Curv Perforated Housing - Alera Lighting

Report 3 Downloads 70 Views
Cûrv Perforated 1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution

CHIT

S

SORS

AR

C

Project Name

Type

Catalog No.

Date

EN

E

Project Information TURAL

Construction

Labels and Electrical

—Up to four T8 lamps and up to three T5 or T5HO lamps.

— Quick-connect plugs standard.

—Housing provides indirect distribution. Glow from perforation allows under 5% direct light.

Features

• 2½" deep housing for a sleek modern appearance • Indirect Luminaire • Unique lamp crossing technique on one and three lamp models maintains 48" modularity • Heavy 20-gauge steel construction provides excellent housing rigidity • Controls compatible • Available with optional installed open or closed loop daylight sensors (DSPL, DSL) when daylight dimming systems are desired • Unique die cast aluminum, tongue and groove couplers provide zero tolerance alignment resulting in consistently straight rows • Patented die cast aluminum end caps for a soft finished appearance (Patent# 6,796,676B2) • Flat end caps standard • Available with a slotted or perforated housing • Modular mounting points for convenient hanging locations • Available with exclusive wiHUBB technology preinstalled (WIH option) – Peer to peer, self-healing wireless mesh network – Integrated control system for 0-10VDC or step dimming, or On/Off

—All luminaires are built to UL1598 Standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard.

—The exact shape of the housing is maintained by the use of an inner die cast plate at each fixture end.

—Reflectors: standard with a painted white steel reflector with specular inserts on the side.

architectural sensors installed

—High efficiency reflector (HRF) high reflectance specular material allows for wide distribution with maximum efficiency.

Daylight sensors are used to measure available sunlight and reduce electric light for energy savings. Alera sensors are installed to be both accessible and visible below the housing.

—WR: An economical painted white reflector

9½"

The housing and all painted parts are treated with a multi-stage phosphate bonding process before being finished. Parts are then finished with a white RAL powder coat finish for maximum consistent coverage and longevity. —Aircraft cable suspension mechanism.

Additional technical data: see TID sheets, Alera website and sensor manufacturer websites.

Name: Test #: Efficiency: LER:

Housing type PERF Perforated HSLT Horizontal Slot Strip VLST Vertical Slot Strip LAMP TYPE AND PROFILE 1T5 One T5 Lamp 2T5 Two T5 Lamps 3T5 Three T5 Lamps 1T5HO One T5HO Lamp 2T5HO Two T5HO Lamps 3T5HO Three T5HO Lamps 2T8 Two T8 Lamps 3T8 Three T8 Lamps 4T8 Four T8 Lamps

Specify voltage. For additional, specify quantity before nomenclature (Example: 2EL120). Not available with all configurations; some limitations apply. Contact factory for details. 3 One extra feed drop per EMC or NLC. (For through wiring, contact factory.) 4 Lutron EcoSystem® series ballast. Contact factory for other Lutron ballasts. 5 Ships separately. 1

2

Page 1/4 Rev. 06/30/13

CV-1T8-S-E-WR 12991 97.2% 86

Example: CV-8-2T8-PERF-CM48-EU-MW



Row length 4' Single 8' Single 12' Single Indicate row length over 12' in 4' increments Note: Rows over 12' will be configured by Alera. Example: 16' will be (2) 8'. Alternate configurations: contact factory. 4 8 12 —

DSL: Lutron EcoSystem, digital dimming ballast. Open loop sensor must be pointed directly at the source of natural light. System requires proprietary commissioning by others.

Mounting

Ordering Information

Model CV Cûrv

DSPL: Philips Luxsense, Mark 7 0-10V dimming ballast. Closed loop sensor measures reflected light in a cone below the sensor. Pre-commissioned by Philips to 45fc standard; modest manual adjustability via sensor ring.

Finish

End of cable barrel screws into a standard ¼-20 bolt brought down from the ceiling. A feed canopy is provided for each feed location. All fixtures are suspended in modular increments and must be supported at each fixture-housing end.

2½"



Controls compatible. When used with Occupancy Sensors, most lamp vendors recommend Program Start ballast (EP) to extend lamp life. Common control schemes: wiHUBB Enabled (WIH) switching (L/R or IBOB), 0-10V dimming ballast (ED), Step Dimming ballast (ESD), wiHUBB Enabled (WIH). Compatibility with specific control (example, dimmer switch) is by others. wiHUBB antenna will be visible. For daylight sensors installed, see information below.

—The housing is designed to wrap around the end plates and secures on top with concealed screws to ensure housing tolerances are consistent. These die cast aluminum end caps and aligners provide zero tolerance alignment between fixtures, resulting in consistently straight rows with no snaking.

—Fixed cable has a total vertical adjustment of 1¼".

Shape and Dimensions

CV —

controls compatibility

— MOUNTING Method FCM18 Fixed Aircraft Cable Mount (Non-adjustable, Std.) 18" CM Adjustable Aircraft Cable Mount

— Adjustable Cable length 48 48" 96 96" Other lengths available on request.

Ballast E Electronic, Instant Start (Std. for T8) EP Electronic, Programmed Start (Std. for T5 & T5HO, optional for T8) ELW Electronic T8, Low Wattage, Instant Start EPLW Electronic T8, Low Wattage, Programmed Start ED Electronic, Dimming (Must specify) ESD Electronic, Step Dimming EDUMK7 Universal Voltage, Electronic Dimming Philips Advance Mark 7 (0-10V) EDULUTES Universal Voltage, Lutron EcoSystem Digital Dimming Ballast 2, 4 Unless specified, Alera will use fewest ballasts possible.

— U 120 277 347

Voltage 120V-277V 120V 277V 347V



Finish MW Matte White (Std.) ZT ZET Metallic Silver See Color Selection Guide for other colors. Options

WR HRF DC SCE BN LR IBOB F0841 F5841 F0835 F5835 EL EMC NLC GLR GMF TBAR WIH DSPL

White Reflector High Efficiency Reflector Dust Cover (N/A T5HO)5 Sculpted End Cap (55⁄16")5 Bull Nose End Cap (51⁄16")5 Left/Right Switching (2-Lamp only) Inboard/Outboard Switching (3-Lamp only) With T8 4100L Lamp Installed With T5(HO) 4100K Lamp Installed With T8 3500K Lamp Installed With T5(HO) 3500K Lamp Installed One Emergency Battery Pack1, 2 One Emergency Circuit 2, 3 Night Light Circuit 2, 3 Fast Blow Fuse Slow Blow Fuse T-Bar Mounting wiHUBB Enabled 2 Philips LuxSense Daylight Sensor (Must Specify Philips Advance 0-10V Dimming Ballast)2 DSL Lutron Daylight Sensor (Must Specify Lutron EcoSystem (EC5 Series)Dimming Ballast)2, 4

Protected by US Patent 6,796,676. Protected by Canada Patent 2,450,528. Specifications subject to change without notice.

© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Curves / CV PERF

Cûrv Perforated 1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution Cross section 2½"

2½"

9½" CV-2T8 PERF

2½"

9½" CV-3T8 PERF

9½" CV-4T8 PERF

2½"

2½"

9½" CV-1T5, T5HO PERF

2½"

9½" CV-2T5, T5HO PERF

9½" CV-3T5, T5HO PERF

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

CV-2T8-PERF-CM-E Cûrv Architectural Curve 9.5" × 48" 2-Lamp with LS Side Reflector REL2P32SC 0.87 F32T8 2900 59 Pendant 0º = 90  90º = 90 0º = 1.16  90º = 1.31 Length: 3.54 Width: 0.33 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

369 330 301 274 244 225 203 174 189 178 159 211

369 351 325 300 287 273 258 283 296 320 425 634

369 362 349 352 387 386 387 392 431 498 584 952

369 369 372 372 397 409 430 443 444 459 450 482 461 498 480 523 539 566 605 676 743 796 1269 1374

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 31 51 93 133 1775 2680 4286 5421 5555

0.5 0.9 1.6 2.3 30.6 46.2 73.9 93.5 95.8

0.6 0.9 1.7 2.4 32.0 48.3 77.2 97.6 100.0

RCR

Luminaire

Angle

Luminaire Data Test 13197

RC RW 1 2 3 4 5 6 7 8 9 10

70 83 76 69 63 58 53 48 45 41 38

80 50 30 80 76 69 64 61 54 54 47 47 40 42 35 38 31 34 27 31 24 28 21

10 73 59 49 41 35 30 26 22 20 17

70 71 65 59 54 49 45 41 38 35 33

70 50 30 68 66 60 55 52 47 46 40 41 35 36 30 33 27 29 24 26 21 24 19

10 63 52 43 36 31 26 23 20 17 15

50 47 41 36 32 28 25 23 21 19 17

50 30 46 39 33 29 25 22 19 17 15 13

10 44 36 30 26 22 19 16 14 12 11

Indoor Candela Plot 0 0 2 1 1 1 1 1 1 1 1 0

180 165 1500

150

120 750 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75 750

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

95.8% 82 Yes-VDT Intensive Use $2.93 based on 3000 hrs. and $0.08 per KWH

135

60 1500 0

15 30 Horiz 0-180 90.0 45.0

0.0

45

Test Date 8/22/02

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

CV-2T8-PERF-E-HRF Cûrv Architectural Curve 9.5" × 48" 2-Lamp with Perforated Highly Specular Reflector B232I120RH-A 0.88 F32T8 2900 59 Pendant 0º = 90  90º = 90 0º = 1.09  90º = 1.09 Length: 3.54 Width: 0.33 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

101 85 84 78 72 64 55 44 0 0 0 0

101 74 60 52 57 48 37 44 27 0 0 0

101 74 72 78 72 64 74 65 54 36 0 0

101 85 84 91 86 96 92 87 81 71 53 0

101 85 84 91 86 96 92 87 81 71 53 106

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 7 12 20 32 1871 2898 4499 5337 5369

0.1 0.2 0.3 0.6 32.3 50.0 77.6 92.0 92.6

0.1 0.2 0.4 0.6 34.8 54.0 83.8 99.4 100.0

RCR

Luminaire

Angle

Luminaire Data Test 12982

RC RW 1 2 3 4 5 6 7 8 9 10

70 80 73 66 61 55 51 47 43 40 37

80 50 30 77 73 67 62 59 52 52 45 46 39 41 34 36 30 33 26 29 23 27 21

10 70 57 47 40 34 29 25 21 19 16

70 68 62 57 52 47 43 40 37 34 32

70 50 30 66 63 57 53 50 45 44 39 39 34 35 29 31 26 28 23 25 20 23 18

10 60 50 41 35 29 25 22 19 16 14

50 45 39 35 31 27 24 22 19 18 16

50 30 43 37 31 27 24 21 18 16 14 13

10 42 35 29 24 21 18 15 13 12 10

Indoor Candela Plot 0 0 0 0 0 0 0 0 0 0 0 0

180

165

150

120 850 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75 850

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

135

1700

60 92.6% 80 Yes-VDT Intensive Use $3.00 based on 3000 hrs. and $0.08 per KWH

1700 0 0.0

15 30 Horiz 0-180 90.0 45.0

Page 2/4 Rev. 06/30/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

45

Test Date 12/12/01 Curves / CV PERF

Cûrv Perforated 1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

CV-3T8-PERF-E-HRF Cûrv Architectural Curve 9.5" × 48" 3-Lamp with Perforated Highly Specular Reflector B332I120RHA 0.88 F32T8 2900 88 Pendant 0º = 90  90º = 90 0º = 1.19  90º = 1.01 Length: 3.54 Width: 0.33 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

313 287 277 274 258 225 203 174 162 142 106 211

313 245 217 208 201 209 203 196 189 178 212 211

313 234 241 248 258 241 258 262 269 285 318 423

313 245 265 274 272 289 295 305 323 320 371 529

313 255 265 274 287 305 295 327 323 356 425 634

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 23 37 66 98 2312 3778 6361 7757 7855

0.3 0.4 0.8 1.1 26.6 43.4 73.1 89.2 90.3

0.3 0.5 0.8 1.3 29.4 48.1 81.0 98.7 100.0

RCR

Luminaire

Angle

Luminaire Data Test 12985

RC RW 1 2 3 4 5 6 7 8 9 10

70 78 71 65 59 54 50 46 42 39 36

80 50 30 75 71 65 60 57 51 50 44 45 38 40 33 35 29 32 25 29 23 26 20

10 69 56 46 39 33 28 24 21 18 16

70 67 61 55 50 46 42 39 36 33 31

70 50 30 64 61 56 52 49 44 43 38 38 33 34 29 31 25 27 22 25 20 23 18

10 59 48 40 34 29 25 21 18 16 14

50 44 39 34 30 27 24 21 19 17 16

50 30 43 36 31 27 23 20 18 16 14 12

10 41 34 28 24 20 17 15 13 11 10

Indoor Candela Plot 0 0 1 1 1 0 0 0 0 0 0 0

180

165

150

135

2400 120 1200 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75 1200

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

90.3% 79 Yes-VDT Intensive Use $3.04 based on 3000 hrs. and $0.08 per KWH

60 2400 0

15 30 Horiz 0-180 90.0 45.0

0.0

45

Test Date 12/4/01

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

CV-1T5HO-PERF-CM-EP Cûrv Architectural Curve 9.5" × 48" 1-Lamp with LS Side Reflectors ICN2S54 1.00 F54T5 4400 63 Pendant 0º = 90  90º = 90 0º = 1.13  90º = 1.30 Length: 3.54 Width: 0.33 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

295 255 241 222 186 177 147 131 135 142 159 211

295 266 253 235 215 209 184 196 216 214 265 423

295 277 277 274 287 305 295 305 296 320 371 634

295 287 313 326 344 353 350 371 404 427 478 846

295 298 325 339 358 369 369 392 404 463 584 952

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 24 40 72 101 1617 2295 3461 4259 4360

0.6 0.9 1.6 2.3 36.8 52.2 78.7 96.8 99.1

0.6 0.9 1.7 2.3 37.1 52.7 79.4 97.7 100.0

RCR

Luminaire

Angle

Luminaire Data Test 13188

RC RW 1 2 3 4 5 6 7 8 9 10

70 86 78 71 65 60 55 50 46 43 40

80 50 30 82 79 72 66 63 56 55 48 49 42 44 36 39 32 35 28 32 25 29 22

10 75 62 51 43 36 31 27 23 20 18

70 74 67 61 56 51 47 43 40 37 34

70 50 30 71 68 62 57 54 49 48 42 42 36 38 31 34 28 30 24 27 22 25 19

10 65 53 44 37 32 27 23 20 18 16

50 49 43 38 33 29 26 24 21 19 18

50 30 47 40 34 30 26 22 20 17 15 14

10 46 38 31 27 23 19 17 15 13 11

0 0 2 1 1 1 1 1 1 1 1 0

Indoor Candela Plot 150 135 180 165 1200 120 600 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75 600

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

99.1% 69 Yes-VDT Intensive Use $3.48 based on 3000 hrs. and $0.08 per KWH

60 1200 0 0.0

15 30 Horiz 0-180 90.0 45.0

Page 3/4 Rev. 06/30/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

45

Test Date 9/13/02

Curves / CV PERF

Cûrv Perforated 1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

CV-1T5HO-PERF-EP-HRF Cûrv Architectural Curve 9.5" × 48" 1-Lamp with Perforated Highly Specular Reflector QT1X54/120PHO 1.00 F54T5 4400 61 Pendant 0º = 90  90º = 90 0º = 1.46  90º = 1.53 Length: 3.54 Width: 0.33 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

28 32 24 26 29 32 37 22 27 36 53 106

28 32 24 26 29 32 37 22 27 36 53 106

28 32 36 39 43 32 37 44 54 36 53 106

28 32 36 39 43 38 37 44 54 71 53 106

28 32 36 39 43 32 37 44 54 71 53 106

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 3 4 8 13 1965 2761 3818 4351 4364

0.1 0.1 0.2 0.3 44.7 62.8 86.8 98.9 99.2

0.1 0.1 0.2 0.3 45.0 63.3 87.5 99.7 100.0

RCR

Luminaire

Angle

Luminaire Data Test 12987

RC RW 1 2 3 4 5 6 7 8 9 10

70 86 78 71 65 59 54 50 46 43 40

80 50 30 82 78 72 66 63 56 55 48 49 42 43 36 39 32 35 28 32 25 29 22

10 75 61 51 43 36 31 27 23 20 18

70 73 67 61 55 50 46 43 39 36 34

70 50 30 70 67 61 57 54 48 47 42 42 36 37 31 33 27 30 24 27 21 25 19

10 65 53 44 37 31 27 23 20 18 15

50 48 42 37 33 29 26 23 21 19 17

50 30 46 39 34 29 25 22 19 17 15 13

10 45 37 31 26 22 19 16 14 12 11

Indoor Candela Plot 0 0 0 0 0 0 0 0 0 0 0 0

180 165 1700

150

135

120 850 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75 850

Energy Data

60

Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

99.2% 72 Yes-VDT Intensive Use $3.33 based on 3000 hrs. and $0.08 per KWH

1700 0 0.0

15 30 Horiz 0-180 90.0 45.0

45

Test Date 12/18/01

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

CV-2T5HO-PERF-EP-HRF Cûrv Architectural Curve 9.5" × 48" 2-Lamp with Perforated Highly Specular Reflector QT2X54/120PHO 1.00 F54T5 4400 121 Pendant 0º = 90  90º = 90 0º = 1.33  90º = 1.23 Length: 3.54 Width: 0.33 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

64 64 60 65 72 64 55 44 54 71 53 106

64 53 60 65 57 48 55 65 54 71 106 106

64 64 60 65 72 80 92 87 81 71 106 211

64 64 72 78 86 80 92 87 108 107 106 211

64 64 72 78 86 80 92 109 108 107 159 211

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 6 9 17 26 3241 4994 7407 8584 8610

0.1 0.1 0.2 0.3 36.8 56.7 84.2 97.5 97.8

0.1 0.1 0.2 0.3 37.6 58.0 86.0 99.7 100.0

RCR

Luminaire

Angle

Luminaire Data Test 12933

RC RW 1 2 3 4 5 6 7 8 9 10

70 85 77 70 64 59 54 49 45 42 39

80 50 30 81 77 71 65 62 55 54 47 48 41 43 36 38 31 34 27 31 24 28 22

10 74 61 50 42 36 30 26 23 20 17

70 72 66 60 54 50 46 42 39 36 33

70 50 30 69 66 60 56 53 48 47 41 41 35 37 31 33 27 30 24 27 21 24 19

10 64 52 44 37 31 26 23 20 17 15

50 47 41 36 32 29 25 23 21 19 17

50 30 46 39 33 29 25 22 19 17 15 13

10 44 37 31 26 22 19 16 14 12 11

Indoor Candela Plot 0 0 0 0 0 0 0 0 0 0 0 0

180 165 3200

150

120 1600 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75 1600

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

135

60 97.8% 71 Yes-VDT Intensive Use $3.38 based on 3000 hrs. and $0.08 per KWH

3200 0 0.0

15 30 Horiz 0-180 90.0 45.0

Page 4/4 Rev. 06/30/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

45

Test Date 8/31/01

Curves / CV PERF