles listed here represent the most commonly requested items. Harbour is approved for many more styles not listed here. If you do not see a particular style that you need call 1 800 659 4733 to check availability.
Hook-Up Wire MIL-W-16878* Revision F. PTFE Insulation
MIL-W-22759 Revision E PTFE Insulation
Extruded Insulation
Part No. NEMA HP-3 AWG Size Conductor Voltage Temp. °C. M16878/4 E #30-#10 SPC 600 200 M16878/5 EE #30-#8 SPC 1000 200 M16878/6 ET #30-#20 SPC 250 200 M16878/23 ET #30-#20 NPC 250 260 M16878/25 E #22-#12 NPC 600 260 M16878/27 EE #25-#12 NPC 1000 260 Wrapped Insulation
M16878/21 M16878/22 M16878/26 M16878/28 M16878/34 M16878/35
E EE E EE EE EE
#22-#10 #22-#6 #22-#10 #22-#6 #22-#8 #22-#8
SPC SPC NPC NPC SPC NPC
600 1000 600 1000 1000 1000
200 200 260 260 200 260
K KK KT
#26-#8 #26-#4/0 #26-#20
SPC SPC SPC
600 1000 250
200 200 200
#24-#10 #24-#4/0 #24-#10 #24-#4/0
SPC SPC TPC TPC
600 1000 600 1000
200 200 150 150
TPC SPC
1000 1000
150 200
Silicone Rubber Insulation
M16878/7 M16878/8 M16878/29 M16878/30
-
Silicone Rubber and Fiberglass Insulation
M16978/31 M16878/32
AWG Size #28-#8 #28-#12 #28-#8 #28-#12 #28-#20 #28-#20 #28-#20 #28-#20
Conductor SPC NPC SPC NPC SPTF NPTF SPTF NPTF
Voltage 1000 1000 600 600 1000 1000 600 600
Temp.°C. 200 260 200 260 200 260 200 260
Mineral Filled PTFE Insulation
M22759/5 M22759/6 M22759/7 M22759/8
#24-#10 #24-#10 #24-#10 #24-#10
SPC NPC SPC NPC
600 600 600 600
200 260 200 260
#24-#2/0 #26-#20 #26-#10 #26-#20
TPC SPA TPC SPA
600 600 600 600
150 150 150 150
ETFE Insulation
FEP Insulation
M16878/11 M16878/12 M16878/13
Part No. M22759/9 M22759/10 M22759/11 M22759/12 M22759/20 M22759/21 M22759/22 M22759/23
-
#24-#4/0 #24-#4/0
*MIL-W-16878 is obsolete and no longer active. Specification requirements for equivalent constructions are found in NEMA HP-3
In addition to the referenced Military Specifications, Harbour Industries also manufactures hook-up wire and cables to the following specifications:
Hook-Up Wires (MIL-W-) 8777, 81381, 81822, 47206
Cables (MIL-C-) 7078, 27072, 55021/2B
Other MPD-1506, MPD-1507, MIS-13928, MIS-13929
M22759/16 M22759/17 M22759/18 M22759/19
MILITARY/COMMERCIAL CABLES Shielded or unshielded, extruded FEP, ETFE or tape wrapped PTFE jackets using the following components: MIL-C-27500 PTFE Insulated Primaries Symbol Primaries LE M22759/9 LH M22759/10 RC M22759/11 RE M22759/12 TK M22759/20 TM M22759/22 TN M22759/23
AWG Size #28-#8 #28-#12 #28-#8 #28-#12 #28-#20 #28-#20 #28-#20
ETFE Insulated Primaries TE M22759/16 TF M22759/17 TG M22759/18 TH M22759/19
#26-#2/0 #26-#20 #26-#10 #26-#20
Commercial Cables SE FEP Extruded Jacket STJ PTFE Wrapped Jacket
Harbour Industries, Inc. makes every effort to ensure the accuracy of the information contained in this publication. However, Harbour is not responsible for errors or changes.
US 800 659 4733 800 65 WIRED Canada 450 293 5304 www.harbourind.com e-mail -
[email protected] Harbour I N D U S T R I E S
High Performance Wire & Cable
26