Assembly Instructions
Shelter type: SR1555 www.shelters4less.co.uk
[email protected] 0800 160 1002
SR1555-01-150116-UK
Exploded View of Shelter 10
5
13 11
12
13 9
10
13
12
9
8
2
7
1
6
1
3
2 6
14
5 14
14
4 14
14 14 Tools required:
3 Tools included:
Drill/Screwdriver
Wrench
Mallet
Torx bit
Hack saw
2
PARTS LIST AND FIXINGS ITEM PART DESCRIPTION DIMENSIONS NO. NO.
IMAGE
QTY.
1
S1
Frame
2000 x 1035
7
2
S3
Frame
2000 x 517
1
3
P1
Post
2000
1
4
ST5
Roof Tie
1543x40x40
1
5
CB1
Bracket
110 x 110 x 40
7
6
JF1
Bracket
220 x 40
10
7
RB2
Bracket
110 x 46
12
8
R2
Rafter
2199
4
9
SS
Sealing Strip
Trim to 2220
8
10
PCE2
Roof Panel
2220 x 1050
2
11
PCC2
Roof Panel
2220 x 1030
1
12
RC2
Roof strip
2180
4
13
2MD
Roofing Edge trim
1572.5
4
14
FT1
Bracket
109 x 100 x 3
10
15
EC40
Plastic End Cap
40 x 40
12
Fittings Bolt set M10
Pack A+B Required Spare
T25
T50
25 mm 50 mm Black Tech screw screw Caps
M10 x 60mm
Nut
33
33
66
136
40
5
5
10
64
8
28
28
Washer Tech
56
72
Image
3
32
66 56 10
BTANCM12100 M10/12 x 100 mm Concrete Bolt
11 8
3
Step 1 Assemble S1 frames to make up the main structure using CB1 brackets for the Corners and JF1 brackets for the straight joints.
10
21
Please note 50mm Tec Screws are for roof panels only
CB1
JF1
JF1
S1
S1
CB1
45
JF1
CB1 JF1
31
JF1
CB1
JF1
S1
S1 MEASURE THE WIDTH AND DEPTH OF THE SHELTER TO CHECK CORRECT ALIGNMENT. S1
CB1
JF1
JF1 JF1
CB1 Ensure corect alignment on all corners
CB1
4
Step 2 Attach P1 post using a JF1 bracket then use two JF1 brackets to attach S3 frame. The ST5 tie bar is mounted using a CB1 and a JF1 bracket. Make sure the structure is square then move the shelter to its final location before using the FT1 foot brackets to secure it to the ground.
JF1
CB1 JF1
ST5 FT1 S3
P1
FT1
ST5
S3
P1
5
Step 3 Attach R2 rafters using RB2 brackets. R2
RB2
R2 RB2
R2
RB2
RB2
RB2
RB2
RB2 RB2
1035 R2
1035 R2
ENSURE CORRECT ALIGNMENT OF RAFTERS
SIDE VIEW
R2
6
Step 4 Stick sealing strips (SS) to the rafters. Align the PCE2 roof panels with the outer roof rafters and equaly space the PCC2 panel in the middle.
PCE2 PCC2 PCE2 SS SS
SS
SS
7
Step 5
Screw down the RC2 strips as shown below. Then apply the 2MD edge trim to the bottom edges of the roof panels. RC2 2MD
RC2 RC2 2MD
2MD
RC2
2MD
RC2
RC2
RC2
RC2
2MD
8
2MD
Notes:
9
Notes:
10
PLAN VIEW OVERALL DIMENSIONS AND GROUND FIXING POSITIONS Suggested size for concrete base: 200mm oversized on all 4 sides.
1035
112
1533
1035 938
3145
477
1035
981
935
113
995
1035 2209
11
THANK YOU FOR PURCHASING THIS PRODUCT
MAINTENANCE: To ensure your products give you many years of use we recommend that you: • • •
Clean panels regularly with soapy water Ensure all fittings are tight (for example after a big storm) Touch up any exposed metal should it get scratched
CONTACT DETAILS: Email :
[email protected] Web : www.shelters4less.co.uk Tel : 0800 160 1002 Shelters4Less, Unit 3, 2 Landsdowne Crescent, Bournemouth, BH1 1SA
All Parts and Fixings checked by: Print Name:
Signature:
12