Mixing Reset Module 421

01/11 HVAC Systems Replaces: New

Job ___________________________

Designer_ ______________________

Contact_ _______________________

The Mixing Reset Module 421 is designed to operate all of the mechanical equipment in a hydronic heating system, except for zones, coordinating their operation through network communication. It can be used in applications ranging from a single zone of mixed radiant with an on/off boiler, to multiple radiant floor zones with an on/off boiler. This control regulates one mixed heating water temperature through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling a single on/off boiler, floating action or variable speed injection mixing, and can connect up to 24 zones in total.

Front View

Side View

Boiler

C

Item

/

1/2” Knock-out (x 16 back) (x 8 top) (x 8 bottom) (x 2 side)

Com Boil Mix Com Out 56 57 58 59 60 Do not apply power

Mixing Reset Module 421

Menu

H7007B

8–1/16” (204 mm)

Opn Cls

Floating Output: R R 24 V (ac) 8 VA 53 54 55 Powered Output

51 52

tN4

See Special Requirements Zone or Power Manager provides enclosure with NEMA rating 1.

tektra 99-02

Boil Sens Sup / Ret Off / Flushing Meets Class B: Canadian ICES & FCC Part 15 Made in Canada

Var. Pump: 115V (ac) 2.5 A Relay Rating: 115V (ac) 5 A

Test

61 62 Variable Speed Pump N

2.5 A

63 64 System P1 Pump N

7.5 A max

Var. Pump Fuse T2.5 A 250 V

7/16” (11 mm)

Ø 3/16” (5 mm)

CL 7/16” (11 mm)

11–1/8” (282 mm)

2–15/16” (74 mm)

Specifications------------------------------------------------------ Energy Saving Features-----------Mixing Reset Module 421 One tN4, Mixing Literature Control Packaged weight Dimensions Approvals Ambient conditions Power supply System P1 pump relay Variable speed pump Combined load Floating action output Boiler relay Demands Sensors –Included Warranty

D421, W421, J421, D070 Microprocessor control. This is not a safety (limit) control 1.6 lb (730 g) 3-5/8” H x 5-3/8” W x 9/16” D (92 x 137 x 14 mm) CSA C US, meets Class B: ICES & FCC Part 15 Indoor use only, 32 to 122°F (0 to 50°C), RH ≤80% to 88°F (31°C), down to 50% above 104°F (40°C), Altitude