M STG Wall MounT

Report 3 Downloads 99 Views
M STG Wall Mount 1 or 2-Lamp, Staggered Lamps, Direct Symmetric Project Information Project Name

Type

Catalog No.

Date

Construction Extruded aluminum housing includes typical recycled content of 25-30%. END CAPS Features • 3½" × 3½" rectilinear beam appears to float just off vertical surface of wall • ADA compliant • 1 or 2 T5 or T5HO • Extensive aesthetic options • Symmetric downlight distribution with a wide choice of shieldings • Available with optional light modules • Staggered lamps to create continuous, unbroken rows of light • Full family including cable mount, wall mount, surface mount and recessed • Companion fixtures include the 2½" × 3½" Microlyne® Mini and 3½" × 5" Microlyne® DirectIndirect • Aesthetic continuity across family, shielding and options • Available with exclusive wiHUBB technology preinstalled (WIH option) – Peer to peer, self-healing wireless mesh network – Integrated control system for 0-10VDC or step dimming, or On/Off • Patented clips for louver retention (Patent #8,142,048)

Shape and Dimensions

Die cast flat end caps for standard lamp configuration. Both end caps feature silicone gasket to eliminate light leak, see Light Seal. Ships installed on fixture. Light seal

Housing unions between all joints include upper formed light seal and aligner connectors to block light. End of row and single units feature unique optimized V-0 closed cell silicone gasket light seal at joints between extruded housing and die cast end cap. CONNECTIONS

Secure, simple housing connections ensure row continuity. Standard lamp configuration features patent pending Ready Connect system for end cap connections. MOUNTING

Microlyne® Wall Mount uses cleverly designed, ADA compliant, discreet wall brackets to create a floating appearance approximately ½” from the vertical wall surface. Brackets are made with heavy gauge galvanized steel.

4 8 12 __

— STG —

Row length 4' Single 8' Single 12' Single Indicate row length in 4' increments.1

Lamp stagger STG Staggered

Model M Microlyne

Row pattern Blank Straight P Pattern (specify) Pattern layouts require factory approval drawings.

LAMP TYPE AND PROFILE 1DT5 One T5 Lamp 2DT5 Two T5 Lamps 1DT5HO One T5HO Lamp 2DT5HO Two T5HO Lamps

Symmetric downlight distribution is standard and used for general purpose lighting where uniform distribution is desired. Asymmetric downlight louver also available; see MA STG WM specification sheet. ELECTRICAL

—All luminaires are built to UL1598 standards and bear the appropriate cUL or CSA labels. Damp location listed. —Quick connect plugs standard. FINISH

SHIELDING

CONTROLS COMPATIBILITY

WCB – White Cross Baffle emphasizes linearity with a crisp, clean bladed appearance.



DISTRIBUTION

High reflectance formed white reflector.

Ordering Information

M —

HEP - High efficiency specular parabolic louvers maximize downlight for enhanced efficiency where maximum light output is the primary concern.

Matte White powder coat standard for end caps and housing. Zet Silver and additional colors and finishes optional.

OA - Opal Acrylic lens emphasizes the narrow rectilinear shape by creating a pleasant glow of white along the underside of the housing.

4"

M4R - 95% Reflective Specular Aluminum louvers combine glare control and performance with a high tech, cubed aesthetic.

REFLECTOR

Shielding is provided for single or continuous row. 3½"

MA - Matte anodized louvers incorporate an attractive but subtle grain pattern which minimizes the visibility of fingerprints and construction dust without sacrifice to aesthetic qualities.

Controls compatible. When used with occupancy sensors, most lamp vendors recommend program start ballasts (EP) to extend lamp life. Common control schemes: wiHUBB enabled (WIH) switching L/R, 0-10V dimming ballast (ED), Step Dimming ballast (ESD), wiHUBB enabled (WIH). Compatibility with specific control is by others. wiHUBB antenna will be visible.

Example: M-16-STG-1DT5-WM-WCB-EP120-MW-EL

— WM — Mounting WM Wall Mount

downlight shielding OA Opal Acrylic Lens WCB White Cross Baffle MA Matte Anodized Low Iridescent SemiSpecular Aluminum Louver (24 Cell) M4R 95% Reflective Specular Aluminum Louver (24 Cell) HEP High Efficiency Parabolic Specular Louver (15 Cell)

— Voltage U 120V277V 120 120V 277 277V 347 347V

— Color MW Matte White (Std.) ZT ZET Metallic Silver See Color Selection Guide for other colors.

Ballast EP Electronic, Programmed Start (Std. for T5 & T5HO) ED Electronic, Dimming (Must Specify)2

— Light module 2, 3 MR16D MR16 Downlight Module

— # Light Modules 3 1M One 2M Two 3M Three 4M Four

Options LR Left/Right Switching (2-Lamp only) EL 1 Emergency Battery Pack Per Row2, 4, 6 EMC One Emergency Circuit NLC Night Light Circuit2, 4, 6 GLR Fast Blow Fuse GMF Slow Blow Fuse WIH wiHUBB Enabled4

Rows over 12' will be configured by Alera. Example: 16' will be (2) 8'. For alternate configurations, contact factory. Specify dedicated voltage. Not available with all configurations; some limitations apply. Contact factory for details. 4 One extra feed drop per EMC/NLC. For through wiring, contact factory. 5 For additional, specify quantity before nomenclature (Example: 2EL120, EMC277). 1 2 3

Page 1/2 Rev. 06/18/13

US and Canada Patents Pending. Specifications subject to change without notice.

© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Beams / M STG WM

M STG Wall Mount 1 or 2-Lamp, Staggered Lamps, Direct Symmetric Cross section

Plaster Ring (Supplied By Others)

Louver

Symmetric Louver ½"

Baffle

3½"

1T5 Staggered

Opal Acrylic Lens

3½" 4"

2T5 Staggered

M4R

White Cross Baffle

1T5

HEP

Photometric Data Luminaire Data Test 14885 Luminaire

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle

Zonal Lumen Summary Zone

M-1T5-HEP-EP Microlyne® Beams 3.5" × 48" 1-Lamp with 15 Cell Louver ICN-2S28 1.04 F28T5 2600 33 0º = 19  90º = 33

0-30 0-40 0-60 0-90 0-180

850 1388 2145 2222 2222

32.7 53.4 82.5 85.5 85.5

RCR

80 50 30 93 90 83 79 75 70 68 62 62 55 56 49 51 45 47 41 43 37 40 34

10 87 75 65 57 50 45 40 36 33 30

70 93 87 80 75 69 64 60 56 53 49

50 91 82 74 67 61 55 51 46 43 40

70

30 88 78 69 61 55 49 44 40 37 34

10 86 74 65 57 50 44 40 36 33 30

50 87 79 72 65 59 54 49 45 42 39

50 30 85 76 67 60 54 48 44 40 36 33

10 83 73 64 56 49 44 40 36 32 30

Indoor Candela Plot

0.0

75

0 0 77 68 60 53 47 42 38 34 31 28

550 60

0 11474 30 11124 40 10524 45 9788 50 8674 55 7112 60 4629 65 2980 70 1164 75 42 80 0 85 0

22.5

11474 11522 10707 9940 8842 7169 4908 2802 1039 42 0 0

45.0

11474 11522 10890 9971 8473 6381 4026 1808 661 208 0 0

67.5

11474 11845 10749 9210 6916 4204 1765 484 126 42 0 0

90.0

11474 11907 10454 8707 6263 3284 904 127 63 42 0 0

1100 15

0

0.0

4' (Non-STG) 8' 12' 16' 20' 24' 28' 32' 48'

Candela Summary 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Row Length 4' 8' 12' 16' 20' 24' 28' 32' 48'

Comparative Yearly Lighting Energy Cost per 1000 Lumens

Angle

70 96 89 82 76 71 66 61 57 54 50

85.5% 70 Yes - VDT Normal Use $3.43 based on 3000 hrs. and $0.08 per KWH

Total Luminaire Efficiency Luminaire Efficacy Rating (LER) IESNA RP-1-2004 Compliance

38.3 62.5 96.5 100.0 100.0

Coefficients of Utilization (%) RC RW 1 2 3 4 5 6 7 8 9 10

Energy Data

Lumens % Lamp % Fixt.

1T5

30 Horiz 0-180

45.0

45

Test Date 2/5/08

90.0

Microlyne® Staggered Lamp Configuration (1) 4' (3) 3' (1) 2' (3) 3' (1) 4' (4) 3' (2) 4' (1) 2' (5) 3' (2) 4' (6) 3' (3) 4' (1) 2' (7) 3' (3) 4' (8) 3' (4) 4' (12) 3' (6) 4'

Row Length 4' 8' 12' 16' 20' 24' 28' 32' 48'

2T5

Lamp Configuration (2) 4' (4) 4' (6) 4' (8) 4' (10) 4' (12) 4' (14) 4' (16) 4' (24) 4'

Page 2/2 Rev. 06/18/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Beams / M STG WM