Homeline® Circuit Breakers - Mayer Electric Supply

Report 5 Downloads 46 Views
www.us.schneider-electric.com

Homeline® Circuit Breakers

Plug-On Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501

FOR CURRENT INFORMATION

Table 1.34:

HOM 2P 2 Spaces Required

HOM2200BB Branch Circuit Breaker 4 Spaces Required

HOM

Ampere Rating

AIR

15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 110 A 125 A 150 A 175 A 200 A

10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA

1P—120/240 Vac Cat. No. HOM115 ab HOM120 ab HOM125 b HOM130 b — HOM140 b — HOM150 b — — — — — — — — — —

New!

HOM 1P AFI (Arc Fault Circuit Interrupter) 1 Space Required

1P—120/240 Vac

Amperes

Cat. No. HOM115HMb HOM120HMb

Circuit Breaker Type Arc-fault Circuit Interrupter Combination Arc-fault Circuit interrupter

Table 1.40:

AIR

10 kA 10 kA 10 kA 10 kA 10 kA

Table 1.38:

1 Space Required Cat. No. HOM115GFI HOM120GFI — — —

2 Spaces Required

$ Price 141.00 141.00 — — —

Cat. No. HOM215GFI HOM220GFI HOM230GFI HOM240GFI HOM250GFI

$ Price 275.00 275.00 275.00 275.00 275.00

HOM-EPD—10 k AIR

Homeline Equipment Protection Device—Circuit Breakers with 30 mA Equipment Ground Fault Protection (UL Listed)

15 A 20 A 25 A 30 A 40 A 50 A

2P—120/240 Vac Common Trip

1P—120 Vac Cat. No. HOM115EPD HOM120EPD — — — —

$ Price 249.00 249.00 — — — —

DE3D

Cat. No. HOM215EPD HOM220EPD HOM225EPD HOM230EPD HOM240EPD HOM250EPD

DE3C

DE2E

$ Price 440.00 440.00 440.00 440.00 440.00 440.00

Discount Schedule

2P Tandem—120/240 Vac (Two Spaces Required)

Circuit Breaker Wire Sizese Wire Size (AWG/kcmil)

Breaker Type

Ampere Rating

Aluminum

HOM 1P

15–30 A

14–8 AWG

HOM 2P HOMT and Quad Quad Only HOM-GFI - 1P HOM-GFI - 2P

Table 1.42:

2P—120/240 Vac Common Trip

AIR

1P 2P Cat. No. $ Price (2) 15 A 15 A 10 kA HOMT1515215 b 80.00 (2) 15 A 20 A 10 kA HOMT1515220 b 80.00 (2) 15 A 25 A 10 kA HOMT1515225 b 80.00 (2) 15 A 30 A 10 kA HOMT1515230 b 80.00 (2) 15 A 40 A 10 kA HOMT1515240 b 80.00 (2) 15 A 50 A 10 kA HOMT1515250 b 80.00 (2) 20 A 20 A 10 kA HOMT2020220 b 80.00 (2) 20 A 25 A 10 kA HOMT2020225 b 80.00 (2) 20 A 30 A 10 kA HOMT2020230 b 80.00 (2) 20 A 40 A 10 kA HOMT2020240 b 80.00 (2) 20 A 50 A 10 kA HOMT2020250 b 80.00 Note: Typical catalog number (e.g. HOMT 1515230) represents two 1P, outer poles (two 15 A 1P CBs) and one 2P inner circuit breaker with common trip (one 30 A 2P CB).

$ Price 150.00 150.00 150.00 150.00

1P Tandem—120/240 Vac (One Space Required)

HOMT Quad Tandem Circuit Breakers

Ampere Ratingd

— — —

Poles 120 Cat. No. Vac 1 HOM115AFIb 1 HOM120AFIb 1 HOM115CAFIb 1 HOM120CAFIb

1P—120 Vac

Amperes

© 2007 Schneider Electric All Rights Reserved

Ampere Rating 15 A 20 A 15 A 20 A

AIR

Cat. No. $ Price 15 and 15 A 10 kA HOMT1515 b 34.90 15 and 20 A 10 kA HOMT1520 b 34.90 20 and 20 A 10 kA HOMT2020 b 34.90 30 and 15 A 10 kA HOMT3015 b 34.90 30 and 20 A 10 kA HOMT3020 b 34.90 a UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. b UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers.

Table 1.41:

2Ps $ Price 18.40 18.40

HOM-GFI circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 milliamperes or more. Table 1.37: HOM-GFI

15 A 20 A 30 A 40 A 50 A

HOM 2P GFI (With Ground Fault Circuit Interrupter) 2 Spaces Required

$ Price 40.30 40.30 40.30 40.30 40.30 40.30 40.30 40.30 40.30 82.00 112.00 112.00 112.00 246.00 246.00 285.00 285.00 285.00

Ampere Rating d

Homeline Arc Fault Circuit Interrupters—Provide overload and short circuit protection, plus arc fault protection in accordance with UL 1699. Table 1.36: HOM-AFI

Ampere Rating

HOM 1P GFI (With Ground Fault Circuit Interrupter) 1 Space Required

Cat. No. HOM215b HOM220b HOM225b HOM230b HOM235b HOM240b HOM245b HOM250b HOM260b HOM270b HOM280b HOM290b HOM2100 b HOM2110 b HOM2125 b HOM2150BB bc HOM2175BB bc HOM2200BB bc

High magnetic trip circuit breakers are recommended for applications where high initial inrush current may occur. Table 1.35: HOM-HM

15 A 20 A

HOMT Quad Circuit Breaker 2 Space Required

2P—120/240 Vac Common Trip

$ Price 17.50 17.50 17.50 17.50 — 17.50 — 17.50 — — — — — — — — — —

HOMT Tandem Circuit Breakers

40–50 A

8–2 AWG

15–30 A

14–8 AWG

35–70 A 80–125 A 150–200 A 15–30 A 40–50 A 15–20 A 15–50 A

8–2 AWG 4–2/0 AWG 4 AWG–300 kcmil 14–8 AWG 6–12 AWG 14–10 AWG 12–4 AWG

Copper 14–8 AWG or (2) 14–10 AWG 8–2 AWG 14–8 AWG or (2) 14–10 AWG 8–2 AWG 4–2/0 AWG 4 AWG–300 kcmil 14–8 AWG 6–14 AWG 14–10 AWG 14–6 AWG

Accessories

Description Cat. No. $ Price Handle Attachments Handle Tie: Converts any two adjacent 120/240 Vac HOM1HTg 2.30 single HOM circuit breakers to independent trip 2P Handle Tie: Converts any two adjacent 120/240 Vac 1P side-by-side HOMT circuit breakers to independent HOMTHTg 2.50 trip 2P Handle Clamp: Clamp for holding HOM 1P handle in QO1LOh 2.50 the ON or OFF position Handle Blocking Device: Attaches to standard HOM 2P circuit breakers for holding the handle in the OFF HOM2HBDg 7.10 position Handle Padlock Attachment: For padlocking 1P HOM1PAg 6.60 Standard HOM breakers in the ON or OFF position. 15–70 A HOM2PALAg 6.60 Handle Padlock Attachment: For padlocking 2P Standard HOM circuit 80–125 A HOM2PAHAg 6.60 breakers in ON or OFF position 150–200 A HOM2PAVHAg 33.60 Handle Padlock Attachment: For padlocking center HOMQPA 6.60 poles of Homeline Quad breakers in the OFF position. Handle Padlock Attachment: For 50–125 A QOM1PAfh 7.20 padlocking main circuit breakers in convertible load center 100–225 A QOM2PAfh 7.20 in OFF position Sub-Feed Lugs 125 A 2P plug-on—2 spaces required HOML2125 31.70 225 A 2P plug-on—4 spaces required HOML2225c 197.00 c Requires four spaces (1 AWG–300 kcmil Al/Cu). Use only in 1Ø panel rated 150 A or greater. d 15–20 A tandem or quad tandem circuit breakers are suitable for use with 60oC or 75oC conductors. 25–50 A tandem or quad tandem circuit breakers are suitable for use with 75oC conductors only. e 15–30 A circuit breakers are suitable for use with 60oC or 75oC conductors. 40–125 A circuit breakers are suitable for use with 75oC conductors. f 50–125 A QOM1 frame size; 100–225 A QOM2 frame size. g DE3C Discount Schedule h DE2E Discount Schedule

Moodified 10/4/07

LOAD CENTERS

HOM 1P 1 Space Required

Table 1.39:

1-13

1

The Square D Homeline circuit breakers are in a 1 in. wide format for 1-pole circuit breakers. They are designed to plug into Homeline load centers that are available from 4 to 42 circuits. The Square D exclusive Qwik-Open® mechanism, with a trip reaction within 1/60th of a second, is standard on all 15 A and 20 A circuit breakers.

Selection Information

Miniature Circuit Breakers Class 500, 600

www.us.schneider-electric.com FOR CURRENT INFORMATION

QO® Circuit Breakers











1

1

2

1

2

1

X

X

10–100

X

15–50b

X

15–50

10 — — — — — — — — — — —

15–20

10 10 — — — — — — — — — —

15–50

10 10 — — — — — — — — — —

2

15–20

Current Range

— 1

10 — — — — — — — — — — —

10 10 — — — — — — — — — —

10 — — — — — — — — — — —

10 10 — — — — — — — — — —

10 10 — — — — — — — — — —

10 10 10 10 — — — — — — 5f 5 f — — — — — — — — — — — —

X

X

X

X

3











2

1

2

3

1

10 10 10 — — 5f — — — — — —

10 10 10 — — — — — — — — —





X



QHB



QOBAFI

QOBQOBVHAFI QOB-GFI VHGFI QOB-EPD





















2,3 a 1,2

3

1

1

1

1

2

1

1

2

22 22 — — — — — — — — — —

22 22 — — — — — — — — — —

22 22 22 — — — — — — — — —

22 22 — — — — — — — — — —

22 22 22e — — — — — — — — —

65 65 — — — — — — — — — —









15–60



2

QOB-VH

15–30



1



15–30





15–60

Unit Mount Number of Poles

QOB-H —

QO- QO-EPD QO-GFI VHGFI

15–30



QOVHAFI

15–30



QOAFI

15–20



QOT

15–30



QH

15–30



15–20



15–200m



15–50



QO-VH

15–150

QOB

Bolt-on

QO-H

15–30

QO

15–100

HOMT

15–30

HOMEPD

15–125

HOMGFI

15–100

HOMAFI

10–100

HOM

10–200m

Plug-on Circuit Breaker Type

15–30

HOM Circuit Breakers

65 65 65 — — — — — — — — —

10 10 — — — — — — — — — —

10 — — — — — — — — — — —

22 — — — — — — — — — — —

10 — — — — — — — — — — —

10 10 — — — — — — — — — —

22 — — — — — — — — — — —

10 — — — — — — — — — — —

10 10 — — — — — — — — — —

X



X





X



Interrupting Ratings UL/CSA Rating (kA) (50/60 Hz)c

DC Ratings

120 Vac 120/240 Vac 240 Vac d 277 Vac 480Y/277 Vac 48 Vdc 60 Vdc 65 Vdc 125 Vdc 250 Vdc

IEC 60947-2 (50/60 Hz)g

IEC (Icu)

Special Ratings Fed. Specs W-C-375B/GEN

HACR h NOM

Other Standard

X

— HACRi NOM

HACR h

HACR i

X



X





— HACR i



NOM



NOM

Accessories and Modifications

7 MINIATURE AND MOLDED CASE CIRCUIT BREAKERS

Shunt Trip j Undervoltage Trip Auxiliary Switches j Alarm Switchj Handle Operators Handle Padlock Attachment

— — — — —

— — — — —

— — — — —

— — — — —

— — — — —

— — — — —

— — — — —

— — — — —

X — X X —

X — X X —

X — X X —

X — X X —

X — X X —

X — X X —

X — X X —

X — X X —

Xk — Xk Xk —

X — X X —

X — X X —

X — X X —

— — — — —

— — X X —

— — X X —

— — X X —

— — X X —

— — X X —

— — X X —

X

X

X









Xl

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X —

X —

X —

X —

X —

X —

X —

X —

X X

X X

X X

X —

X —

X —

X —

X —

X —

X —

X —

X —

X —

X —

X —

X —

X —

X —

X —

Trip System Type Thermal-magnetic Molded Case Switch Dimensions (1P Unit Mount) 3.13 (79) 3.5 (89) a 1.00 (25) 0.75 (19) a 2.98 (76) 2.92 (74) a Pages Page 1-13 Pages 7-10, 7-11 a See page 7-53 for dimensions for: QOB2150VH, QOB3110VH, QOB3125VH and QOB3150VH. b HOMT tandem is 30 A maximum. HOMT quad tandem has 20 A maximum on outside poles, and 50 A maximum on the inside poles. c AFI, EPD and GFI products are rated 60 Hz only. d See the Supplemental Digest for 3Ø corner grounded systems. e 22 kA @ 240 Vac for 3P only. f 1P and 2P, 10–70 A and 3P 10–60 A only. g See the Supplemental Digest for circuit breakers with IEC ratings. h HACR on HOM 1P 15–50 A and 2P 15–100 A i HACR on QO, QOB 1P 10–70 A, 2P 15–100 A, 3P 10–100 A; QOB-VH 1P 15–70 A, 2P 15–125 A, 3P 15–100 A j Factory-installed option only k Factory-installed accessories are not available on QOB-VH 2P150 A and 3P 110–150 A l Handle padlock attachment available for HOMT quad tandem only. m 2P 150–200 A requires 4P width. Dimensions (1P Unit Mount) in. (mm)

7-2

Height Width Depth

© 2007 Schneider Electric All Rights Reserved

Selection Information Class 500, 600

www.SquareD.com For the most up-to-date information

QO® Circuit Breakers

HOM Circuit Breakers

HOM

HOMAFI

HOMGFI

HOMEPD

HOMT

QO QOB

... ... ... ... 2

3

1

...

... ...

...

...

...

...

...

...

...

...

1

1

1

1

2

1

1

2

2,3l 1,2

3

10

10

10

10

10

10

10

10

10

10

10

22

22

22

22

22

65

65

10

10

22

10

10

22

10

10

10

...

...

10

...

10

10

10

10

10

10

22

22

22

22

22

65

65

10

...

...

...

10

...

...

10

...

...

...

...

...

...

...

...

... ...

10

10

. . . . . . 22 . . . 22d . . . 65

...

...

...

...

...

...

...

... ...

15–30

10

15–30

15–60

1

15–30

2

15–60

3

15–30

2

10

15–20

Current Range

...

... 1

15–30

1

15–30

...

2

15–30

...

1

15–150

...

2

15–30

...

1

15–100

...

1

15–125

...

2

QOB- QOB- QOB-GFI QOB- QOB-EPD AFI VHAFI VHGFI

15–30

...

1

...

15–100

...

QHB

QOB-VH

10–100

Unit Mount Number of Poles

QOB-H . . . . . . . . .

10–200

...

10–100

...

15–50a

...

15–50

...

15–20

...

15–50

...

QO- QO-GFI QO- QO-EPD VHAFI VHGFI

QOT

15–20

...

QOAFI

QH

15–200

...

QO-VH

15–50

Bolt-on

QO-H

15–20

Plug-on Circuit Breaker Type

CIRCUIT BREAKERS

Interrupting Ratings 120 Vac UL/CSA 120/240 Vac Rating (kA RMS) 240 Vacc (50/60 Hz AC) 277 Vac b 480Y/277 Vac

6

DC Ratings

...

...

...

...

...

...

...

...

... ... ...

...

... ... ... ...

...

... ...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

... ... ...

...

... ... ... ...

...

... ...

...

...

...

...

...

...

...

...

48 Vdc

...

...

...

...

...

...

...

...

5 e 5e 5 e

...

... ... ... ...

...

... ...

...

...

...

...

...

...

...

...

60 Vdc

...

...

...

...

...

...

...

...

... ... ...

...

... ... ... ...

...

... ...

...

...

...

...

...

...

...

...

65 Vdc

...

...

...

...

...

...

...

...

... ... ...

...

... ... ... ...

...

... ...

...

...

...

...

...

...

...

...

125 Vdc

...

...

...

...

...

...

...

...

... ... ...

...

... ... ... ...

...

... ...

...

...

...

...

...

...

...

...

250 Vdc

...

...

...

...

...

...

...

...

... ... ...

...

... ... ... ...

...

... ...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

... ... ...

...

... ... ... ...

...

... ...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

... ... ...

...

... ... ... ...

...

... ...

...

...

...

...

...

...

...

...



















...



...







...



...

...



...

IEC 60947-2 IEC (50/60 Hz AC) (Ultimate f Rating)

Special Ratings Fed. Specs W-C-375B/GEN Other Standard

HACR g NOM

... ... HACRh NOM

HACR g

... ... ... HACRh

...

... ...

. . . HACR h

...

NOM

...

NOM

Accessories and Modifications Shunt Trip

...

...

...

...

...

...

...

...

✓i ✓i ✓i

✓i

✓i ✓i ✓i ✓i ✓ij ✓i ✓i ✓i

...

...

...

...

...

...

...

Undervoltage Trip

...

...

...

...

...

...

...

...

... ... ...

...

... ... ... ...

...

...

...

...

...

...

...

...

Auxiliary Switches

...

...

...

...

...

...

...

...

✓i ✓i ✓i

✓i

✓i ✓i ✓i ✓i ✓ij ✓i ✓i ✓i

...

✓i

✓i ✓i

✓i

✓i ✓i

...

... ...

Alarm Switch

...

...

...

...

...

...

...

...

✓i ✓i ✓i

✓i

✓i ✓i ✓i ✓i ✓ij ✓i ✓i ✓i

...

✓i

✓i ✓i

✓i

✓i ✓i

Handle Operators

...

...

...

...

...

...

...

...

... ... ...

...

... ... ... ...

...

... ...

...

...

...

...

...

...

...

...

Handle Padlock Attachment







...

...

...

...

✓k











































Trip System Type Thermal-magnetic



















































Molded Case Switch

...

...

...

...

...

...

...

...







...

... ... ... ...

...

... ...

...

...

...

...

...

...

...

...

Dimensions (1-pole Unit Mount)

Dimensions (1P Unit Mount)

Height IN (mm)

3.13 (79)

3.5 (89)l

Width IN (mm)

1.00 (25)

0.75 (19)l

Depth IN (mm) Pages

2.98 (76)

2.92 (74)l

Page 6-9

Pages 6-10

a HOMT tandem is 30 A maximum. HOMT quad tandem has 20 A maximum on outside poles, and 50 A maximum on the inside poles. b AFI, EPD and GFI products are rated 60 Hz only. c See Supplemental Digest for 3 phase corner grounded systems. d 22 kA @ 240 Vac for 3-pole only. e 1- and 2-pole, 10–70 A and 3-pole 10–60 A only. f See Supplemental Digest for circuit breakers with IEC ratings. g HACR on HOM 1-pole 15–50 A and 2-pole 15–100 A h HACR on QO, QOB 1-pole 10–70 A, 2-pole 15–100 A, 3-pole 10–100 A; QOB-VH 1-pole 15–70 A, 2-pole 15–125 A, 3-pole 15–100 A i Factory-installed option only j Factory-installed accessories are not available on QOB-VH 2-pole 150 A and 3-pole 110–150 A k Handle padlock attachment available for HOMT quad tandem only. l See page 6-49 for dimensions for: QOB2150VH, QOB3110VH, QOB3125VH and QOB3150VH. 9/8/03

6-2

© 2003 Schneider Electric All Rights Reserved 9/8/03