ON THE WELLHEAD DOWNHOLE WELL ASSEMBLY

Report 4 Downloads 59 Views
ON THE WELLHEAD Simple Installation and Removal . Adds 6.5” to Wellhead height. Can adapt to any A.P.A. Wellhead in its range. 5 No Wellhead Modification Required. 5 No custom built Tubing Hangers required. 5 Utilizes existing Wellhead Components. 5 5 5

5 5 5 5 5

Can be converted to 3 1/2, 2 7/8 or 2 3/8 EUE by simply changing the Mandrel. Lower Ring Gasket can be pressure tested. Virtually maintenance free. Can be adapted for thermal applications up to 210 C. Components are built to API specifications.

IPS WILL CUSTOM DESIGN AND BUILD TUBING ROTATORS TO MEET YOUR NEEDS ! COMPOSITE PUMPING TREE 5

Composite Pumping tree is third party supplied

5

Requires non-studded rotator

CONVENTIONAL WELLHEAD 5

Conventional Wellhead is third party supplied

5

Requires studded rotator

WELL ASSEMBLY

DOWNHOLE Prolongs Tubing Life 6-10 times. Paraffin build-up eliminated. (in most cases) Rod hang-up eliminated. (in most cases) Abnormal pump wear eliminated. Sand build-up in pump barrel Model CDHS eliminated. Downhole Swivel 5 Enhances corrosion inhibitors. 5 5 5 5 5

Model CRTA Rotating Tubing Anchor Catcher The CRTA Rotating Anchor Catcher allows the entire tubing string including the tailpipe and pump seating nipple to rotate while pulled into tension. This system is excellent on directional or horizontal wells where the anchor is to be set in the vertical section.

The CDHS Clutched Downhole Swivel Assembly is designed to be run in conjunction with the IPS Tubing Rotator on pumping wells that utilize a progressive cavity pump and an antirotation anchor.

Run with Anti-Rotation Anchor

Model JDHS Jay Latch Swivel The JDHS Jaylatch Down Hole Swivel is designed to be run in conjunction with the IPS Tubing Rotator on pumping wells that have a conventional anchor or packer in them.

Run on Beam Pump Wells

CONVENTIONAL TUBING HANGER

NO TUBING HANGER

MODIFIED TUBING HANGER

Run with Conventional Anchors & Packers

ROTATOR INSTALLATION

CTR TUBING ROTATOR 1). Screw Mandrel into the Tubing Hanger

4). Screw Handling Sub into Mandrel

2). Insert Mandrel/Hanger Assembly into the Wellhead

5). Pick up on Handling Sub and Unseat hanger

3). Lower Rotator onto Wellhead (FIGURE 1)

6). Install Catch Dogs and Optional Retaining Ring (FIGURE 2)

NOTE: ‘R’ ring gasket must be in place. If Hanger sits flush with wellhead as shown, use ‘RX’ ring gasket.

7). Lower Mandrel/Hanger Assembly so Catch Dogs take the weight

ON THE SURFACE MANUAL DRIVE

MECHANICAL DRIVE 5 5

Utilizes the Pump Jack No external power source required

5 Used on all types of installations

5 5

Used with Pump Jacks and P.C.P Pumps Three Phase, Single Phase, or 12 Volt (Hydraulic Drive is also available)

If Hanger is recessed, use standard “R” ring gasket.

8). At this point tubing can be rotated and the Tubing Hanger is unseated

IPS WILL LOWER YOUR PRODUCTION COSTS Contact your IPS Representative for more information INTEGRATED PRODUCTION SERVICES #1000, 840 - 7th Avenue SW Calgary, AB, Canada T2P 3G2 [Tel] 403.266.0908 [Fax] 403.266.1639 [Web] www.ipsl.ca

INTEGRATED PRODUCTION SERVICES #1000, 840 - 7th Avenue SW Calgary, AB, Canada T2P 3G2 [Tel] 403.266.0908 [Fax] 403.266.1639 [Web] www.ipsl.ca

ARTIFICIAL LIFT SYSTEMS

NOTE: Safety Shear Couplings are incorporated into each drive system, eliminating the possibility of over-torquing the tubing.

ARTIFICIAL LIFT SYSTEMS

ELECTRIC DRIVE