Split System Submittal Data Indoor: CS-ME7QKUA Multi System Indoor Units - Wall Mounted Job Name: Location: Engineer: Submitted to: Submitted by: Reference:
Approval: Date: Construction: Unit#: Drawing#:
General Data Power (V/P/Hz) Circuit Ampacity (A) Fuse Size, Max.(A)
230/208/1/60 15 15
Indoor Unit
Cool/Heat
Fan type No. Speeds RPM (High) Motor Output (W) CFM (Qlo/Lo/Me/Hi/SHi) cooling Indoor Sound Rating (Hi) (dB-A)
Cross Flow 5 1390 40 185/225/310/390/445 42 (low is 26)
Fin Type - Pipe Type Rows - F.P.I. Face Area (sq.ft.) Drain Connection Size (in.) Refrigerant Lbs. - R410a (outdoor unit) Control Connection Line Length, Max (ft.) Elevation Difference, Max (ft.) Line Size (in. O.D. Discharge) Line Size (in. O.D. Suction)
Features Wireless Remote Controller Wired Remote Controller (CZ-RD516C) Controls Remote Controller Temperature Control Air Louver, Horizontal Air Louver, Vertical Power Failure Autmoatic Restart Self-Diagnosis Air Filter
Standard Optional Microprocessor LCD Wireless Type IC Thermostat Manual Automatic Built-In Built-In Washable, One-touch
Performance Data @ ARI Standard Conditions (230/208V)
Operating Range
Indoor Air Intake Temp
Outdoor Air Intake Temp
Cooling Total Capacity (BTU/H) Sensible Capacity (BTU/H) Latent Capacity (BTU/H)