kl high output - Columbia Lighting

Report 2 Downloads 68 Views
KL HIGH OUTPUT

Premium Industrial / 2, 3 or 4-Lamp T8, T12 PROJECT INFORMATION Project Name

Type

Catalog No.

Date

CONSTRUCTION

FEATURES

Heavy steel housing with longitudinal reinforcing ribs for extra strength.

• • • • • • •

White painted parts are treated with a five stage phosphate bonding process and finished with a high reflectance baked enamel. LSR and M4R reflectors specular room side, Mill finish aluminum top surface.

Available in 4' and 8' lengths Apertured reflectors have 15% uplight Spring loaded turret lampholders 6" lamp spacing For individual or continuous row mounting Channel ends double as joiners Full depth end closures available

FINISH

ELECTRICAL

Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. All ballast leads extend a minimum of 6" through access location. NEC/CEC-compliant ballast disconnect is standard.

ORDERING INFORMATION KL

EXAMPLE KL8-296HO-U-EPU-GLR



MODEL

SIZE

KL Premium Industrial

4 4' 8 8'

– NO. OF LAMPS IN CROSS SECTION 2 Two 3 Three 4 Four

ACCESSORIES (ORDER SEPARATELY) KZT Zip Tee Hanger - 1½" spacer on T-bar ceiling KTH Slide Clamp Tong Hanger S18 18" Stem, canopy and 8° aligner SS18 18", 45° Swivel Stem & Canopy KHC 24" Chain Hanging Assembly KLEC Full Depth End Closure KLWG4 Wire Guard 4' lg. - 2 required per 8' fixture KLEGG White Straight Blade Egg Crate Louver 4' - 2 required per 8' fixture OS1360K Occupancy/Daylight sensor kit, 120/277/347V, one relay, 360 Lens, snap on drop down adaptor, quick connect wiring1

CERTIFICATION

All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924.

EP



LAMP TYPE

REFLECTOR TYPE

48HO 4', T12: 60 Watt 96HO 8', T12: 110 or 95 Watt 96T8HO 8', T8: 86 Watt

U Apertured Reflector for Uplight ST Solid Top (No Uplight) M4RST Solid Top Reflector with 95% Reflective Specular Silver Finish M4RU Apertured Reflector with 95% Reflective Silver Finish

– OPTIONS

VOLTAGE U 120 277 347

120V-277V 120V 277V 347V

GLR GMF EL BC

Fast Blow Fuse Slow Blow Fuse Emergency Battery Pack Branch Circuit Plug-on Wiring System (See options section for details.) PAF Paint After Fabrication NYC NYC Compliant NYCU NYC Compliant, Union Label

BALLAST EP Electronic, Program Start For others available, see Ballast Options.

Use programmed start ballast. Not recommended for use with instant start. For more occupancy/daylight harvesting sensor accessories see Technical section.

1

Page 1/2 Rev. 08/27/14 © 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com

INDUSTRIALS / KL HIGH OUTPUT

KL HIGH OUTPUT

Premium Industrial / 2, 3 or 4-Lamp T8, T12

PHOTOMETRIC DATA

ZONAL LUMEN SUMMARY Zone

LUMINAIRE DATA

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

KL8-296HO-U KL Industrial 1' × 8' 2-L High Output Industrial w/White PAF Apertured Reflector 480-X-TC-P 0.95 F96T12/CW/HO 8800 252 N/A 0º = 1.26  90º = 1.26 Length: 8.00 Width: 1.02 Height: 0.00

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

3182 5250 9612 12738 535 780 1508 2364 15102

18.1 29.8 54.6 72.4 3.0 4.4 8.6 13.4 85.8

ENERGY DATA

21.1 34.8 63.6 84.3 3.5 5.2 10.0 15.7 100.00

INDOOR CANDELA PLOT

RCR

70 90 81 74 67 62 57 53 49 46 43

80 50 30 86 82 74 68 65 58 57 49 51 43 45 38 41 34 37 30 34 27 31 25

10 78 63 52 44 37 32 28 25 22 20

70 86 78 71 64 59 54 50 47 44 41

70 50 30 82 79 71 66 62 56 55 48 49 42 44 37 40 33 36 29 33 27 31 24

10 76 61 51 43 36 32 28 25 22 20

50 76 66 58 51 46 41 37 34 31 29

50 30 73 62 52 45 40 35 31 28 25 23

10 71 58 48 41 35 30 27 24 21 19

85.8%

Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

57 Non-Compliant $4.21 based on 3000 hrs. and $0.08 per KWH

AVG. LUMINANCE (Candela/Sq. M.)

COEFFICIENTS OF UTILIZATION (%) RC RW 1 2 3 4 5 6 7 8 9 10

Total Luminaire Efficiency

Average Luminance Angle

Luminaire

Test 10244 Test Date 1/8/03

Lumens % Lamp % Fixt.

0 0 59 49 41 34 30 26 23 20 18 16

0 30 40 45 50 55 60 65 70 75 80 85

0.0

22.5

45.0

67.5

90.0

5457 5359 5283 5223 5143 5037 4889 4694 4428 4062 3570 2815

5457 5237 5166 5128 5085 5020 4957 5019 5141 4888 4740 4056

5457 5292 5297 5330 5483 5660 5633 5500 5419 5912 4923 3905

5457 5340 5467 5680 5967 5754 5651 5621 6098 6065 3836 4147

5457 5330 5550 5779 5877 5747 5667 5706 6368 5836 3631 4253

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

DIMENSIONAL DATA

MOUNTING ACCESSORIES 96" 861/16"

2"

2"

11/8" 15/16" 431/32"

48" 2"

48" 381/16"

2"

15/16" 11/8" 381/16" 431/32"

KHC

S18

43/16"

61/8" 35/8" 6" 133/8" KZT

KTH

A: 7/8" Diameter knockout B: .570" × .656" Strain Relief knockout E: 11/8" Diameter knockout NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.

Page 2/2 Rev. 08/27/14 © 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com

INDUSTRIALS / KL HIGH OUTPUT