Split System Submittal Data - Panasonic

Report 3 Downloads 58 Views
Split System Submittal Data Indoor: CS-MKE9NB4U Multi System Indoor Units - Ceiling Recessed Job Name: Location: Engineer: Submitted to: Submitted by: Reference:

Approval: Date: Construction: Unit#: Drawing#:

General Data Power (V/P/Hz) Circuit Ampacity (A) Fuse Size, Max.(A) Running Amps (A) Power Input (W)

208 - 230/1/60 N/A 15 COOL .11 / .1 HEAT .13 / .12 COOL 15 / 16 HEAT 17 / 18

Indoor Unit

Cool/Heat

Fan type Dia & Length (in.) - No. Speeds No. Speeds No. Poles (RPM, High) No. Motors (W) CFM (HI) Operation Sound (HI/Med/Lo)

Turbo D12-5/8 L5-3/4 -1 3 & Auto 8 - 440/490 1-(23) 221/247 33/32/31-34/33/32

Coil Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq.ft.) Tube Size (in) Drain Connection Size

Aluminum Plate Fin & Copper Tube Aluminum - Copper 2 - 18.1 2.94 N/A 3/4

Refrigerant Line Size (in. O.D. Discharge) Line Size (in. O.D. Suction)

R410A 1/4” (Flare) 3/8” (Flare)

Dimensions (HxWxD) Indoor Unit (Crated) (in.) Indoor Unit (Uncrated) (in.)

11-13/32 x 24-13/16 x 28-1/8 12-5/16 x 24-19/32 x 24-19/32

Weight (lbs.) Net Shipping

35.3 41.9

Shipping Volume (cu.ft.)

4.59

12,300

Features Controls Remote Control Temperature Control Timer Night Setback Air Louver Power Failure Automatic Restart Self-Diagnosis Quiet Operation Air Filter

Microprocessor LCD Wirelss Built-in Temp Sensor IC Thermostat 24 Hr. Program, 1 Hr. Off Built-In Automatic Built-In Built-In Built-In Washable, Anti-Mold

Option

Performance Data @ ARI Standard Conditions (230V) Cooling Total Capacity (BTU/H) Moisture Removal (HI, Pint/H)

Heating Total Capacity (BTU/H)

9000 3.4

Refrigerant Line Set Fresh Air Intake Airduct Extension Condensate Drain Pump Hard Wired Remote Controller Non-Removeable Remo-con Bracket

Available Knock-out N/A Standard Available Available

Operating Range

Indoor Air Intake Temp

Outdoor Air Intake Temp

Cooling (Max) Cooling (Min) Heating (Max) Heating (Min)

95F DB/71F WB 67F DB/57F WB 80 F DB / 67 F WB - DB / - WB

115F DB 14F DB 75 F DB / 65 F WB

Indoor Dimensions

Indoor Unit

A

Fresh air intake duct connection port (dia. 3-7/8")

22-5/8 (575) 2-3/32 6-5/16 6-11/16

4-19/32 1-25/32

3-5/8

Less than 31/32

Less than 31/32

6

3

1-27/32

2-3/4

5-9/16

7-23/32

2-3/32

1-9/32

24-19/32 (625) 14-3/32 (358) 25/32

1-3/32

2

Unit : inch (mm)

Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon

7-11/16

8

A View

2

2

2 1

4-29/32

5

8-15/32

1-25/32

22-5/8 (575)

13-5/32 (334)

Suspension bolt hole (4 - 1/2" x 1-1/8" hole)

24-19/32 (625)

Power supply port

12-7/8

Refrigerant tubing (gas tube) dia. 1/2" (flared) Drain tube connection port VP20 (outer dia. 1")

The length of the suspension bolts should be selected so that there is a gap of 1-3/16" or the ceiling (21/32" or more below the lower surface of the main unit), as shown in the figure at right. If the suspension bolts is too long, it will contact the ceiling panel and the unit cannot be installed.

1-3/16

Refrigerant tubing (liquid tube) dia. 1/4" (flared)

3-1/8 21/32

Center of panel

7

1-3/16 (30)

Discharge outlet

11-5/32 (283)

Air intake

CS-KS12NB41 & CZ-18BT1U CS-KS18NB4UW & CZ-18BT1U

1 2 3 4 5 6 7 8

12-7/16 21-1/32 (534) Suspension bolt pitch 23-5/8 (600) Ceiling opening dimensions

23-5/8 (600) Ceiling opening dimensions 21-1/32 (534) Suspension bolt pitch